文献速递神经核医学

机器学习联合DAT SPECT定量指标诊断帕金森综合征:不同感兴趣区设置的影响

Impact of a combination of quantitative indices representing uptake intensity, shape, and asymmetry in DAT SPECT using machine learning: comparison of different volume of interest settings.
PubMed 文献 · EJNMMI Res · 2019-01-28

结果显示SVM联合三种指标的AUC达0.988(Q)和0.994(V),优于单一指标,且不同VOI设置间诊断准确率无显著差异(p=0.48)。

要点

  • SVM联合SBR、PCR/FD和AI可提高PS诊断效能,AUC达0.988-0.994。
  • SBR-Q的AUC(0.978)优于SBR-V(0.906),FD-V(0.972)优于PCR-Q(0.837)。
  • 不同VOI设置(DaTQUANT vs DaTView)对联合诊断准确率无显著影响(p=0.48)。

核心结论

  • 基于SVM联合三种定量指标可改善PS的诊断性能,且该性能不受VOI设置和所用软件影响。

主要发现

  • SBR-Q、PCR-Q、AI-Q、SBR-V、FD-V、AI-V的AUC分别为0.978、0.837、0.802、0.906、0.972、0.829。
  • SBR-Q优于SBR-V(p=0.006),FD-V优于PCR-Q(p=0.0003),AI-Q与AI-V无显著差异(p=0.56)。
  • SVM-Q和SVM-V的AUC分别为0.988和0.994,两者诊断准确率无显著差异(p=0.48)。

关键数值与推荐

  • SBR-Q的AUC为0.978,SBR-V的AUC为0.906(p=0.006)。
  • FD-V的AUC为0.972,PCR-Q的AUC为0.837(p=0.0003)。
  • SVM-Q的AUC为0.988,SVM-V的AUC为0.994(p=0.48)。

临床怎么用

  • 在DAT SPECT诊断帕金森综合征时,可考虑联合SBR、PCR/FD和AI三种定量指标并用机器学习分类器提升诊断准确性。
  • 不同VOI设置软件得到的联合诊断效能相似,临床可根据可用软件选择。

局限性

  • 原文未报告研究局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: We sought to assess the machine learning-based combined diagnostic accuracy of three types of quantitative indices obtained using dopamine transporter single-photon emission computed tomography (DAT SPECT)-specific binding ratio (SBR), putamen-to-caudate ratio (PCR)/fractal dimension (FD), and asymmetry index (AI)-for parkinsonian syndrome (PS). We also aimed to compare the effect of two different types of volume of interest (VOI) settings from commercially available software packages DaTQUANT (Q) and DaTView (V) on diagnostic accuracy. METHODS: Seventy-one patients with PS and 40 without PS (NPS) were enrolled. Using SPECT images obtained from these patients, three quantitative indices were calculated at two different VOI settings each. SBR-Q, PCR-Q, and AI-Q were derived using the VOI settings from DaTQUANT, whereas SBR-V, FD-V, and AI-V were derived using those from DaTView. We compared the diagnostic value of these six indices for PS. We incorporated a support vector machine (SVM) classifier for assessing the combined accuracy of the three indices (SVM-Q: combination of SBR-Q, PCR-Q, and AI-Q; SVM-V: combination of SBR-V, FD-V, and AI-V). A Mann-Whitney U test and receiver-operating characteristics (ROC) analysis were used for statistical analyses. RESULTS: ROC analyses demonstrated that the areas under the curve (AUC) for SBR-Q, PCR-Q, AI-Q, SBR-V, FD-V, and AI-V were 0.978, 0.837, 0.802, 0.906, 0.972, and 0.829, respectively. On comparing the corresponding quantitative indices between the two types of VOI settings, SBR-Q performed better than SBR-V (p = 0.006), whereas FD-V performed better than PCR-Q (p = 0.0003). No significant difference was observed between AI-Q and AI-V (p = 0.56). The AUCs for SVM-Q and SVM-V were 0.988 and 0.994, respectively; the two different VOI settings displayed no significant differences in terms of diagnostic accuracy (p = 0.48). CONCLUSION: The combination of the three indices obtained using the SVM classifier improved the diagnostic performance for PS; this performance did not differ based on the VOI settings and software used.

来源:EJNMMI Res,查看原文。版权归原作者所有。

引用

  1. Iwabuchi Y, Nakahara T, Kameyama M, et al. Impact of a combination of quantitative indices representing uptake intensity, shape, and asymmetry in DAT SPECT using machine learning: comparison of different volume of interest settings. EJNMMI Res. 2019. PMID: 30689072. doi:10.1186/s13550-019-0477-x

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。