小鼠门控核素心肌灌注显像心脏功能参数测量的准确性
该研究在健康C57Bl/6N小鼠(n=11)和心肌梗死后1周小鼠(n=13)中,比较了99mTc-sestamibi SPECT与13N-ammonia PET门控核素灌注显像所测左心室功能参数与解剖影像(CMR、对比增强CT)的一致性。健康小鼠中核素影像低估左心室容积(23%至28%,P=0.02),但LVEF相当(SPECT 73±8% vs CMR 72±6%,P=0.1);梗死后核素影像LV容积显著低于CMR和CT(P=0.003),LVEF被轻度高估(SPECT 37±8% vs CMR 27±7%,P=0.003)。灌注SPECT所测梗死面积与组织学高度相关(r=0.95,P<0.001)。
要点
- 健康小鼠中门控核素灌注显像可计算心脏功能,LVEF与CMR相当但左心室容积被低估。
- 心肌梗死后核素灌注显像高估LVEF,与其他模态比较时需考虑此差异。
- 灌注SPECT可准确计算梗死面积,与组织学相关性好(r=0.95)。
核心结论
- 健康小鼠中门控核素灌注显像可测量心脏收缩功能,但梗死后LVEF会被高估。
- 灌注SPECT计算的梗死面积与组织学高度一致。
研究设计与样本
- 健康C57Bl/6N小鼠(n=11)行99mTc-sestamibi SPECT和13N-ammonia PET门控心肌灌注显像,并与解剖影像比较。
- 心肌梗死后1周小鼠(n=13)行灌注显像,并与CMR和对比增强CT比较。
主要发现
- 健康小鼠中核素影像低估左心室容积23%至28%(P=0.02),LVEF与CMR相当(SPECT 73±8% vs CMR 72±6%,P=0.1)。
- 梗死后1周核素影像左心室容积显著低于CMR和CT(P=0.003),LVEF被轻度高估(SPECT 37±8% vs CMR 27±7%,P=0.003)。
- 核素影像的组内和组间读片一致性良好。
- 灌注SPECT所测梗死面积与组织学高度相关(r=0.95,P<0.001)。
临床怎么用
- 小鼠纵向研究中可结合门控核素灌注显像同时评估心脏功能和梗死面积。
- 梗死后LVEF解读需注意核素灌注显像的高估倾向。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Quantitative cardiac contractile function assessment is the primary indicator of disease progression and therapeutic efficacy in small animals. Operator dependency is a major challenge with commonly used echocardiography. Simultaneous assessment of cardiac perfusion and function in nuclear scans would reduce burden on the animal and facilitate longitudinal studies. We evaluated the accuracy of contractile function measurements obtained from electrocardiogram-gated nuclear perfusion imaging compared with anatomic imaging. METHODS AND RESULTS: In healthy C57Bl/6N mice (n = 11), 99mTc-sestamibi SPECT and 13N-ammonia PET underestimated left ventricular volumes (23 to 28%, P = 0.02) compared to matched anatomic images, though ejection fraction (LVEF) was comparable (%, SPECT: 73 ± 8 vs CMR: 72 ± 6, P = 0.1). At 1 week after myocardial infarction (n = 13), LV volumes were significantly lower in perfusion images compared to CMR and contrast CT (P = 0.003), and LVEF was modestly overestimated (%, SPECT: 37 ± 8, vs CMR: 27 ± 7, P = 0.003). Nuclear images exhibited good intra- and inter-reader agreement. Perfusion SPECT accurately calculated infarct size compared to histology (r = 0.95, P < 0.001). CONCLUSIONS: Cardiac function can be calculated by gated nuclear perfusion imaging in healthy mice. After infarction, perfusion imaging overestimates LVEF, which should be considered for comparison to other modalities. Combined functional and infarct size analysis may optimize imaging protocols and reduce anaesthesia duration for longitudinal studies.
引用
- Hess A, Nekolla SG, Meier M, et al. Accuracy of cardiac functional parameters measured from gated radionuclide myocardial perfusion imaging in mice. J Nucl Cardiol. 2019. PMID: 31044402. doi:10.1007/s12350-019-01713-z