数字系统在54%患者中图像质量更优,且在26.5%的PET阳性患者中检出更多病灶,均为小于10毫米的病灶。
要点
- 数字PET/CT在54%患者中图像质量优于模拟系统。
- 数字系统在26.5%的PET阳性患者中检出更多病灶。
- 数字系统额外检出的病灶均小于10毫米。
核心结论
- 在肿瘤患者中,数字PET/CT较模拟PET/CT提供更好的图像质量和病灶检出能力,对亚厘米病灶更优。
研究设计与样本
- 由三名核医学医师采用4分制评估图像质量,并通过计数放射性摄取增高病灶评估检出能力。
主要发现
- 54%的患者中数字系统图像质量优于模拟系统(p=0.05,95%CI 44.2-63.5)。
- 两系统间病灶检出能力评分者一致率为97%,评分者间一致度κ=0.901(p<0.0001)。
- 两系统检出病灶总数无显著差异(数字5.03±10.6 vs 模拟4.53±10.29,p=0.7)。
- 83例PET阳性患者中22例(26.5%)数字系统检出更多病灶(p=0.05,95%CI 17.9-36.7),这些病灶均小于10毫米。
临床怎么用
- 在肿瘤PET/CT显像中,数字系统可能有助于检出亚厘米病灶,可优先考虑用于小病灶评估。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: The purpose of this study was to compare image quality and lesion detection capability between a digital and an analog PET/CT system in oncological patients. MATERIALS AND METHODS: One hundred oncological patients (62 men, 38 women; mean age of 65 ± 12 years) were prospectively included from January-June 2018. All patients, who accepted to be scanned by two systems, consecutively underwent a single day, dual imaging protocol (digital and analog PET/CT). Three nuclear medicine physicians evaluated image quality using a 4-point scale (-1, poor; 0, fair; 1, good; 2, excellent) and detection capability by counting the number of lesions with increased radiotracer uptake. Differences were considered significant for a p value <0.05. RESULTS: Improved image quality in the digital over the analog system was observed in 54% of the patients (p = 0.05, 95% CI, 44.2-63.5). The percentage of interrater concordance in lesion detection capability between the digital and analog systems was 97%, with an interrater measure agreement of κ = 0.901 (p < 0.0001). Although there was no significant difference in the total number of lesions detected by the two systems (digital: 5.03 ± 10.6 vs. analog: 4.53 ± 10.29; p = 0.7), the digital system detected more lesions in 22 of 83 of PET+ patients (26.5%) (p = 0.05, 95% CI, 17.9-36.7). In these 22 patients, all lesions detected by the digital PET/CT (and not by the analog PET/CT) were < 10 mm. CONCLUSION: Digital PET/CT offers improved image quality and lesion detection capability over the analog PET/CT in oncological patients, and even better for sub-centimeter lesions.
引用
- López-Mora DA, Flotats A, Fuentes-Ocampo F, et al. Comparison of image quality and lesion detection between digital and analog PET/CT. Eur J Nucl Med Mol Imaging. 2019. PMID: 30631910. doi:10.1007/s00259-019-4260-z
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。