68Ga-DOTA-PET定量评估心肌血流量与细胞外容积分数的可行性及验证:大型动物研究
该研究在猪心肌梗死模型中评估68Ga-DOTA-PET无创定量心肌血流量(MBF)和细胞外容积分数(ECV)的可行性,并以微球法作为金标准验证MBF测量。8头健康猪接受静息和药物负荷下三次68Ga-DOTA-PET/CT扫描并同步注射荧光微球;另5头猪在再灌注后7天行68Ga-DOTA-PET/CT检查。结果显示68Ga-DOTA-PET测得的MBF与微球法相关性良好(r=0.91),梗死区MBF较远端区域显著降低,ECV在梗死区显著升高。
要点
- 68Ga-DOTA-PET测得的MBF与微球法金标准相关性良好(r=0.91)。
- 梗死区(LAD供血区)MBF较LCX和RCA供血区显著降低(均P<0.0001)。
- 梗死区ECV显著升高(P<0.0001),提示该技术可无创评估MBF和ECV。
核心结论
- 68Ga-DOTA-PET可在静息-负荷条件下无创评估猪心肌梗死模型的MBF和ECV,该技术有望广泛用于PET定量测量MBF和ECV。
研究设计与样本
- 研究纳入8头健康猪,在静息和药物负荷下行三次连续68Ga-DOTA-PET/CT扫描,同步注射荧光微球以验证MBF测量。
- 另在5头猪中诱导心肌梗死,于再灌注后7天行68Ga-DOTA-PET/CT检查。
- 动态PET图像经重建和拟合获得MBF与ECV参数图。
主要发现
- 68Ga-DOTA-PET测得的MBF与微球法测量值相关性良好(y=0.96x+0.11,r=0.91)。
- 梗死区(LAD供血区)MBF较远端LCX供血区(P<0.0001)和RCA供血区(P<0.0001)显著降低。
- 梗死区ECV显著升高(P<0.0001)。
临床怎么用
- 68Ga-DOTA-PET可用于无创定量评估MBF和ECV,有望为心肌梗死患者提供血流与间质纤维化的同步定量信息。
局限性
- 研究为猪动物模型,样本量较小(健康猪8头、心肌梗死猪5头),尚未在人体中验证。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Here we evaluated the feasibility of PET with Gallium-68 (68Ga)-labeled DOTA for non-invasive assessment of myocardial blood flow (MBF) and extracellular volume fraction (ECV) in a pig model of myocardial infarction. We also aimed to validate MBF measurements using microspheres as a gold standard in healthy pigs. METHODS: 8 healthy pigs underwent three sequential 68Ga-DOTA-PET/CT scans at rest and during pharmacological stress with simultaneous injection of fluorescent microspheres to validate MBF measurements. Myocardial infarction was induced in 5 additional pigs, which underwent 68Ga-DOTA-PET/CT examinations 7-days after reperfusion. Dynamic PET images were reconstructed and fitted to obtain MBF and ECV parametric maps. RESULTS: MBF assessed with 68Ga-DOTA-PET showed good correlation (y = 0.96x + 0.11, r = 0.91) with that measured with microspheres. MBF values obtained with 68Ga-DOTA-PET in the infarcted area (LAD, left anterior descendant) were significantly reduced in comparison to remote ones LCX (left circumflex artery, P < 0.0001) and RCA (right coronary artery, P < 0.0001). ECV increased in the infarcted area (P < 0.0001). CONCLUSION: 68Ga-DOTA-PET allowed non-invasive assessment of MBF and ECV in pigs with myocardial infarction and under rest-stress conditions. This technique could provide wide access to quantitative measurement of both MBF and ECV with PET imaging.
引用
- Velasco C, Mota-Cobián A, Mota RA, et al. Quantitative assessment of myocardial blood flow and extracellular volume fraction using 68Ga-DOTA-PET: A feasibility and validation study in large animals. J Nucl Cardiol. 2019. PMID: 30927149. doi:10.1007/s12350-019-01694-z
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。