文献速递心脏核医学神经核医学

安德森-法布里病患者左心室123I-MIBG摄取局灶性减低与收缩功能受损的关系

Focal reduction in left ventricular 123I-metaiodobenzylguanidine uptake and impairment in systolic function in patients with Anderson-Fabry disease.
PubMed 文献 · J Nucl Cardiol · 2019-05-13

本研究纳入24例安德森-法布里病(AFD)患者,采用123I-MIBG心脏显像与斑点追踪超声心动图评估左心室区域交感神经去支配与区域功能异常的关系。结果显示,节段纵向应变随MIBG摄取评分增高而变差(P<0.001),全局纵向应变与总缺损评分(TDS)独立相关(B=3.007,95%CI 1.384–4.630,P=0.001)。结论认为心脏MIBG摄取减低反映AFD心脏受累严重程度,左心室纵向功能受损可能早于区域心肌去神经支配。

要点

  • 节段纵向应变随MIBG摄取评分升高而恶化(P<0.001)。
  • 节段纵向应变>-16.2%预测MIBG摄取评分≥1,敏感度79.7%、特异度65.3%。
  • 全局纵向应变与TDS独立相关(B=3.007,95%CI 1.384–4.630,P=0.001)。

核心结论

  • 心脏MIBG摄取减低反映AFD患者心脏受累的严重程度。
  • 左心室纵向功能受损可能是比区域心肌去神经支配更早的疾病特征。

研究设计与样本

  • 研究纳入24例AFD患者(年龄43.7±12.8岁),采用123I-MIBG心脏显像与斑点追踪超声心动图评估。
  • 节段示踪剂摄取按0–4分评分,并计算每位患者的总缺损评分(TDS)。

主要发现

  • 节段纵向应变随MIBG摄取评分增高而变差(P<0.001)。
  • ROC分析显示节段纵向应变>-16.2%预测节段MIBG摄取评分≥1,敏感度79.7%、特异度65.3%。
  • 24例AFD患者中13例存在节段性MIBG摄取缺损。
  • 有节段缺损者左室质量指数(60.8±10.1 vs 41.4±9.8 g/h2.7)、相对室壁厚度(0.51±0.06 vs 0.40±0.06)、收缩期肺动脉压(35.2±6.7 vs 27.2±4.2 mmHg)及纵向应变(-14.3±2.7 vs -19.4±1.8%)均显著更高(均P<0.01)。
  • 多变量线性回归显示全局纵向应变与TDS独立相关(B=3.007,95%CI 1.384–4.630,P=0.001)。

关键数值与推荐

  • 节段MIBG摄取评分采用0–4分法,TDS由各节段评分计算。
  • 节段纵向应变>-16.2%作为预测节段MIBG摄取评分≥1的临界值,敏感度79.7%、特异度65.3%。
  • 有节段缺损者左室质量指数、相对室壁厚度、收缩期肺动脉压及纵向应变均显著高于无缺损者(均P<0.01)。
  • 全局纵向应变与TDS独立相关(B=3.007,95%CI 1.384–4.630,P=0.001)。

临床怎么用

  • 在AFD患者中可结合123I-MIBG心脏显像与斑点追踪超声心动图评估心脏交感神经去支配与纵向功能受损。
  • 节段纵向应变>-16.2%提示可能存在节段性MIBG摄取缺损,需关注区域去神经支配。
  • 全局纵向应变与TDS独立相关,纵向功能指标可用于反映心脏受累严重程度。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Abnormalities of cardiac sympathetic innervation have been demonstrated in Anderson-Fabry disease (AFD). We aimed to investigate the relationship between regional left ventricular (LV) denervation and regional function abnormalities. METHODS: Twenty-four AFD patients (43.7 ± 12.8 years) were studied by 123I-metaiodobenzylguanidine (MIBG) cardiac imaging and speckle-tracking echocardiography. Segmental tracer uptake was estimated according to 0 to 4 score, and total defect score (TDS) was calculated for each patient. RESULTS: Segmental longitudinal strain worsened as MIBG uptake score increased (P < 0.001). By ROC analysis, a segmental longitudinal strain > - 16.2% predicted a segmental MIBG uptake score ≥1, with 79.7% sensitivity and 65.3% specificity. Segmental MIBG uptake defects were found in 13 out 24 AFD patients. LV mass index (60.8 ± 10.1 vs. 41.4 ± 9.8 g/h2.7), relative wall thickness (0.51 ± 0.06 vs. 0.40 ± 0.06), systolic pulmonary artery pressure (35.2 ± 6.7 vs. 27.2 ± 4.2 mmHg), and longitudinal strain (- 14.3 ± 2.7 vs. -19.4 ± 1.8%) were significantly higher in patients with segmental defect (all P < 0.01). At multivariate linear regression analysis, global longitudinal strain was independently associated with TDS (B = 3.007, 95% confidence interval 1.384 to 4.630, P = 0.001). CONCLUSIONS: Reduced cardiac MIBG uptake reflects the severity of cardiac involvement in AFD patients. LV longitudinal function impairment seems to be an earlier disease feature than regional myocardial denervation.

来源:J Nucl Cardiol,查看原文。版权归原作者所有。

引用

  1. Spinelli L, Imbriaco M, Giugliano G, et al. Focal reduction in left ventricular 123I-metaiodobenzylguanidine uptake and impairment in systolic function in patients with Anderson-Fabry disease. J Nucl Cardiol. 2019. PMID: 31087266. doi:10.1007/s12350-019-01734-8

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。