优化呼吸门控[18F]FDG PET/CT对胰腺导管腺癌代谢参数定量及其与总生存相关性的显著影响
从标准与ORG图像计算标准参数、一阶和二阶纹理特征,并评估其与总生存(OS)的相关性。结果显示ORG显著影响几乎所有特征的定量,单体素参数(如SUVmax)范围更宽、基于体积的参数(如SUVmean)降低、纹理特征显著改变;校正呼吸运动伪影后,部分描述瘤内异质性的特征与OS相关性更强。
要点
- ORG显著影响胰腺导管腺癌几乎所有PET代谢特征的定量。
- ORG使单体素参数范围更宽、体积参数降低、纹理特征显著改变。
- 校正呼吸运动伪影后,部分瘤内异质性特征与OS相关性更强。
核心结论
- 使用ORG校正呼吸运动伪影会影响胰腺导管腺癌病灶代谢参数的定量。
- 代谢参数与OS的相关性受到显著影响,尤其是描述瘤内异质性的参数。
- 解释单体素或平均代谢参数与临床结局的关系时应谨慎。
- ORG是改善胰腺导管腺癌瘤内异质性定量的有价值工具。
研究设计与样本
- 标准图像采集与重建依照EANM指南进行,ORG图像以35%占空比重建。
- 从标准与对应ORG图像计算标准参数、一阶和二阶纹理特征,并评估其与OS的相关性。
主要发现
- ORG显著影响几乎所有特征的定量。
- 单体素参数(如SUVmax)值显示更宽的范围,基于体积的参数(如SUVmean)降低。
- 纹理特征显著改变。
- 使用ORG校正运动伪影后,部分描述瘤内异质性的特征与OS相关性更强。
临床怎么用
- 解读胰腺导管腺癌单体素或平均代谢参数与临床结局的关系时应谨慎。
- ORG可用于改善胰腺导管腺癌瘤内异质性的定量。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: Metabolic parameters are increasingly being used to characterize tumors. Motion artifacts due to patient respiration introduce uncertainties in quantification of metabolic parameters during positron emission tomography (PET) image acquisition. The present study investigates the impact of amplitude-based optimal respiratory gating (ORG) on quantification of PET-derived image features in patients with pancreatic ductal adenocarcinoma (PDAC), in correlation with overall survival (OS). METHODS: Sixty-nine patients with histologically proven primary PDAC underwent 2'-deoxy-2'-[18F]fluoroglucose ([18F]FDG) PET/CT imaging during diagnostic work-up. Standard image acquisition and reconstruction was performed in accordance with the EANM guidelines and ORG images were reconstructed with a duty cycle of 35%. PET-derived image features, including standard parameters, first- and second-order texture features, were calculated from the standard and corresponding ORG images, and correlation with OS was assessed. RESULTS: ORG significantly impacts the quantification of nearly all features; values of single-voxel parameters (e.g., SUVmax) showed a wider range, volume-based parameters (e.g., SUVmean) were reduced, and texture features were significantly changed. After correction for motion artifacts using ORG, some features that describe intra-tumoral heterogeneity were more strongly correlated to OS. CONCLUSIONS: Correction for respiratory motion artifacts using ORG impacts the quantification of metabolic parameters in PDAC lesions. The correlation of metabolic parameters with OS was significantly affected, in particular parameters that describe intra-tumor heterogeneity. Therefore, interpretation of single-voxel or average metabolic parameters in relation to clinical outcome should be done cautiously. Furthermore, ORG is a valuable tool to improve quantification of intra-tumoral heterogeneity in PDAC.
引用
- Smeets EMM, Withaar DS, Grootjans W, et al. Optimal respiratory-gated [18F]FDG PET/CT significantly impacts the quantification of metabolic parameters and their correlation with overall survival in patients with pancreatic ductal adenocarcinoma. EJNMMI Res. 2019. PMID: 30868318. doi:10.1186/s13550-019-0492-y
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。