文献速递骨显像与常规 SPECT

血池SPECT作为疼痛性全膝关节置换术骨SPECT/CT的一部分:验证与假体力学生物标志物的潜力

Bloodpool SPECT as part of bone SPECT/CT in painful total knee arthroplasty (TKA): validation and potential biomarker of prosthesis biomechanics.
PubMed 文献 · Eur J Nucl Med Mol Imaging · 2019-01-02

该回顾性研究比较了血池SPECT与平面显像在疼痛性全膝关节置换术(TKA)骨SPECT/CT中的评分者间一致性、置信度、假体结局及生物力学功能。共分析43例患者55个膝关节(中位随访17个月,翻修率21.8%),SPECT在24%的区域显著改善评分者间一致性(均P<0.05),整体置信度提高20%(P<0.001),并显示出与假体生存及假体旋转相关的特定摄取模式。结论认为血池SPECT优于平面评估,其独特摄取模式可能成为假体生存和生物力学功能的临床相关生物标志物。

要点

  • 血池SPECT在24%区域显著改善评分者间一致性(均P<0.05),整体置信度提高20%(P<0.001)。
  • SPECT在胫骨(P<0.001)、髌骨(P=0.009)和滑膜(P=0.040)评估中的预后价值优于平面显像。
  • 内旋股骨假体导致股骨后内侧(P=0.042)、前外侧(P=0.016)及髌骨外侧(P=0.011)摄取增加。

核心结论

  • 血池SPECT在疼痛性TKA评估中优于平面显像,其独特摄取模式可能成为假体生存和生物力学功能的临床相关生物标志物。

研究设计与样本

  • 回顾性研究,比较血池SPECT与平面对照图像,共分析43例患者55个膝关节,中位随访17个月,翻修率21.8%。
  • 四位评估者使用经验证的Bruderholz方案和5点量表对摄取进行分级,计算评分者间一致性和整体置信度评分,并进行变量聚类分析。

主要发现

  • SPECT在24%的区域显著改善评分者间一致性(均P<0.05),整体置信度提高20%(P<0.001)。
  • 区域摄取聚类分析显示SPECT改善了前后分离,并发现与假体生存相关的不同模式:股骨外侧(P=0.041)和胫骨内侧(P<0.001)。
  • SPECT在胫骨(P<0.001)、髌骨(P=0.009)和滑膜(P=0.040)评估中的预后价值优于平面显像。
  • 股骨假体内旋导致股骨后内侧(P=0.042)、前外侧(P=0.016)及髌骨外侧(P=0.011)区域摄取增加。
  • 胫骨假体内旋导致胫骨后外侧(P=0.026)、后内侧(P=0.005)及髌骨内侧(P=0.004)区域摄取增加。

关键数值与推荐

  • 使用经验证的Bruderholz方案和5点量表对摄取进行分级。
  • 血池SPECT改善了晚期SPECT/CT对胫骨内侧区域评估的预后价值。

临床怎么用

  • 在疼痛性TKA的骨SPECT/CT中,加入血池SPECT可提高评估一致性、置信度及预后判断能力。
  • 血池SPECT显示的特定摄取模式有助于识别假体生存和生物力学功能异常,如假体旋转。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To compare bloodpool SPECT with planar imaging in bone SPECT/CT of painful total knee arthroplasty (TKA) with respect to inter-rater agreement, confidence, prosthesis outcome, and biomechanical functioning. METHODS: Retrospective study of bloodpool SPECT and planar control images. Four raters used the validated Bruderholz scheme and a 5-point scale to grade uptake. Inter-rater agreement and overall confidence scores were calculated. Variable cluster analysis was performed to identify patterns of uptake, and associations between patterns and prosthesis outcome and biomechanical functioning were examined. RESULTS: In all, 55 knees in 43 patients were analyzed (median follow-up 17 months; revision rate 21.8%). SPECT significantly improved inter-rater agreement in 24% of regions (all P < 0.05) and overall confidence by 20% (P < 0.001). Regional uptake cluster analysis showed improved antero-posterior separation with SPECT, and distinct patterns associated with prosthesis survival in lateral femoral (P = 0.041) and medial tibial (P < 0.001) regions. The prognostic value of SPECT outperformed planar imaging for tibial (P < 0.001), patellar (P = 0.009), and synovial (P = 0.040) assessment. Internal femoral malrotation resulted in increased uptake in posteromedial (P = 0.042) and anterolateral (P = 0.016) femoral, and lateral patellar (P = 0.011) regions. Internal tibial malrotation increased uptake in posterolateral (P = 0.026) and posteromedial tibial (P = 0.005), and medial patellar regions (P = 0.004). Bloodpool SPECT improved the prognostic value of late-phase SPECT/CT for the assessment of the medial tibial region. CONCLUSIONS: Bloodpool SPECT outperforms planar assessment of painful TKAs and the identification of distinct uptake patterns make it a potentially clinically relevant biomarker of prosthesis survival and biomechanical functioning.

来源:Eur J Nucl Med Mol Imaging,查看原文。版权归原作者所有。

引用

  1. Verschueren J, Albert A, Carp L, et al. Bloodpool SPECT as part of bone SPECT/CT in painful total knee arthroplasty (TKA): validation and potential biomarker of prosthesis biomechanics. Eur J Nucl Med Mol Imaging. 2019. PMID: 30600341. doi:10.1007/s00259-018-4244-4

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。