文献速递肿瘤 PET/CT

食管/胃食管癌18F-FDG PET/MRI影像组学特征与同期转移的探索性研究

Exploratory radiomic features from integrated 18F-fluorodeoxyglucose positron emission tomography/magnetic resonance imaging are associated with contemporaneous metastases in oesophageal/gastroesophageal cancer.
PubMed 文献 · Eur J Nucl Med Mol Imaging · 2019-03-27

本研究探索食管/胃食管癌患者18F-FDG PET/MRI影像组学特征与同期转移的关联。20例患者接受分期PET/MRI,提取肿瘤全体积的一阶直方图和二阶灰度共生矩阵特征。结果发现低二阶SUV熵联合高二阶ADC熵与转移显著相关(MANOVA P<0.001,灵敏度、特异度、PPV、NPV、准确率均为80%),优于单独SUVmax、ADCmean或最大径。

要点

  • 低SUV熵联合高ADC熵鉴别转移的灵敏度、特异度、准确率均为80%。
  • SUVmax灵敏度仅30%,ADCmean灵敏度20%,最大径灵敏度10%。
  • 该影像组学特征有望作为食管/胃食管癌转移的初筛标志物。

核心结论

  • 低二阶SUV熵联合高二阶ADC熵与食管/胃食管癌同期转移高患病率相关,是有前景的初步标志物。

研究设计与样本

  • 经IRB批准并知情同意后,患者接受分期18F-FDG PET/MRI,注射剂量326±28 MBq,摄取时间156±23 min。
  • 对肿瘤全体积计算PET SUV及MRI T1-W、T2-W、DWI、ADC图像的一阶直方图和二阶灰度共生矩阵特征。
  • 采用K-means聚类评估特征对与转移的相关性,并用MANOVA评估组间统计可分性。

主要发现

  • 最终纳入20例患者(18男2女,中位年龄67岁,范围52-86岁),其中10例有转移。
  • 低二阶SUV熵联合高二阶ADC熵是区分转移患者的最佳特征对,MANOVA P<0.001。
  • 该特征对灵敏度80%、特异度80%、PPV 80%、NPV 80%、准确率80%。
  • SUVmax灵敏度30%、特异度80%、PPV 60%、NPV 53%、准确率55%。
  • ADCmean灵敏度20%、特异度70%、PPV 40%、NPV 47%、准确率45%;肿瘤最大径灵敏度10%、特异度90%、PPV 50%、NPV 50%、准确率50%。

关键数值与推荐

  • 低二阶SUV熵联合高二阶ADC熵判别转移的MANOVA P<0.001,灵敏度80%、特异度80%、PPV 80%、NPV 80%、准确率80%。

临床怎么用

  • 对于食管/胃食管癌分期患者,可探索性提取原发灶全体积的SUV熵和ADC熵辅助评估同期转移风险。
  • 该特征对较传统SUVmax、ADCmean和最大径显示出更高的灵敏度和准确率,但需进一步验证。

局限性

  • 样本量小(共20例,转移10例),为探索性研究。
  • 单中心设计,结果需外部验证。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: The purpose of this study was to determine if 18F-fluorodeoxyglucose positron emission tomography/magnetic resonance imaging (18F-FDG PET/MRI) features are associated with contemporaneous metastases in patients with oesophageal/gastroesophageal cancer. METHODS: Following IRB approval and informed consent, patients underwent a staging PET/MRI following 18F-FDG injection (326 ± 28 MBq) and 156 ± 23 min uptake time. First-order histogram and second-order grey level co-occurrence matrix features were computed for PET standardized uptake value (SUV) and MRI T1-W, T2-W, diffusion weighted (DWI) and apparent diffusion coefficient (ADC) images for the whole tumour volume. K-means clustering assessed the correlation of feature-pairs with metastases. Multivariate analysis of variance (MANOVA) was performed to assess the statistical separability of the groups identified by feature-pairs. Sensitivity (SN), specificity (SP), positive predictive value (PPV), negative predictive value (NPV), and accuracy (ACC) were calculated for these features and compared with SUVmax, ADCmean and maximum diameter alone for predicting contemporaneous metastases. RESULTS: Twenty patients (18 males, 2 female; median 67 years, range 52-86) comprised the final study cohort; ten patients had metastases. Lower second-order SUV entropy combined with higher second-order ADC entropy were the best feature-pair for discriminating metastatic patients, MANOVA p value <0.001 (SN = 80%, SP = 80%, PPV = 80%, NPV = 80%, ACC = 80%). SUVmax (SN = 30%, SP = 80%, PPV = 60%, NPV = 53%, ACC = 55%), ADCmean (SN = 20%, SP = 70%, PPV = 40%, NPV = 47%, ACC = 45%) and tumour maximum diameter (SN = 10%, SP = 90%, PPV = 50%, NPV = 50%, ACC = 50%) had poorer sensitivity and accuracy. CONCLUSION: High ADC entropy combined with low SUV entropy is associated with a higher prevalence of metastases and a promising initial signature for future study.

来源:Eur J Nucl Med Mol Imaging,查看原文。版权归原作者所有。

引用

  1. Baiocco S, Sah BR, Mallia A, et al. Exploratory radiomic features from integrated 18F-fluorodeoxyglucose positron emission tomography/magnetic resonance imaging are associated with contemporaneous metastases in oesophageal/gastroesophageal cancer. Eur J Nucl Med Mol Imaging. 2019. PMID: 30919055. doi:10.1007/s00259-019-04306-7

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。