PARaDIM:基于PHITS的四面体网格计算体模内照射剂量学蒙特卡洛工具
PARaDIM是一款免费软件,用于在四面体网格体模中通过蒙特卡洛模拟计算内照射吸收剂量,支持α、β、γ、正电子及俄歇/转换电子发射体。人体剂量计算与OLINDA 2.0在多数器官一致 within 10%-20%,细胞级S值与MIRDcell多数 within 5%。该工具通过图形界面降低使用门槛,促进先进计算体模在核医学剂量评估中的应用。
要点
- PARaDIM支持四面体网格体模的蒙特卡洛内照射剂量计算,涵盖多种医学相关核素。
- 人体剂量与OLINDA 2.0多数器官一致 within 10%-20%,细胞级S值与MIRDcell多数 within 5%。
- 提供图形界面,可计算区域平均剂量及三维剂量分布供影像软件分析。
核心结论
- PARaDIM将蒙特卡洛剂量计算拓展至更广泛核医学群体,利用先进计算体模提升放射药物剂量评估。
研究设计与样本
- 开发并验证PARaDIM软件,采用人体、小动物及细胞级剂量计算与广泛接受的剂量程序及文献数据比较。
主要发现
- 人体剂量计算中,PARaDIM与OLINDA 2.0在多数器官一致 within 10%-20%,尽管测试体模存在几何差异。
- 细胞级S值计算中,PARaDIM与MIRDcell在多数情况下一致 within 5%。
关键数值与推荐
- 人体剂量与OLINDA 2.0多数器官一致 within 10%-20%。
- 细胞级S值与MIRDcell多数情况下一致 within 5%。
临床怎么用
- 可用于核医学放射药物内照射剂量评估、研究及临床前开发,支持四面体网格体模的三维剂量分布分析。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
Mesh-type and voxel-based computational phantoms comprise the current state of the art for internal dose assessment via Monte Carlo simulations but excel in different aspects, with mesh-type phantoms offering advantages over their voxel counterparts in terms of their flexibility and realistic representation of detailed patient- or subject-specific anatomy. We have developed PARaDIM (pronounced "paradigm": Particle and Heavy Ion Transport Code System-Based Application for Radionuclide Dosimetry in Meshes), a freeware application for implementing tetrahedral mesh-type phantoms in absorbed dose calculations. It considers all medically relevant radionuclides, including α, β, γ, positron, and Auger/conversion electron emitters, and handles calculation of mean dose to individual regions, as well as 3-dimensional dose distributions for visualization and analysis in a variety of medical imaging software. This work describes the development of PARaDIM, documents the measures taken to test and validate its performance, and presents examples of its uses. Methods: Human, small-animal, and cell-level dose calculations were performed with PARaDIM and the results compared with those of widely accepted dosimetry programs and literature data. Several tetrahedral phantoms were developed or adapted using computer-aided modeling techniques for these comparisons. Results: For human dose calculations, agreement of PARaDIM with OLINDA 2.0 was good-within 10%-20% for most organs-despite geometric differences among the phantoms tested. Agreement with MIRDcell for cell-level S value calculations was within 5% in most cases. Conclusion: PARaDIM extends the use of Monte Carlo dose calculations to the broader community in nuclear medicine by providing a user-friendly graphical user interface for calculation setup and execution. PARaDIM leverages the enhanced anatomic realism provided by advanced computational reference phantoms or bespoke image-derived phantoms to enable improved assessments of radiation doses in a variety of radiopharmaceutical use cases, research, and preclinical development. PARaDIM can be downloaded freely at www.paradim-dose.org.
引用
- Carter LM, Crawford TM, Sato T, et al. PARaDIM: A PHITS-Based Monte Carlo Tool for Internal Dosimetry with Tetrahedral Mesh Computational Phantoms. J Nucl Med. 2019. PMID: 31201251. doi:10.2967/jnumed.119.229013
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。