新一代CZT相机不同方案下短暂性缺血扩张比值的上限参考值:REFINE SPECT登记报告

Upper reference limits of transient ischemic dilation ratio for different protocols on new-generation cadmium zinc telluride cameras: A report from REFINE SPECT registry.
PubMed 文献 · J Nucl Cardiol · 2019-05-13

TID上限范围为1.18–1.52(97.5百分位)和1.18–1.39(均值+2SD),D-SPECT与Discovery相机间无差异(P=0.71),运动与血管扩张剂方案间有差异(均P<0.05)。

要点

  • CZT相机TID上限需按显像剂和负荷方案设定,范围1.18–1.52(97.5百分位)。
  • D-SPECT与Discovery相机TID参考上限无差异(P=0.71)。
  • 运动与血管扩张剂负荷方案间TID上限存在差异(均P<0.05)。

核心结论

  • 建立了CZT相机系统仰卧位下按相机、显像剂和方案特异的TID上限参考值。
  • D-SPECT与Discovery相机间TID参考上限无差异(P=0.71)。
  • 运动与血管扩张剂负荷方案间TID参考上限存在差异(均P<0.05)。

研究设计与样本

  • 图像用Cedars-Sinai定量灌注SPECT软件处理。
  • 推导仰卧位下非衰减校正、按相机、显像剂和负荷方案特异的TID上限,采用97.5百分位和均值+2SD。

主要发现

  • TID测量在8个亚组中6个不服从高斯分布。
  • TID上限范围为1.18–1.52(97.5百分位)和1.18–1.39(均值+2SD)。
  • D-SPECT与Discovery相机间无差异(P=0.71)。
  • 运动与血管扩张剂方案(腺苷、瑞加诺生或瑞加诺生-步行)间有差异(均P<0.05)。

关键数值与推荐

  • 仰卧位非衰减校正TID上限按97.5百分位为1.18–1.52,按均值+2SD为1.18–1.39。
  • 参考限值需按相机、显像剂和负荷方案特异设定。
  • D-SPECT与Discovery相机TID参考上限无差异(P=0.71)。
  • 运动与血管扩张剂负荷方案间TID参考上限有差异(均P<0.05)。

临床怎么用

  • 临床解读CZT相机TID时应使用匹配相机、显像剂和负荷方案的参考上限。
  • D-SPECT与Discovery相机可共用TID参考上限。
  • 运动与血管扩张剂负荷方案应采用不同的TID参考上限。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Upper reference limits for transient ischemic dilation (TID) have not been rigorously established for cadmium-zinc-telluride (CZT) camera systems. We aimed to derive TID limits for common myocardial perfusion imaging protocols utilizing a large, multicenter registry (REFINE SPECT). METHODS: One thousand six hundred and seventy-two patients with low likelihood of coronary artery disease with normal perfusion findings were identified. Images were processed with Quantitative Perfusion SPECT software (Cedars-Sinai Medical Center, Los Angeles, CA). Non-attenuation-corrected, camera-, radiotracer-, and stress protocol-specific TID limits in supine position were derived from 97.5th percentile and mean + 2 standard deviations (SD). Reference limits were compared for different solid-state cameras (D-SPECT vs. Discovery), radiotracers (technetium-99m-sestamibi vs. tetrofosmin), different types of stress (exercise vs. four different vasodilator-based protocols), and different vasodilator-based protocols. RESULTS: TID measurements did not follow Gaussian distribution in six out of eight subgroups. TID limits ranged from 1.18 to 1.52 (97.5th percentile) and 1.18 to 1.39 (mean + 2SD). No difference was noted between D-SPECT and Discovery cameras (P = 0.71) while differences between exercise and vasodilator-based protocols (adenosine, regadenoson, or regadenoson-walk) were noted (all P < 0.05). CONCLUSIONS: We used a multicenter registry to establish camera-, radiotracer-, and protocol-specific upper reference limits of TID for supine position on CZT camera systems. Reference limits did not differ between D-SPECT and Discovery camera.