文献速递心脏核医学

CZT相机SPECT的心肌灌注储备与最大缺血评分对比分析

Comparative analysis between myocardial perfusion reserve and maximal ischemia score at single photon emission computed tomography with new-generation cadmium-zinc-telluride cameras.
PubMed 文献 · J Nucl Cardiol · 2019-05-31

本研究纳入66例在新型镉锌碲(CZT)相机上行心肌灌注储备(MPR)检查的患者,比较MPR与最大缺血评分(MIS)的一致性及诊断价值。结果显示MPR与MIS、基线特征、区域灌注及血管造影显著冠心病(CAD)均无显著关联,而MIS与血管造影显著CAD相关(P < 0.05)。CZT衍生的MPR与基线风险、灌注和血管造影结果的一致性有限。

要点

  • MPR与MIS分组不一致:异常MPR而MIS正常者占24.2%,正常MPR而MIS异常者占18.1%。
  • 血管造影显著CAD仅与MIS相关(P < 0.05),与MPR无显著关联。
  • MPR与MIS、区域灌注及临床结局均无显著关联。

核心结论

  • CZT相机衍生的MPR与基线风险、灌注及血管造影结果之间一致性有限。
  • MPR能否为CAD诊断或预后带来增量获益尚不明确。

研究设计与样本

  • 回顾性查询机构数据库,纳入66例使用CZT相机行MPR检查的患者。
  • 主要目的是评估MPR在MIS之上或与之不一致时的增量诊断价值。

主要发现

  • 按MPR正常/异常(截断值2.1 mL/min/g)与MIS正常/异常分组:正常MPR且正常MIS 12例(18.1%),正常MPR且异常MIS 12例(18.1%),异常MPR且正常MIS 16例(24.2%),异常MPR且异常MIS 26例(39.4%)。
  • MIS与多项基线特征显著相关,而MPR无此关联。
  • MPR与MIS无显著关联,与区域灌注也无显著关联。
  • 临床结局少见且与MPR或MIS均无显著关联;血管造影显著CAD仅与MIS相关(P < 0.05),与MPR无关。

关键数值与推荐

  • MPR异常截断值为2.1 mL/min/g。
  • 血管造影显著CAD与MIS相关(P < 0.05),与MPR无显著关联。

临床怎么用

  • 在CZT相机SPECT中,MIS与血管造影显著CAD相关,可辅助CAD评估。
  • MPR与MIS及血管造影结果一致性有限,其增量诊断或预后价值尚待明确。

局限性

  • 样本量小(66例),临床结局少见。
  • MPR与MIS、灌注及血管造影结果一致性有限,结论需进一步验证。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Whether estimates of myocardial perfusion reserve (MPR) stemming from new-generation cadmium-zinc-telluride (CZT) cameras are accurate remains unclear. METHODS: We queried our institutional database for patients undergoing MPR with CZT cameras. The primary goal was appraising the incremental diagnostic yield of MPR on top or at odds of maximal ischemia score (MIS). RESULTS: A total of 66 subjects were included. When distinguishing patients according to normal vs abnormal MPR (cut-off 2.1 mL/min/g) and normal vs abnormal MIS, 4 groups could be identified: 12 (18.1%) individuals with normal MPR and MIS, 12 (18.1%) with normal MPR and abnormal MIS, 16 (24.2%) with abnormal MPR and normal MIS, and 26 (39.4%) with abnormal MPR and MIS. MIS was significantly associated with several baseline features, whereas MPR did not. There was no significant association between MPR and MIS, nor with regional perfusion. Clinical outcomes were uncommon and not significantly associated with MPR or MIS, whereas angiographically significant coronary artery disease (CAD) was associated solely with MIS (P < 0.05), and not with MPR. CONCLUSIONS: There is limited agreement between CZT-derived MPR and baseline risk, perfusion and angiography results. Whether such discrepancies may still prove incrementally beneficial for the diagnosis or prognosis of CAD remains unclear.

来源:J Nucl Cardiol,查看原文。版权归原作者所有。

引用

  1. Nudi F, Biondi-Zoccai G, Nudi A, et al. Comparative analysis between myocardial perfusion reserve and maximal ischemia score at single photon emission computed tomography with new-generation cadmium-zinc-telluride cameras. J Nucl Cardiol. 2019. PMID: 31152316. doi:10.1007/s12350-019-01764-2

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。