室性消融成功的预测因素:存活心肌、神经支配还是不匹配?
结果显示PIM节段平均电压高于瘢痕区但低于正常区,PIM存在是LAVA的独立预测因素;消融后PIM值显著降低,尤其在消融应答者中。
要点
- PIM节段电压介于瘢痕与正常区之间,PIM存在是LAVA的独立预测因素。
- 消融后PIM值显著降低,主要因灌注静息总评分增加,在应答者中更明显。
- PIM或可关联室性心律失常基质并指导基质消融。
核心结论
- PIM可能与LAVA表达的室性心律失常基质相关,并可能为基质消融提供新指导。
- PIM显著降低可预测对消融的良好临床反应。
研究设计与样本
- 术前及消融后1个月行123I-MIBG/99mTc-替曲膦静息SPECT心肌成像。
- 采用17节段左室分析用于SPECT或左室EAM电压图,所有患者临床随访至少1年。
主要发现
- 消融前,PIM节段的平均电压高于瘢痕节段但低于正常区域。
- 特定左室区域存在PIM是LAVA的独立预测因素。
- 消融后PIM值显著降低,主要由于灌注静息总评分增加,尤其在消融应答者中。
关键数值与推荐
- PIM根据99mTc-替曲膦和123I-MIBG的节段分布定义。
- 采用17节段左室分析用于SPECT或左室EAM电压图。
- 所有患者临床随访至少1年。
临床怎么用
- SPECT评估的PIM可能用于识别LAVA区域,辅助室性心律失常基质消融靶点选择。
- 消融后PIM降低可能作为预测临床应答的影像学指标。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
AIMS: Sympathetic dys-innervation may play an important role in the development of post-ischemic ventricular arrhythmias (VA). Aim of this study was to prove that perfusion/innervation mismatch (PIM) evaluated by SPECT can identify areas of local abnormal ventricular activities (LAVA) on electroanatomic mapping (EAM). METHODS: Sixteen patients referred to post-ischemic VA catheter ablation underwent pre-procedural and 1-month post-ablation 123I-MIBG/99mTc-tetrofosmin rest SPECT myocardial imaging. PIM was defined according to the segmental distributions of 99mTc-tetrofosmin and 123I-MIBG. A 17-segment LV analysis was used for either SPECT or LV EAM voltage map. All patients were followed up clinically for at least 1 year. RESULTS: Before ablation, the mean voltage in the PIM segments was higher than in the scarred ones but lower than in the normal regions. The presence of PIM in a specific LV zone was an independent predictor of LAVA. After ablation, PIM value was significantly reduced, mainly due to an increase in perfusion summed rest score, in particular in patients that were responders to ablation. CONCLUSIONS: PIM may associate with VA substrate expressed by LAVA and might provide a novel guide for substrate ablation. A significant reduction of PIM could predict a positive clinical response to ablation.
引用
- Gimelli A, Menichetti F, Soldati E, et al. Predictors of ventricular ablation's success: Viability, innervation, or mismatch? J Nucl Cardiol. 2019. PMID: 30603891. doi:10.1007/s12350-018-01575-x
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。