动态CZT显像获得的绝对心肌血流量与有创FFR的相关性及准确性

Absolute myocardial blood flows derived by dynamic CZT scan vs invasive fractional flow reserve: Correlation and accuracy.
PubMed 文献 · J Nucl Cardiol · 2019-03-07

结果显示负荷MBF、CFR和FD与FFR异常有较好预测价值,提示动态CZT显像可能有助于识别血流动力学显著的冠心病。

要点

  • 负荷MBF≤0.54 mL/min/g预测FFR异常的敏感性61.5%、特异性93.3%。
  • CFR≤1.48预测FFR异常的敏感性69.2%、特异性93.3%。
  • FD≤0.18 mL/min/g预测FFR异常的敏感性69.2%、特异性100%。

核心结论

  • 动态CZT显像获得的负荷MBF、CFR和FD与有创FFR比较具有较好的一致性,可能有助于识别血流动力学显著的冠心病。

研究设计与样本

  • 采用Leppo净滞留模型半自动计算负荷与静息MBF,并估算CFR和FD。
  • 对28支血管行FFR功能定量,其中19支(68%)狭窄≥70%,9支(32%)狭窄<70%。

主要发现

  • 全局静息MBF均值为0.36(IQR 0.33-0.54)mL/min/g,负荷MBF均值为0.67(IQR 0.55-0.81)mL/min/g,平均CFR为1.80(IQR 1.35-2.24)。
  • 狭窄严重程度与FFR(r=0.45;P=.01)、负荷MBF(r=-0.46;P=.01)和FD(r=-0.37;P=.04)呈中度相关。
  • FFR异常的最佳预测指标为绝对负荷MBF≤0.54 mL/min/g(敏感性61.5%;特异性93.3%)、CFR≤1.48(敏感性69.2%;特异性93.3%)和FD≤0.18 mL/min/g(敏感性69.2%;特异性100%)。

关键数值与推荐

  • 负荷MBF≤0.54 mL/min/g预测FFR异常的敏感性61.5%、特异性93.3%。
  • CFR≤1.48预测FFR异常的敏感性69.2%、特异性93.3%。
  • FD≤0.18 mL/min/g预测FFR异常的敏感性69.2%、特异性100%。

临床怎么用

  • 动态CZT显像获得的负荷MBF、CFR和FD可作为无创评估冠心病血流动力学意义的参考指标。
  • 临床可结合负荷MBF、CFR和FD辅助识别可能需要血运重建的血流动力学显著狭窄。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To define the diagnostic power of absolute myocardial blood flow (MBF) evaluation on dynamic CZT imaging in intermediate risk patients in comparison with invasive coronary angiography (ICA) and fractional flow reserve (FFR). METHODS: Twenty-three stable CAD patients underwent one-day dynamic rest-stress 99mTc-Sestamibi myocardial perfusion imaging by CZT camera. Stress and rest MBF values were calculated semi-automatically using a net retention model by Leppo. Coronary flow reserve (CFR) and flow difference (FD) [MBF stress - MBF rest] were also estimated. A total of 28 vessels were functionally quantified with FFR: 19 (68%) vessels with a stenosis ≥ 70% and 9 (32%) with < 70% stenotic lesions. RESULTS: The mean global MBFs at rest and during stress were 0.36 (IQR 0.33-0.54) mL/min/g and 0.67 (IQR 0.55-0.81) mL/min/g, respectively, with an average CFR of 1.80 (IQR 1.35-2.24). Moderate correlations between stenosis severity and FFR (r = 0.45; P = .01), stress MBF (r = -0.46; P = .01) and FD (r = -0.37; P = .04) were detected. FFR abnormalities were best predicted by absolute stress MBF, CFR and FD with values of ≤ 0.54 mL/min/g (sensitivity 61.5%; specificity 93.3%), ≤ 1.48 (sensitivity 69.2%; specificity 93.3%) and ≤ 0.18 mL/min/g (sensitivity 69.2%; specificity 100%), respectively. CONCLUSIONS: The values of stress MBF, CFR and FD obtained through dynamic CZT acquisitions compare well with invasive FFR. The clinical use of dynamic acquisition of myocardial perfusion imaging by CZT may help cardiologist in the detection of hemodynamically significant CAD.

来源:J Nucl Cardiol,查看原文。版权归原作者所有。