文献速递心脏核医学

定量心肌血流量与13N-氨水洗脱在缺血性心肌病存活心肌评估中的作用

Role of quantitative myocardial blood flow and 13N-ammonia washout for viability assessment in ischemic cardiomyopathy.
PubMed 文献 · J Nucl Cardiol · 2019-03-20

本研究在180例缺血性心肌病患者中,以18F-FDG PET为参考标准,评估动态13N-氨水PET衍生的应力MBF、静息MBF、MFR、k2和VD预测存活心肌的效能。结果显示各参数AUC为0.520至0.635,诊断效能低至中等;但静息MBF低于0.45 mL·min-1·g-1时,可安全推迟FDG-PET存活心肌检测,灵敏度96%、特异度12%。

要点

  • 定量NH3 PET参数预测存活心肌的AUC为0.520至0.635,效能低至中等。
  • 静息MBF低于0.45 mL·min-1·g-1时,可安全推迟FDG-PET存活心肌检测。
  • 该阈值下灵敏度96%、特异度12%,适用于缺血性心肌病人群。

核心结论

  • 定量NH3 PET参数预测缺血性心肌病存活心肌的诊断效能为低至中等。
  • 静息MBF低于0.45 mL·min-1·g-1时可安全推迟FDG-PET存活心肌检测。

研究设计与样本

  • 连续纳入180例缺血性心肌病患者,按节段水平将心肌分为正常、缺血、冬眠和瘢痕。
  • 从动态图像衍生应力MBF、静息MBF和k2,并计算MFR和VD。
  • 以FDG PET为存活心肌参考标准。

主要发现

  • 各心肌组织类型间所有参数均有显著差异。
  • 应力MBF、静息MBF、MFR、k2和VD的AUC分别为0.564(95% CI 0.527-0.601)、0.635(0.599-0.671)、0.553(0.516-0.591)、0.520(0.482-0.559)和0.560(0.522-0.597)。
  • 广义线性混合模型正确分类81%的瘢痕为存活心肌(冬眠心肌)。
  • 静息MBF阈值设为0.45 mL·min-1·g-1预测存活心肌时,灵敏度和特异度分别为96%和12%。

关键数值与推荐

  • 静息MBF预测存活心肌的阈值为0.45 mL·min-1·g-1,灵敏度96%、特异度12%。
  • 应力MBF、静息MBF、MFR、k2和VD的AUC分别为0.564、0.635、0.553、0.520和0.560。

临床怎么用

  • 静息MBF低于0.45 mL·min-1·g-1时可安全推迟FDG-PET存活心肌检测。
  • 定量NH3 PET参数不宜单独用于存活心肌判定,需结合FDG-PET。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: Positron emission tomography (PET) integrating assessment of perfusion with 13N-ammonia (NH3) and viability with 18F-fluorodeoxyglucose (FDG) has high accuracy to identify viable, hibernating myocardium. We tested whether quantification of myocardial blood flow (MBF) and washout (k2) can predict myocardial viability using FDG as standard of reference. METHODS: In 180 consecutive patients with ischemic cardiomyopathy, myocardium was categorized on a segment-level into normal, ischemic, hibernating, and scar. From dynamic images, stress MBF, rest MBF, and k2 were derived and myocardial flow reserve (MFR) and volume of distribution (VD) were calculated. RESULTS: Across myocardial tissues, all parameters differed significantly. The area under the curve (AUC) was 0.564 (95% CI 0.527-0.601), 0.635 (0.599-0.671), 0.553 (0.516-0.591), 0.520 (0.482-0.559), and 0.560 (0.522-0.597) for stress MBF, rest MBF, MFR, k2, and VD. The generalized linear mixed model correctly classified 81% of scar as viable, hibernating myocardium. If the threshold of rest MBF to predict viability was set to 0.45 mL·min-1·g-1, sensitivity and specificity were 96% and 12%, respectively. CONCLUSION: Quantitative NH3 PET parameters have low to moderate diagnostic performance to predict viability in ischemic cardiomyopathy. However, if rest MBF falls below 0.45 mL·min-1·g-1, viability testing by FDG-PET may be safely deferred.

来源:J Nucl Cardiol,查看原文。版权归原作者所有。

引用

  1. Benz DC, Ferro P, Safa N, et al. Role of quantitative myocardial blood flow and 13N-ammonia washout for viability assessment in ischemic cardiomyopathy. J Nucl Cardiol. 2019. PMID: 30895563. doi:10.1007/s12350-019-01684-1

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。