文献速递核素与放射性配体治疗肿瘤 PET/CT

外部冷却对腮腺摄取177Lu-PSMA的影响

Effect of External Cooling on 177Lu-PSMA Uptake by the Parotid Glands.
PubMed 文献 · J Nucl Med · 2019-03-08

该研究纳入19例首次接受177Lu-PSMA-617治疗的转移性去势抵抗性前列腺癌患者,比较右侧腮腺冰袋冷却与左侧未冷却的摄取差异。结果显示冷却与未冷却腮腺在SUVmax、SUVmean及PRLT后4h和24h计数、体积上均无显著差异(P>0.05),提示外部冷却不降低腮腺对177Lu-PSMA-617的摄取。

要点

  • 冰袋外部冷却不减少腮腺对177Lu-PSMA-617的摄取。
  • 冷却与未冷却腮腺的SUVmax、SUVmean及计数差异均无统计学意义(P>0.05)。
  • 该研究为19例患者的小样本自身对照研究,结论需谨慎解读。

核心结论

  • 外部冷却不降低腮腺对177Lu-PSMA-617的摄取。

研究设计与样本

  • 研究纳入19例首次转诊接受177Lu-PSMA-617治疗的转移性去势抵抗性前列腺癌患者,平均年龄72.9岁,治疗前均行68Ga-PSMA-11 PET/CT。
  • 每位患者右侧腮腺固定冰袋约5小时,固定后1小时给予PRLT,PRLT后4小时行头颈部SPECT/CT,PRLT后4小时和24小时行全身平面显像。

主要发现

  • PRLT前68Ga-PSMA-11 PET/CT显示左右腮腺SUVmax和SUVmean无显著差异(P>0.05)。
  • PRLT后4小时和24小时平面显像显示冷却与未冷却腮腺计数无显著差异(P>0.05)。
  • PRLT后4小时SPECT/CT显示冷却与未冷却腮腺计数和体积无显著差异(P>0.05)。

临床怎么用

  • 基于该研究,冰袋外部冷却不能作为减少腮腺177Lu-PSMA-617摄取的有效措施。

局限性

  • 样本量较小,仅19例患者,结论需更大样本验证。
  • 冷却仅施加于右侧腮腺,左侧作为自身对照,但未报告冷却对肿瘤摄取或全身分布的影响。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

Recent years have seen the start of treatment of metastatic castration-resistant prostate cancer with prostate-specific membrane antigen (PSMA)-targeted radioligand therapy (PRLT), especially 177Lu-PSMA-617. However, PRLT has side effects on the salivary glands that limit the safety of the treatment. The current study aimed to show the effect of external cooling with ice packs on 177Lu-PSMA-617 uptake by the parotid glands (PGs). Methods: The study included 19 patients (mean age, 72.9 y) with metastatic castration-resistant prostate cancer who had been referred for the first time for 177Lu-PSMA-617 treatment and underwent pretreatment 68Ga-PSMA-11 PET/CT. Before the initiation of PRLT, the SUVmax and SUVmean of the right and left PGs were measured on 68Ga-PSMA PET/CT. Frozen ice packs were then affixed over the right PG of each patient for approximately 5 h; 1 h after they were affixed, PRLT was administered. At 4 h after PRLT, head-and-neck SPECT/CT was performed, and at both 4 and 24 h after PRLT, whole-body planar scintigraphy was performed. Regions and volumes of interest were applied for the right and left PGs, and the counts and volumes were determined. Results: Before PRLT, 68Ga-PSMA-11 PET/CT showed no significant difference in SUVmax or SUVmean between the right and left PGs (P > 0.05). At 4 and 24 h after PRLT, planar imaging showed no significant difference in counts between the cooled and noncooled PGs (P > 0.05). Furthermore, at 4 h after PRLT, SPECT/CT showed no significant difference in counts or volumes between the cooled and noncooled PGs (P > 0.05). Conclusion: External cooling does not reduce uptake of 177Lu-PSMA-617 by the PGs.

来源:J Nucl Med,查看原文。版权归原作者所有。

引用

  1. Yilmaz B, Nisli S, Ergul N, et al. Effect of External Cooling on 177Lu-PSMA Uptake by the Parotid Glands. J Nucl Med. 2019. PMID: 30850503. doi:10.2967/jnumed.119.226449

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。