文献速递肿瘤 PET/CT

整合人工诊断的影像组学列线图降低肺癌疑似患者18F-FDG PET/CT假阳性率

Integrating manual diagnosis into radiomics for reducing the false positive rate of 18F-FDG PET/CT diagnosis in patients with suspected lung cancer.
PubMed 文献 · Eur J Nucl Med Mol Imaging · 2019-07-18

结果显示人工诊断假阳性率为30.6%,混合列线图在训练集和测试集的假阳性率分别为5.4%和9.1%,AUC分别为0.98和0.92,且未显著牺牲敏感性。

要点

  • 人工诊断假阳性率为30.6%,混合列线图在训练集和测试集假阳性率分别降至5.4%和9.1%。
  • 混合列线图分别纠正了PET/CT影像组学特征所致假阳性病例的78.6%和37.5%,未显著牺牲敏感性。
  • 混合列线图在训练集和测试集AUC分别为0.98和0.92,Youden指数分别为85.8%和75.5%。

核心结论

  • 整合PET/CT影像组学特征与人工诊断的混合列线图可显著降低假阳性率、提高诊断准确性并增强临床获益。
  • 整合人工诊断后混合列线图性能优于单独PET/CT影像组学特征,提示临床医生判断是改进影像组学诊断方法的重要信息来源。

研究设计与样本

  • 回顾性纳入3947例18F-FDG PET/CT筛查的肺部病变患者中的157例恶性和111例良性患者,分为训练集和测试集。
  • 从CT、薄层CT、PET和PET/CT提取4338个特征,经LASSO方法生成四种影像组学特征。
  • 采用多变量逻辑回归构建整合影像组学特征与人工诊断的影像组学预测列线图,并通过关键判别指标和临床获益独立验证。

主要发现

  • 人工诊断的假阳性率为30.6%。
  • 四种影像组学特征中,PET/CT影像组学特征表现最佳。
  • 混合列线图在训练集和测试集的假阳性率分别为5.4%和9.1%,AUC分别为0.98和0.92,Youden指数分别为85.8%和75.5%。
  • 混合列线图分别纠正了PET/CT影像组学特征所致假阳性病例的78.6%和37.5%,未显著牺牲敏感性。
  • 混合列线图在阈值概率<85%时净获益最高。

临床怎么用

  • 在肺癌疑似患者的18F-FDG PET/CT诊断中,可将PET/CT影像组学特征与人工诊断整合构建混合列线图以降低假阳性率。
  • 混合列线图在阈值概率<85%时净获益最高,可在此范围内用于临床决策支持。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: The high false positive rate (FPR) of 18F-FDG PET/CT in lung cancer screening represents a severe challenge for clinical decision-making. This study aimed to develop a clinical-translatable radiomics nomogram for reducing the FPR of PET/CT in lung cancer diagnosis, and to determine the impact of integrating manual diagnosis to the performance of the radiomics nomogram. METHODS: Among 3,947 18F-FDG PET/CT-screened patients with lung lesion, 157 malignant and 111 benign patients were retrospectively enrolled and divided into training and test cohorts. The data of manual diagnosis were recorded. A total of 4,338 features were extracted from CT, thin-section CT, PET and PET/CT, and the four radiomics signatures (RS) were then generated by LASSO method. Radiomics prediction nomogram integrating imaging-based RS and manual diagnosis was developed using multivariable logistic regression. The performances of RS and prediction nomograms were independently validated through key discrimination index and clinical benefit. RESULTS: The FPR of manual diagnosis was found to be 30.6%. Among the four RS, PET/CT RS exhibited the best performance. By integrating manual diagnosis, the hybrid nomogram integrating PET/CT RS and manual diagnosis demonstrated lowest FPR and highest area under curve (AUC) and Youden index (YI) in both training and test cohorts (FPR: 5.4% and 9.1%, AUC: 0.98 and 0.92, YI: 85.8% and 75.5%, respectively). This hybrid nomogram respectively corrected 78.6% and 37.5% among FPR cases produced by PET/CT RS, without significantly sacrificing its sensitivity. The net benefit of hybrid nomogram appeared highest at <85% threshold probability. CONCLUSION: The established hybrid nomogram integrating PET/CT RS and manual diagnosis can significantly reduce FPR, improve diagnostic accuracy and enhance clinical benefit compared to manual diagnosis. By integrating manual diagnosis, the performance of this hybrid nomogram is superior to PET/CT RS, indicating the importance of clinicians' judgement as an essential information source for improving radiomics diagnostic approaches.

来源:Eur J Nucl Med Mol Imaging,查看原文。版权归原作者所有。

引用

  1. Kang F, Mu W, Gong J, et al. Integrating manual diagnosis into radiomics for reducing the false positive rate of 18F-FDG PET/CT diagnosis in patients with suspected lung cancer. Eur J Nucl Med Mol Imaging. 2019. PMID: 31321483. doi:10.1007/s00259-019-04418-0

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。