文献速递心脏核医学

门控SPECT相位分析对心脏结节病预后的预测价值

Prognostic value of phase analysis on gated single photon emission computed tomography in patients with cardiac sarcoidosis.
PubMed 文献 · J Nucl Cardiol · 2019-02-27

中位BW为56°,BW与LVEF呈强负相关、与SRS呈正相关,高BW组MACE年发生率显著高于低BW组,多因素分析显示BW是MACE的独立预测因子。

要点

  • 门控SPECT相位分析带宽(BW)与LVEF强负相关、与SRS正相关。
  • 高BW组(>56°)MACE年发生率15.1%,显著高于低BW组的4.4%。
  • BW是心脏结节病患者MACE的独立预测因子(P=0.015)。

核心结论

  • 门控SPECT相位分析是心脏结节病患者主要不良心脏事件的显著且独立预测因子。

研究设计与样本

  • 患者同期接受18F-FDG PET/CT与心电图门控SPECT检查。
  • FDG PET分析测量心脏代谢体积(CMV)与总病灶糖酵解(TLG)。
  • SPECT评估LVEF、静息总评分(SRS)与带宽(BW)。

主要发现

  • BW中位数为56°(IQR 40-95)。
  • BW与LVEF呈强负相关(r=-0.60,P<0.0001)。
  • BW与SRS呈正相关(r=0.82,P<0.0001)。
  • BW与CMV或TLG之间无显著相关性。
  • Kaplan-Meier曲线显示高BW组(BW>56°)MACE发生率显著高于低BW组(BW≤56°)(15.1%/年 vs. 4.4%/年,P=0.025)。

关键数值与推荐

  • 多因素分析中BW是MACE的显著独立预测因子(P=0.015)。
  • 高BW定义为BW>56°,低BW定义为BW≤56°。

临床怎么用

  • 对心脏结节病患者可考虑行门控SPECT相位分析评估BW,辅助MACE风险分层。
  • BW升高提示左室收缩不同步及不良预后风险增加。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: We aimed to determine the correlation between phase analysis, reflecting the heterogeneity of perfusion defects, and the dyssynchrony of the left ventricle wall motion, and adverse cardiac events in cardiac sarcoidosis (CS) patients. METHODS: Fifty-seven consecutive patients with diagnosed CS (64 [IQR 55-71] years old, 14 males), who underwent 18F-FDG PET/CT and ECG-gated SPECT, were studied. FDG PET was analysed to measure cardiac metabolic volume (CMV), and total lesion glycolysis (TLG). The SPECT findings, such as LVEF, Summed Rest Score (SRS), bandwidth (BW) were evaluated. RESULTS: The median of BW was 56° (IQR 40-95). BW showed a strong inverse correlation with LVEF (r = - 0.60, P < 0.0001), and positive correlation with SRS (r = 0.82, P < 0.0001). However, there were no significant correlations between BW and CMV or TLG. The Kaplan-Meier curves revealed a significantly higher rate of MACE in the high BW group (BW > 56°) than the low BW group (BW ≤ 56°) (15.1%/years vs. 4.4%/years, P = 0.025). In multivariable analysis, BW was a significant independent predictor of MACE (P = 0.015). CONCLUSION: Phase analysis on gated SPECT was a significant and independent predictor of MACE in patients with CS.

来源:J Nucl Cardiol,查看原文。版权归原作者所有。

引用

  1. Koyanagawa K, Naya M, Aikawa T, et al. Prognostic value of phase analysis on gated single photon emission computed tomography in patients with cardiac sarcoidosis. J Nucl Cardiol. 2019. PMID: 30815835. doi:10.1007/s12350-019-01660-9

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。