CZT探测器同时双核素成像在急性心梗直接PCI后患者的可行性

Feasibility of simultaneous 99mTc-tetrofosmin and 123I-BMIPP dual-tracer imaging with cadmium-zinc-telluride detectors in patients undergoing primary coronary intervention for acute myocardial infarction.
PubMed 文献 · J Nucl Cardiol · 2019-01-02

结果显示单核素与双核素成像在整体及区域左室功能、灌注和脂肪酸代谢参数上高度一致(ICC多>0.91),视觉分析梗死及灌注-代谢不匹配的阅者间一致性显著(P<0.001),提示该CZT扫描仪用于同时双核素采集在临床场景中可行。

要点

  • 单核素与双核素成像的QGS和QPS定量值ICC均高(EF 0.98,SRS 0.95-0.97)。
  • 区域壁运动、壁增厚及静息评分在单双核素间可比(ICC>0.91)。
  • 视觉分析梗死和灌注-代谢不匹配的阅者间一致性显著(P<0.001)。

核心结论

  • CZT探测器下同时99mTc-TF/123I-BMIPP双核素成像与单核素模式在整体和区域左室功能、灌注及脂肪酸代谢定量值上高度可比,提示临床可行性。

主要发现

  • 单核素与双核素成像的QGS和QPS数据ICC均高: summed motion score 0.95,summed thickening score 0.94,ejection fraction 0.98,SRS 99mTc-TF 0.97、123I-BMIPP 0.95。
  • 基于冠状动脉供血区域的壁运动、壁增厚和静息评分在单双核素成像间可比(ICC>0.91)。
  • 视觉分析梗死和灌注-代谢不匹配的阅者间一致性在整体和区域左室均显著(P<0.001)。

临床怎么用

  • 对于急性心肌梗死直接PCI后患者,可考虑使用CZT探测器进行同时99mTc-TF/123I-BMIPP双核素采集,以获得与单核素模式一致的整体和区域左室功能、灌注及脂肪酸代谢信息。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Simultaneous dual-tracer imaging using isotopes with close photo-peaks may benefit from improved properties of cadmium-zinc-telluride (CZT)-based scanners. METHODS: Thirty patients having undergone primary percutaneous coronary intervention for acute myocardial infarction underwent single-(99mTc-tetrofosmin (TF) or 123I-BMIPP first) followed by simultaneous 99mTc-TF /123I-BMIPP dual-tracer imaging using a Discovery NM/CT 670 CZT. The values for the quantitative gated-SPECT (QGS) and the quantitative perfusion SPECT (QPS) were assessed. RESULTS: The intra-class correlation (ICC) coefficients between the single- and dual-tracer imaging were high in all the QGS and QPS data (Summed motion score: 0.95, summed thickening score: 0.94, ejection fraction: 0.98, SRS for 99mTc-TF: 0.97/ for 123I-BMIPP: 0.95). Wall motion, wall thickening and rest scores per coronary-territory-based regions were also comparable between the single- and dual imaging (ICC coefficient > 0.91). The interrater concordance in the visual analysis for the infarction and perfusion-metabolism mismatch was significant for the global and regional left ventricle (P < 0.001). CONCLUSION: The quantitative/semi-quantitative values for global and regional left-ventricular function, perfusion, and fatty acid metabolism were closely comparable between the dual-tracer imaging and the single-tracer mode. These data suggests the feasibility of the novel CZT-based scanner for the simultaneous 99mTc-TF /123I-BMIPP dual-tracer acquisitions in clinical settings.

来源:J Nucl Cardiol,查看原文。版权归原作者所有。

引用

  1. Yamada Y, Nakano S, Gatate Y, et al. Feasibility of simultaneous 99mTc-tetrofosmin and 123I-BMIPP dual-tracer imaging with cadmium-zinc-telluride detectors in patients undergoing primary coronary intervention for acute myocardial infarction. J Nucl Cardiol. 2019. PMID: 30603890. doi:10.1007/s12350-018-01585-9