文献速递心脏核医学

动态铷-82 PET 心肌血流量化无需逐帧衰减校正

No need for frame-wise attenuation correction in dynamic Rubidium-82 PET for myocardial blood flow quantification.
PubMed 文献 · J Nucl Cardiol · 2019-02-21

本研究纳入 64 例连续接受瑞加腺苷负荷铷-82 PET-CT 检查患者中 31 例出现心肌蠕变者,比较单次 PET-CT 对齐与逐帧对齐两种衰减校正方法对心肌血流量(MBF)测定的影响。结果显示逐帧配准未改变 MBF 测量值(P ≥ .07),错位程度与 MBF 差异无相关性(P ≥ .58)。结论认为动态铷-82 PET 量化 MBF 无需逐帧衰减校正,单次对齐已足够。

要点

  • 瑞加腺苷负荷下约半数患者出现心肌蠕变,可致 PET 与 CT 错位。
  • 逐帧 PET-CT 配准与单次对齐相比,MBF 测量值无显著差异。
  • 错位程度与 MBF 差异无相关性,单次对齐即可满足 MBF 量化。

核心结论

  • 动态铷-82 PET 量化 MBF 无需逐帧衰减校正,单次 PET-CT 对齐已足够。

研究设计与样本

  • 从 64 例连续接受瑞加腺苷负荷铷-82 PET-CT 检查的患者中纳入 31 例出现心肌蠕变者。
  • 对每例患者分别采用单次 PET-CT 对齐与逐帧对齐两种衰减校正方法重建图像。
  • 量化 PET-CT 错位程度,并计算三个血管 territory 及整体心肌的 MBF,比较两种方法间的差异。

主要发现

  • 心肌蠕变导致的错位幅度为尾-颅方向 13.8 ± 4.5 mm、内-外侧方向 1.8 ± 2.1 mm、前-后方向 2.5 ± 1.8 mm。
  • 逐帧 PET-CT 配准未导致 MBF 测量值出现差异(P ≥ .07)。
  • 错位幅度与 MBF 差异之间无相关性(P ≥ .58)。

临床怎么用

  • 对出现心肌蠕变的患者,动态铷-82 PET 量化 MBF 时可沿用单次 PET-CT 对齐进行衰减校正,无需逐帧处理。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Regadenoson-induced stress causes a repositioning of the heart, myocardial creep, in half of the patients undergoing Rubidium-82 (Rb-82) positron emission tomography (PET). As a result, misalignment of dynamic PET and computer tomography (CT) may occur, possibly affecting CT-based attenuation correction (AC) and thereby PET-based myocardial blood flow (MBF) quantification. Our aim was to determine the need for frame-wise PET-CT AC to obtain reliable MBF measurements. METHODS: 31 Out of 64 consecutive patients had myocardial creep during regadenoson-induced stress Rb-82 PET-CT and were included. Prior to PET image reconstruction, we applied two AC methods; single PET-CT alignment and frame-wise alignment in which PET time-frames with myocardial creep were individually co-registered with CT. The PET-CT misalignment was then quantified and MBFs for the three vascular territories and whole myocardium were calculated and compared between both methods. RESULTS: The magnitude of misalignment due to myocardial creep was 13.8 ± 4.5 mm in caudal-cranial direction, 1.8 ± 2.1 mm in medial-lateral and 2.5 ± 1.8 mm in anterior-posterior direction. Frame-wise PET-CT registration did not result in different MBF measurements (P ≥ .07) and the magnitude of misalignment and MBF differences did not correlate (P ≥ .58). CONCLUSION: There is no need for frame-wise AC in dynamic Rb-82 PET for MBF quantification. Single alignment seems sufficient in patients with myocardial creep.

来源:J Nucl Cardiol,查看原文。版权归原作者所有。

引用

  1. van Dijk JD, Jager PL, Ottervanger JP, et al. No need for frame-wise attenuation correction in dynamic Rubidium-82 PET for myocardial blood flow quantification. J Nucl Cardiol. 2019. PMID: 30790203. doi:10.1007/s12350-019-01654-7

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。