缺血性心脏病中血流与储备量化的软件可重复性:13N-氨PET研究
本研究对比QPET、SyngoMBF和Carimas三种软件在91例患者中量化静息MBF、负荷MBF和MFR的一致性。正常灌注患者中部分负荷MBF比较超出一致性界限,可逆性缺损患者所有负荷MBF和MFR比较均超出界限,固定缺损患者所有比较均在界限内。
要点
- 可逆性缺损患者的负荷MBF和MFR软件间一致性最差。
- 软件间一致性差异具有区域依赖性,主要见于LAD供血区。
- 不应假设不同软件包之间的可重复性。
核心结论
- 可逆性缺损患者中全局负荷MBF和MFR的软件间一致性最差,且差异呈区域依赖性。
- 不应假设不同软件包之间的可重复性。
研究设计与样本
- 研究纳入91例患者的扫描,按半定量灌注结果分为正常灌注、可逆性缺损和固定缺损三个亚组。
- 使用QPET、SyngoMBF和Carimas三种软件获取静息MBF、负荷MBF和MFR。
- 软件间一致性判定标准为配对标准化差异<0.20且组内相关系数≥0.75。
主要发现
- 正常灌注患者中,全局负荷MBF量化的三次比较中有两次超出一致性界限。
- 缺血患者中,全局负荷MBF和MFR的所有比较均超出既定一致性界限。
- 固定缺损患者中,所有软件比较的灌注量化均在一致性界限内。
- 区域层面的一致性主要见于左前降支血管 territory。
关键数值与推荐
- 一致性可接受定义为配对标准化差异<0.20且组内相关系数≥0.75。
临床怎么用
- 临床解读负荷MBF和MFR时应考虑软件包差异,尤其可逆性缺损患者。
- 区域分析时需注意软件间一致性可能因血管 territory 而异。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: We explored agreement in the quantification of myocardial perfusion by cross-comparison of implemented software packages (SPs) in three distinguishable patient profile populations. METHODS: We studied 91 scans of patients divided into 3 subgroups based on their semi-quantitative perfusion findings: patients with normal perfusion, with reversible perfusion defects, and with fixed perfusion defects. Rest myocardial blood flow (MBF), stress MBF, and myocardial flow reserve (MFR) were obtained with QPET, SyngoMBF, and Carimas. Agreement between SPs was considered adequate when a pairwise standardized difference was found to be < 0.20 and its corresponding intraclass correlation coefficient was ≥ 0.75. RESULTS: In patients with normal perfusion, two out of three comparisons of global stress MBF quantifications were outside the limits of agreement. In ischemic patients, all comparisons of global stress MBF and MFR were outside the limits of established agreement. In patients with fixed perfusion defects, all SP comparisons of perfusion quantifications were within the limit of agreement. Regionally, agreement of these perfusion estimates was mostly found for the left anterior descending artery vascular territory. CONCLUSION: Reversible defects demonstrated the worst agreement in global stress MBF and MFR and discrepancies showed to be regional dependent. Reproducibility between SPs should not be assumed.
引用
- Monroy-Gonzalez AG, Juarez-Orozco LE, Han C, et al. Software reproducibility of myocardial blood flow and flow reserve quantification in ischemic heart disease: A 13N-ammonia PET study. J Nucl Cardiol. 2019. PMID: 30903608. doi:10.1007/s12350-019-01620-3
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。