文献速递心脏核医学

心肌梗死患者左心室容积与射血分数:99mTc-MIBI门控SPECT与18F-FDG门控PET评估

Evaluation of left ventricular volumes and ejection fraction by 99mTc-MIBI gated SPECT and 18F-FDG gated PET in patients with prior myocardial infarction.
PubMed 文献 · J Nucl Cardiol · 2019-04-16

结果显示GSPECT和GPET与CMR的相关性均良好,但个体患者中两者不可互换。

要点

  • GSPECT与GPET测量的LV EDV、ESV和LVEF与CMR相关性良好(r=0.618~0.949)。
  • 在不同总灌注缺损程度、存活心肌及灌注/代谢匹配状态下,GPET测量均准确。
  • 匹配分数与GPET和CMR间EDV测量差异相关(P<0.05)。

核心结论

  • 在心肌梗死患者中,GSPECT和GPET测量的左心室容积和LVEF与CMR相当,但个体患者中不可互换。

研究设计与样本

  • 使用QGS、ECTB和4DM三种软件测量左心室容积和LVEF。

主要发现

  • GPET、GSPECT与CMR的LV EDV相关性r=0.855~0.914,ESV相关性r=0.852~0.949,LVEF相关性r=0.618~0.820(基于QGS、ECTB和4DM计算)。
  • 亚组分析显示,在不同总灌注缺损程度、存活心肌及灌注/代谢匹配状态下,GPET测量的EDV、ESV和LVEF均准确。
  • 多因素回归分析显示,匹配分数与GPET和CMR间EDV测量差异相关(P<0.05)。

临床怎么用

  • 临床可选择GSPECT或GPET评估心肌梗死患者的左心室容积和LVEF,但同一患者随访中不宜互换方法。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: This study aimed to compare the accuracy of gated-SPECT (GSPECT) and gated-PET (GPET) in the assessment of left ventricular (LV) end-diastolic volumes (EDVs), end-systolic volumes (ESVs) and LV ejection fractions (LVEFs) among patients with prior myocardial infarction (MI). METHODS: One hundred and sixty-eight consecutive patients with MI who underwent GSPECT and GPET were included. Of them, 76 patients underwent CMR in addition to the two imaging modalities. The measurements of LV volumes and LVEF were performed using Quantitative Gated SPECT (QGS), Emory Cardiac Toolbox (ECTB), and 4D-MSPECT (4DM). RESULTS: The correlation between GPET, GSPECT, and CMR were excellent for LV EDV (r = 0.855 to 0.914), ESV (r = 0.852 to 0.949), and LVEF (r = 0.618 to 0.820), as calculated from QGS, ECTB, and 4DM. In addition, subgroup analysis revealed that EDV, ESV, and LVEF measured by GPET were accurate in patients with different extents of total perfusion defect (TPD), viable myocardium, and perfusion/metabolic mismatch. Furthermore, multivariate regression analysis identified that mismatch score was associated with the difference in EDV (P < 0.05) measurements between GPET and CMR. CONCLUSIONS: In patients with MI, LV volumes and LVEF scores measured by both GSPECT and GPET imaging were comparable to those determined by CMR, but should not be interchangeable in individual patients.

来源:J Nucl Cardiol,查看原文。版权归原作者所有。

引用

  1. Yao Y, Wang DW, Fang W, et al. Evaluation of left ventricular volumes and ejection fraction by 99mTc-MIBI gated SPECT and 18F-FDG gated PET in patients with prior myocardial infarction. J Nucl Cardiol. 2019. PMID: 30993654. doi:10.1007/s12350-019-01709-9

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。