静态与动态18F-FDG PET/CT定量急性肺损伤肺部炎症的比较
该研究在14只麻醉猪的ARDS模型中,比较静态18F-FDG PET/CT的SUV和SURstat与动态PET/CT Patlak分析Ki对肺部炎症的定量。结果显示Ki与SURstat线性相关更强(r2≥0.84),SURstat和SUV分别有98.6%和84.3%的测量与Ki变化方向一致。提示静态SURstat分析可作为动态Patlak分析的替代。
要点
- 在实验性ARDS猪模型中,Ki与SURstat的线性相关优于Ki与SUV。
- SURstat在98.6%的测量中与Ki追踪相同的区域炎症变化方向。
- 静态SURstat分析可评估全肺、支持重复测量并加快数据采集。
核心结论
- Ki与SURstat的相关性明显强于Ki与SUV的相关性,静态SURstat分析可替代动态Patlak分析定量肺部炎症。
研究设计与样本
- 在14只麻醉猪(29.5-40.0 kg)中经盐水肺灌洗联合损伤性机械通气诱导ARDS,于机械通气前和24小时后采集动态及静态18F-FDG PET/CT。
主要发现
- 对整个成像视野和腹背方向5个肺区,Ki与SURstat均呈线性相关(r2≥0.84),而Ki与SUV相关性较差(r2≤0.75)。
- 动脉输入函数在所有动物和时间点形状基本不变,可用反幂律描述。
- 与Ki相比,SURstat和SUV分别在98.6%和84.3%的测量中追踪相同的区域肺部炎症变化方向。
关键数值与推荐
- Ki由动态18F-FDG PET/CT的Patlak分析计算,表观分布容积亦由Patlak分析得出。
- SURstat为 uptake time 校正的肺组织与血浆18F-FDG浓度比值。
临床怎么用
- 静态18F-FDG PET/CT结合SURstat分析可用于实验性ARDS肺部炎症定量,支持全肺评估、18F-FDG衰变期内重复测量和更快数据采集。
局限性
- 研究为实验性ARDS猪模型,样本量为14只动物。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PET imaging with 18F-FDG followed by mathematic modeling of the pulmonary uptake rate (Ki) is the gold standard for assessment of pulmonary inflammation in experimental studies of acute respiratory distress syndrome (ARDS). However, dynamic PET requires long imaging and allows the assessment of only 1 cranio-caudal field of view (∼15 cm). We investigated whether static 18F-FDG PET/CT and analysis of SUV or standardized uptake ratios (SURstat, uptake time-corrected ratio of 18F-FDG concentration in lung tissue and blood plasma) might be an alternative to dynamic 18F-FDG PET/CT and Patlak analysis for quantification of pulmonary inflammation in experimental ARDS. Methods: ARDS was induced by saline lung lavage followed by injurious mechanical ventilation in 14 anesthetized pigs (29.5-40.0 kg). PET/CT imaging sequences were acquired before and after 24 h of mechanical ventilation. Ki and the apparent volume of distribution were calculated from dynamic 18F-FDG PET/CT scans using the Patlak analysis. Static 18F-FDG PET/CT scans were obtained immediately after dynamic PET/CT and used for calculations of SUV and SURstat Mean Ki values of the whole imaged field of view and of 5 ventro-dorsal lung regions were compared with corresponding SUV and SURstat values, respectively, by means of linear regression and concordance analysis. The variability of the 18F-FDG concentration in blood plasma (arterial input function) was analyzed. Results: Both for the whole imaged field of view and ventro-dorsal subregions, Ki was linearly correlated with SURstat (r2 ≥ 0.84), whereas Ki-SUV correlations were worse (r2 ≤ 0.75). The arterial input function exhibited an essentially invariant shape across all animals and time points and can be described by an inverse power law. Compared with Ki, SURstat and SUV tracked the same direction of change in regional lung inflammation in 98.6% and 84.3% of measurements, respectively. Conclusion: The Ki-SURstat correlations were considerably stronger than the Ki-SUV correlations. The good Ki-SURstat correlations suggest that static 18F-FDG PET/CT and SURstat analysis provides an alternative to dynamic 18F-FDG PET/CT and Patlak analysis, allowing the assessment of inflammation of whole lungs, repeated measurements within the period of 18F-FDG decay, and faster data acquisition.
引用
- Braune A, Hofheinz F, Bluth T, et al. Comparison of Static and Dynamic 18F-FDG PET/CT for Quantification of Pulmonary Inflammation in Acute Lung Injury. J Nucl Med. 2019. PMID: 31053684. doi:10.2967/jnumed.119.226597
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。