11C-胆碱与11C-蛋氨酸PET/CT在多发性骨髓瘤中的比较
该回顾性研究纳入19例多发性骨髓瘤或孤立性骨浆细胞瘤患者,直接比较11C-胆碱与11C-蛋氨酸PET/CT的诊断效能。11C-蛋氨酸在8例(42.1%)中检出更多髓内MM病灶,且病灶-肌肉比值更高(P=0.0001);在12例有近期骨髓活检的患者中,两种示踪剂的SUVmean和SUVmax均与恶性浆细胞浸润程度显著相关。结论提示11C-蛋氨酸PET/CT可能比11C-胆碱更敏感。
要点
- 11C-蛋氨酸在42.1%患者中检出更多髓内MM病灶,其余患者两者结果相同。
- 11C-蛋氨酸的病灶-肌肉比值显著高于11C-胆碱(P=0.0001)。
- 两种示踪剂SUV均与骨髓浆细胞浸润程度显著相关。
核心结论
- 11C-蛋氨酸PET/CT可能比11C-胆碱PET/CT对检测活动性多发性骨髓瘤病灶更敏感。
研究设计与样本
- 回顾性分析纳入19例有多发性骨髓瘤病史(n=18)或孤立性骨浆细胞瘤(n=1)的患者,均接受11C-胆碱和11C-蛋氨酸PET/CT,按患者和病灶比较。
- 其中12例有近期骨髓活检,分析髂嵴示踪剂摄取与恶性骨髓浆细胞浸润程度的相关性。
主要发现
- 11C-蛋氨酸在8例(42.1%)中检出更多髓内MM病灶,其余11例(57.9%)两种示踪剂结果相同。
- 11C-蛋氨酸的病灶-肌肉比值更高(P=0.0001)。
- 12例有骨髓活检者中,11C-蛋氨酸SUVmean与浆细胞浸润程度相关(r=0.85,P<0.001),SUVmax相关(r=0.82,P=0.001)。
- 11C-胆碱SUVmean与浆细胞浸润程度相关(r=0.72,P<0.008),SUVmax相关(r=0.73,P=0.006)。
临床怎么用
- 在需要检测活动性MM病灶时,可考虑优先选用11C-蛋氨酸PET/CT,因其可能比11C-胆碱更敏感。
- 两种示踪剂的SUV与骨髓浆细胞浸润程度相关,可用于辅助评估骨髓受累程度。
局限性
- 回顾性分析,样本量仅19例,其中骨髓活检相关性分析仅12例。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: PET/CT with both C-choline and C-methionine has recently been reported to offer advantages over F-FDG for imaging in multiple myeloma (MM). The aim of this study was to directly compare the diagnostic performance of both non-FDG radiotracers in MM patients. METHODS: Nineteen patients with a history of MM (n = 18) or solitary bone plasmacytoma (n = 1) underwent both C-choline and C-methionine PET/CT for diagnostic imaging. In this retrospective analysis, scans were compared on a patient and on a lesion basis. In 12 patients, respective tracer uptake in the iliac crest was correlated with the extent of malignant bone marrow plasma cell infiltration. RESULTS: C-methionine detected more intramedullary MM lesions in 8 (42.1%) of 19 patients. In the remainder (11/19 [57.9%]), both C-choline and C-methionine provided equal results. C-methionine demonstrated higher lesion-to-muscle ratios (P = 0.0001). In the 12 patients in whom a recent bone marrow biopsy was available, SUVmean as well as SUVmax correlated significantly with the degree of malignant plasma cell infiltration for both C-methionine (SUVmean: r = 0.85, P < 0.001; SUVmax: r = 0.82, P = 0.001) and C-choline (SUVmean: r = 0.72, P < 0.008; SUVmax: r = 0.73; P = 0.006). CONCLUSIONS: Our data suggest that C-methionine PET/CT might be more sensitive than C-choline PET/CT for the detection of active MM lesions.
引用
- Lapa C, Kircher M, Da Via M, et al. Comparison of 11C-Choline and 11C-Methionine PET/CT in Multiple Myeloma. Clin Nucl Med. 2019. PMID: 31274607. doi:10.1097/RLU.0000000000002638
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。