文献速递骨显像与常规 SPECT肿瘤 PET/CT

18F-FDG PET/CT 诊断肩关节假体周围感染准确性不佳

18F FDG-PET/CT has poor diagnostic accuracy in diagnosing shoulder PJI.
PubMed 文献 · Eur J Nucl Med Mol Imaging · 2019-07-11

该前瞻性研究纳入86例评估肩关节置换失败的患者,术前均行18F-FDG PET/CT,由三名独立审阅者采用肩关节专用标准判读,以翻修手术标本细菌培养为金标准。结果显示灵敏度0.14、特异度0.91,阳性预测值0.40、阴性预测值0.71,作者认为18F-FDG PET/CT不能推荐用于常规术前评估低度肩关节假体周围感染。

要点

  • 18F-FDG PET/CT诊断肩关节低度假体周围感染灵敏度仅0.14。
  • 特异度0.91但阳性预测值仅0.40,阳性结果需谨慎解读。
  • 视觉判读的观察者间一致性为中等(Fleiss kappa 0.56)。

核心结论

  • 18F-FDG PET/CT对肩关节低度假体周围感染的诊断准确性不佳,不能推荐作为常规术前检查。

研究设计与样本

  • 前瞻性纳入3年内评估肩关节置换失败的患者,术前均行18F-FDG PET/CT。
  • 由三名独立审阅者采用肩关节专用标准判读感染征象,并计算观察者间一致性。
  • 以翻修手术标本细菌培养阳性作为感染金标准。

主要发现

  • 共纳入86例患者,18F-FDG PET/CT阳性9例,其中真阳性仅3例。
  • 金标准诊断翻修术后感染22例,均为慢性低毒力微生物所致。
  • 灵敏度0.14(95%CI 0.03-0.36),特异度0.91(95%CI 0.81-0.97)。
  • 阳性预测值0.40(95%CI 0.15-0.71),阴性预测值0.71(95%CI 0.67-0.75)。
  • 观察者间一致性Fleiss kappa为0.56,提示中等一致。

关键数值与推荐

  • 肩关节专用标准视觉判读的灵敏度0.14、特异度0.91、阳性预测值0.40、阴性预测值0.71。
  • 观察者间一致性Fleiss kappa 0.56。

临床怎么用

  • 不应将18F-FDG PET/CT作为肩关节置换术前常规诊断低度感染的检查。
  • 阳性结果需结合临床及其他检查谨慎解读,因阳性预测值仅0.40。

局限性

  • 原文未报告局限性内容。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: Chronic low-grade periprosthetic joint infection (PJI) of a shoulder replacement can be challenging to diagnose. 18F-FDG PET/CT is suggested as a modality to diagnose lower-limb PJI, but no studies on shoulder replacements exist. The aim of this study was therefore to determine the diagnostic accuracy of 18F-FDG PET/CT in diagnosing chronic PJI of the shoulder. METHODS: Patients evaluated for a failed shoulder replacement during a 3-year period were prospectively included in the study. All patients underwent pre-operative 18F-FDG PET/CT, and were evaluated for signs of infection by three independent reviewers using shoulder-specific criteria. Interrater-agreement was calculated between the reviewers. If the patient had revision surgery, biopsy specimens were obtained and cultured with bacterial growth in the cultures serving as gold standard of infection. RESULTS: A total of 86 patients were included in the study. Nine patients were 18F-FDG PET/CT positive for infection, with only three true positive. Using the gold standard, infection was diagnosed after revision surgery in 22 cases. All infections were chronic and caused by low-virulent microbes. The sensitivity of 18F-FDG PET/CT was 0.14 95% CI (0.03-0.36), specificity 0.91 95% CI (0.81-0.97), positive predictive value was 0.40 95% CI (0.15-0.71) and negative predictive value 0.71 95% CI (0.67-0.75). The inter-observer agreement was 0.56 (Fleiss' kappa), indicating moderate agreement of the visual FDG-PET evaluation using the shoulder-specific criteria. CONCLUSION: 18F-FDG PET/CT has poor diagnostic accuracy in diagnosing low-grade PJI of the shoulder. 18F-FDG PET/CT cannot be recommended as a part of the routine preoperative workup to diagnose low-grade infection of a shoulder replacement.

来源:Eur J Nucl Med Mol Imaging,查看原文。版权归原作者所有。

引用

  1. Falstie-Jensen T, Lange J, Daugaard H, et al. 18F FDG-PET/CT has poor diagnostic accuracy in diagnosing shoulder PJI. Eur J Nucl Med Mol Imaging. 2019. PMID: 31292698. doi:10.1007/s00259-019-04381-w

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。