该单中心前瞻性研究纳入34例临床证实或疑似髋/膝关节假体感染并拟行手术的患者,同期行68Ga-柠檬酸盐PET/CT与18F-FDG PET/CT,以术中所见和微生物分析为金标准。基于摄取模式判读,68Ga-柠檬酸盐PET/CT灵敏度92%、特异度88%、准确率91%,18F-FDG PET/CT分别为100%、38%、85%。68Ga-柠檬酸盐PET/CT的代谢体积在感染组显著高于非感染组,ROC曲线分析示MV切点370.86时灵敏度61.5%、特异度87.5%。

要点

  • 68Ga-柠檬酸盐PET/CT诊断假体感染特异度88%,高于18F-FDG PET/CT的38%。
  • 感染组68Ga-柠檬酸盐PET/CT代谢体积显著高于非感染组(422.45 vs 303.65 cm3,p=0.027)。
  • 68Ga-柠檬酸盐PET/CT的MV切点370.86对应灵敏度61.5%、特异度87.5%(AUC 0.75,95%CI 0.57-0.88,p=0.035)。

核心结论

  • 68Ga-柠檬酸盐PET/CT在检测假体关节感染方面可能对18F-FDG PET/CT起补充作用,其特征为更高的特异度并可能区分感染与无菌性炎症,尚需未来验证。

研究设计与样本

  • 单中心前瞻性研究,2016年1月至2017年10月纳入34例临床证实或疑似髋/膝关节假体感染并拟行手术的患者,所有患者均行68Ga-柠檬酸盐PET/CT并序贯行18F-FDG PET/CT,以术中所见和手术标本微生物分析为金标准。

主要发现

  • 26例(76%)患者诊断为感染。
  • 基于放射性示踪剂摄取模式判读,68Ga-柠檬酸盐PET/CT与18F-FDG PET/CT的灵敏度、特异度、准确率分别为92%、88%、91%与100%、38%、85%。
  • 使用68Ga-柠檬酸盐PET/CT时感染组代谢体积显著高于非感染组(422.45 vs 303.65 cm3,p=0.027),而18F-FDG PET/CT未见显著差异。
  • ROC曲线分析示MV切点370.86对应灵敏度61.5%、特异度87.5%(AUC 0.75,95%CI 0.57-0.88,p=0.035)。

关键数值与推荐

  • 诊断判读采用基于放射性示踪剂摄取模式的图像判读,并以感兴趣体积(VOIs)计算标准摄取值(SUVs)和代谢体积(MVs)进行定量分析。
  • 68Ga-柠檬酸盐PET/CT的MV切点370.86对应灵敏度61.5%、特异度87.5%(AUC 0.75,95%CI 0.57-0.88,p=0.035)。

临床怎么用

  • 对临床疑似假体关节感染、需鉴别感染与无菌性炎症并计划手术的患者,可考虑68Ga-柠檬酸盐PET/CT作为18F-FDG PET/CT的补充检查。

局限性

  • 结论属初步证据,需未来确认;研究为单中心前瞻性设计,样本量34例。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Prosthetic joint infections may lead to failures of total joint arthroplasty. Radionuclide imaging can play a diagnostic role in identifying such infections, which require two-stage exchange arthroplasty (instead of simple revision surgery performed in non-infected cases). Although 18F-FDG PET/CT has emerged as a novel diagnostic tool in this setting, the clinical usefulness of 68Ga-citrate PET/CT has not been previously investigated. This single-center prospective study was designed to address this issue. METHODS: Between January 2016 and October 2017, we examined 34 patients with clinically proven or suspected prosthetic hip/knee joint infections scheduled to undergo surgery. All patients underwent 68Ga-citrate PET/CT scans and sequential 18F-FDG PET/CT imaging for comparative purposes. Intraoperative findings and the results of microbiological analyses of surgical specimens served as gold standard. The diagnostic results were examined according to (1) image interpretation based on radiotracer uptake patterns and (2) quantitative analysis using volumes of interest (VOIs) to calculate standard uptake values (SUVs) and metabolic volumes (MVs). RESULTS: A total of 26 (76%) patients were diagnosed as having infections. Based on radiotracer uptake pattern criteria, the sensitivity, specificity, and accuracy of 68Ga-citrate PET/CT and 18F-FDG PET/CT were 92%, 88%, and 91% and 100%, 38%, and 85%, respectively. MV was significantly higher in the infected group when 68Ga-citrate PET/CT was used (422.45 vs. 303.65 cm3, p = 0.027), whereas no significant differences were observed on 18F-FDG PET/CT. According to receiver operating characteristic (ROC) curve analysis, a cut-off value of 370.86 for MV resulted in a sensitivity of 61.5% and a specificity of 87.5% (area under curve: 0.75, 95% confidence interval: 0.57-0.88, p = 0.035). CONCLUSIONS: Subject to future confirmation, our data provide preliminary evidence that 68Ga-citrate PET/CT may have a complimentary role to 18F-FDG PET/CT in detecting prosthetic joint infections, being characterized by a higher specificity and the possibility to discriminate between an infectious condition and sterile inflammation. TRIAL REGISTRATION: This prospective study was registered at clinicaltrials.gov (registration number: NCT02855190 ).