相位分析:SPECT 左室不同步的度数与毫秒可否互换?
该研究纳入 399 例接受正常负荷 SPECT 心肌灌注显像的患者,用 QGS 软件计算带宽和标准差,分析心率等与相位变量的关系。结果显示度数与时间测得的带宽相关但不完全可互换(相关系数 0.87,P < .001),心率主要影响时间测量而非度数测量。
要点
- 相位分析度数与毫秒测得的带宽不完全可互换,相关系数仅 0.87。
- 心率与时间测量的带宽和标准差强相关,与度数测量无关。
- 作者建议以度数表示的相位正常范围可能更稳健。
核心结论
- 在灌注正常且 QRS 时限正常的患者中,以度数测量的带宽与以毫秒测量的时间不能直接互换。
- 大部分差异可由心率解释,心率主要影响时间测量而非度数测量。
- 作者提出以度数测量的相位正常范围可能更稳健,尽管对心内科医生不够直观。
研究设计与样本
- 399 例患者接受锝-99m-替曲膦正常负荷 SPECT 心肌灌注显像,使用 QGS 软件计算带宽和标准差。
- 分析心率、年龄、性别、负荷方式和射血分数与相位变量的关系,并排除 13 例传导异常(右/左束支传导阻滞和心室起搏)患者。
主要发现
- 心率与以时间测量的带宽和标准差强相关,与以度数测量时无关。
- 以时间和度数测量的带宽强相关但不完全(相关系数 0.87,P < .001)。
- 模型中加入心率可解释两种测量间的大部分残余变异,标准差结果类似。
关键数值与推荐
- 带宽以时间和度数测量间的相关系数为 0.87(P < .001)。
临床怎么用
- 解读相位分析结果时,不应将度数直接换算为毫秒,需考虑心率对时间测量的影响。
- 以度数表示的相位正常范围可能更稳健,可优先参考度数标准。
局限性
- 研究仅纳入灌注正常且 QRS 时限正常的患者,并排除了传导异常和心室起搏患者。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Phase analysis of gated single photon emission computed tomography (SPECT) myocardial perfusion scintigraphy provides a measure of left ventricular dyssynchrony and may have applications for identifying patients suitable for cardiac resynchronisation therapy. Phase analysis is typically described in degrees of cardiac cycle, less intuitive to cardiologists familiar with ECGs. We assessed the relationship between time and degrees, to determine whether they are interchangeable. METHODS AND RESULTS: 399 patients underwent normal stress-only SPECT myocardial perfusion imaging using Technetium-99m-tetrofosmin. Data analysis used QGS software (Cedars Sinai) calculating bandwidth and standard deviation. Heart rate, age, gender, stress modality, and ejection fraction were analyzed for their relation to phase variables. 13 patients were excluded for conduction abnormalities including right and left bundle branch block and ventricular pacing. Heart rate was strongly correlated to bandwidth and standard deviation measured in time, but unrelated when measured in degrees. Although bandwidth measured by time and degrees were strongly correlated with each other this relationship was not perfect (correlation coefficient 0.87, P < .001). The addition of heart rate to the model explained most of the residual variation between the two. The results for standard deviation were similar. CONCLUSION: In patients with normal myocardial perfusion and QRS duration bandwidth measured by degrees is not directly interchangeable with time in milliseconds. However most of the variation is explainable by heart rate, which predominantly affects measures of time rather than degrees. We would propose that although the values are less intuitive to cardiologists, normal ranges for phase measured in degrees are potentially more robust.
引用
- Barron AJ, Xavier R, Al-Housni M, et al. Phase analysis, a novel SPECT technique for left ventricular dyssynchrony: Are degrees and milliseconds interchangeable? J Nucl Cardiol. 2019. PMID: 30603893. doi:10.1007/s12350-018-01574-y
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。