瑞加诺生负荷PET在左束支传导阻滞患者中的初步经验:间隔缺损低发生率及对阻塞性冠脉疾病的高准确性
研究纳入101例基线左束支传导阻滞(LBBB)且无已知冠脉疾病(CAD)的患者,行静息-负荷瑞加诺生PET。输注瑞加诺生后心率中位数从78升至93次/分,但未发现LBBB相关灌注伪影。10例患者1年内同时接受SPECT和PET,3例SPECT有LBBB伪影而后续PET均未见。21例PET后行冠脉造影,9例PET无显著诱发性缺血且造影无限流病变,3例PET有诱发性缺血但造影无限流病变,9例PET有诱发性缺血且造影有限流病变。结论:LBBB患者行瑞加诺生PET负荷显像时,伪感性间隔灌注缺损罕见。
要点
- LBBB患者行瑞加诺生PET负荷显像时,间隔灌注伪影罕见。
- 瑞加诺生输注后心率中位数从78升至93次/分,未出现LBBB灌注伪影。
- PET对阻塞性CAD的评估与冠脉造影结果高度一致。
核心结论
- 在左束支传导阻滞患者中,瑞加诺生PET负荷显像的伪感性间隔灌注缺损罕见。
研究设计与样本
- 连续纳入101例基线LBBB且无已知CAD的患者,行静息-负荷瑞加诺生PET检查。
- 研究者可前瞻性识别因LBBB伪影而质量受限的检查。
- 10例患者1年内同时接受瑞加诺生SPECT和PET,21例PET后行冠脉造影。
主要发现
- 输注瑞加诺生后,静息至峰值心率中位数从78升至93次/分。
- 所有研究均未识别出LBBB灌注伪影。
- 10例同时行SPECT和PET的患者中,3例SPECT有LBBB伪影,后续PET均未见。
- 21例行冠脉造影患者中,9例PET无显著诱发性缺血且造影无限流病变,3例PET有诱发性缺血但造影无限流病变,9例PET有诱发性缺血且造影有限流病变。
临床怎么用
- 对于LBBB患者,瑞加诺生PET负荷显像可用于评估阻塞性CAD,伪影干扰少。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Assessing for coronary artery disease (CAD) in patients with left bundle branch block (LBBB) is difficult with noninvasive cardiac imaging. Few studies report the prevalence of LBBB associated septal-apical perfusion defects using regadenoson stress on Positron Electron Tomography (PET) imaging. METHODS AND RESULTS: We identified 101 consecutive patients with baseline LBBB, and without known CAD, who underwent rest-stress regadenoson PET. Investigators have the ability to prospectively identify studies, whose quality is limited by LBBB artifact. With the infusion of regadenoson, resting to peak stress heart rate rose from a median of 78 to 93 BPM. Despite this, LBBB perfusion artifacts were not identified in any studies. 10 individuals had both regadenoson SPECT and PET within 1 year. 3 of the 10 SPECT studies had LBBB artifacts, all of which were not seen on subsequent PET. 21 patients with PET had subsequent coronary angiography. Of these, 9 PETs were without significant inducible ischemia, and angiogram was without flow-limiting disease. 3 PETs identified inducible ischemia, but did not have flow-limiting disease on angiogram. 9 PETs identified inducible ischemia and had flow-limiting disease on angiogram. CONCLUSIONS: In patients with LBBB undergoing regadenoson PET stress imaging, artifactual septal perfusion defects are rare.
引用
- Meredith D, Cremer PC, Harb SC, et al. Initial experience with regadenoson stress positron emission tomography in patients with left bundle branch block: Low prevalence of septal defects and high accuracy for obstructive coronary artery disease. J Nucl Cardiol. 2019. PMID: 30877551. doi:10.1007/s12350-019-01681-4
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。