文献速递心脏核医学

年轻健康志愿者两次82Rb-PET/CT扫描间LVEF、左室容积和左室质量的可重复性:两种商用软件包的比较

Reproducibility of LVEF, LV volumes, and LV mass between Rubidium-82 PET/CT scans in young healthy volunteers using two commercially available software packages.
PubMed 文献 · J Nucl Cardiol · 2019-03-27

结果显示两次扫描间各参数可重复性高,但两种软件包间所有功能参数均存在显著差异。

要点

  • 两次82Rb-PET/CT扫描间LVEF、ESV、EDV和左室质量可重复性高。
  • Corridor4DM与QGS两种软件包间所有功能参数均存在显著差异。
  • 同一研究及比较绝对值时应使用同一软件包。

核心结论

  • 82Rb-PET/CT测量LVEF、ESV、EDV和左室质量在两次扫描间可重复性高。
  • 两种商用软件包间功能参数一致性差,研究中和比较绝对值时应使用同一软件包。

研究设计与样本

  • 每名志愿者接受两次82Rb-PET/CT静息和腺苷负荷扫描,获取整体功能参数。
  • 使用Corridor4DM(4DM)和定量门控SPECT(QGS)两种软件进行分析。

主要发现

  • 两次扫描间所有参数均显示高可重复性,两种软件包均如此。

临床怎么用

  • 临床和研究中可使用82Rb-PET/CT测量整体功能参数,但同一研究内及比较绝对值时应固定使用同一软件包。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Global functional parameters are available from electrocardiographic gated Rubidium-82 positron emission tomography/computed tomography (82Rb-PET/CT). However, the reproducibility of these data is not clarified. We aimed to investigate reproducibility of left ventricular ejection fraction (LVEF), endsystolic volume (ESV), enddiastolic volume (EDV), and left ventricular (LV) mass between two scans and between two commercially available software packages. METHODS AND RESULTS: Forty healthy young volunteers underwent two 82Rb-PET/CT rest and adenosine stress scans obtaining global functional parameters. Corridor4DM (4DM) and Quantitative Gated SPECT (QGS) were used for analyses. Mean (± SD) age was 24 ± 4 years and 50% were men. High reproducibility of all parameters was found between scans and this was true for both software packages. LVEF at rest with 4DM: mean difference (95% CI) - 1.1 (- 3.0 to 0.8), P = .25, limits of agreement: - 12.8 to 10.6. Significant differences were found between software packages on all functional parameters (P < .0001). CONCLUSION: High reproducibility was found between scans when measuring LVEF, ESV, EDV, and LV mass from 82Rb-PET/CT. However, concordance between parameter measures was poor when comparing the two software packages. Thus, global functional parameter measures are reliable, but the same software package should be used within a study and when comparing absolute values.

来源:J Nucl Cardiol,查看原文。版权归原作者所有。