文献速递心脏核医学

CZT 伽马相机定量心肌血流储备与冠状动脉造影病变的关系

Quantification of myocardial flow reserve using a gamma camera with solid-state cadmium-zinc-telluride detectors: Relation to angiographic coronary artery disease.
PubMed 文献 · J Nucl Cardiol · 2019-06-20

结果显示灌注异常者及高危冠心病(CAD)患者整体 MFR 降低,狭窄血管供血区区域 MFR 降低。结论认为 CZT 相机定量 MBF 与 MFR 可行,且能反映潜在病变。

要点

  • 灌注异常者整体 MFR 低于灌注正常者,负荷 MBF 亦降低。
  • 高危 CAD 患者整体 MFR 低于无梗阻性病变者。
  • 区域 MFR 2.2 识别相应动脉梗阻性病变的敏感度 63.2%、特异度 74.1%。

核心结论

  • 在接受有创冠状动脉造影评估 CAD 的患者中,CZT 伽马相机定量 MBF 与 MFR 可行,并能反映潜在病变,区域 MFR 降低提示存在梗阻性病变。

主要发现

  • 灌注异常患者整体 MFR 为 2.01(1.48-2.77),低于灌注正常者的 2.94(2.38-3.64),P=0.002,且负荷 MBF 降低。
  • 高危 CAD 患者整体 MFR 为 1.99(1.22-2.84),低于无梗阻性病变者的 2.89(2.22-3.58),P=0.026。
  • 梗阻血管区域 MFR 为 1.81(1.19-2.67),低于非梗阻血管的 2.75(2.13-3.42),P<0.001。

关键数值与推荐

  • 区域 MFR 取 2.2 时,识别相应动脉梗阻性病变的敏感度为 63.2%,特异度为 74.1%。

临床怎么用

  • 对转诊冠状动脉造影评估 CAD 的患者,可用 CZT 伽马相机在常规灌注显像基础上定量 MBF 与 MFR,区域 MFR 降低提示需关注相应动脉的梗阻性病变。

局限性

  • 原文摘要未报告研究局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Previous studies have suggested using gamma cameras with cadmium-zinc-telluride (CZT) detectors to quantify myocardial blood flow (MBF) and flow reserve (MFR). In this study, we aimed to evaluate the feasibility and accuracy of MFR quantification using a CZT camera compared to coronary angiography. METHODS: Forty-one participants referred for coronary angiography underwent a rest/stress one-day myocardial perfusion imaging protocol using a CZT gamma camera. Rest and stress dynamic phases were followed by acquisition of traditional perfusion images and time-activity curves were generated. Angiographic and perfusion results were compared to MFR. RESULTS: Patients with abnormal perfusion presented reduced MFR (2.01 [1.48-2.77] vs. 2.94 [2.38-3.64], P = 0.002), and reduced stress MBF. Patients with high-risk CAD had lower global MFR compared to patients without obstructive disease (1.99 [1.22-2.84] vs. 2.89 [2.22-3.58], P = 0.026). Obstructed vessels showed lower regional MFR when compared to non-obstructed (1.81 [1.19-2.67] vs. 2.75 [2.13-3.42], P < 0.001). A regional MFR of 2.2 provided a sensitivity of 63.2% and specificity of 74.1% to identify an obstructive lesion in the corresponding artery. CONCLUSION: In patients undergoing invasive coronary angiography for the evaluation of CAD, quantifying MBF and MFR in a CZT gamma camera is feasible and reflects underlying disease. In these patients, reduced regional MFR suggests the presence of obstructive lesion(s).

来源:J Nucl Cardiol,查看原文。版权归原作者所有。

引用

  1. de Souza ACDAH, Gonçalves BKD, Tedeschi AL, et al. Quantification of myocardial flow reserve using a gamma camera with solid-state cadmium-zinc-telluride detectors: Relation to angiographic coronary artery disease. J Nucl Cardiol. 2019. PMID: 31222529. doi:10.1007/s12350-019-01775-z

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。