文献速递神经核医学肿瘤 PET/CT

高级别与低级别胶质瘤的FDG和MET PET分布模式

Pattern of FDG and MET Distribution in High- and Low-Grade Gliomas on PET Images.
PubMed 文献 · Clin Nucl Med · 2019-01-01

该回顾性研究纳入44例高级别和19例低级别胶质瘤患者,比较FDG-PET与MET-PET的代谢指标及潜在浸润体积。结果显示肿瘤/正常皮层比值(T/N)鉴别效能最佳,联合T/N阈值和潜在浸润体积阈值可获得89%的诊断准确率。

要点

  • FDG-PET的T/N比值鉴别高低级别胶质瘤的AUC为0.800,MET-PET为0.773。
  • 潜在浸润体积鉴别高低级别胶质瘤:43.8±30.2 mL vs 14.0±12.6 mL,P=0.005。
  • 联合T/N(FDG≥0.9和/或MET≥3.0)与潜在浸润体积≥20.0 mL,诊断准确率89%。

核心结论

  • 在肿瘤核心T/N比值基础上评估核心周围潜在浸润体积,可能有助于鉴别高级别与低级别胶质瘤。

研究设计与样本

  • 回顾性识别同时接受FDG-PET、MET-PET及手术治疗的患者,所有肿瘤经组织学诊断,包括44例高级别和19例低级别胶质瘤。

主要发现

  • 以肿瘤值除以正常皮层值计算的T/N比值是鉴别高低级别胶质瘤最有效的指标(FDG-PET的AUC为0.800,MET-PET的AUC为0.773)。
  • 潜在浸润体积有效区分高低级别胶质瘤(43.8±30.2 mL vs 14.0±12.6 mL;P=0.005,t检验)。
  • 联合T/N(FDG-PET≥0.9和/或MET-PET≥3.0)与潜在浸润体积(≥20.0 mL)鉴别高低级别胶质瘤的诊断准确率为89%。

关键数值与推荐

  • FDG-PET的T/N比值鉴别高低级别胶质瘤的AUC为0.800。
  • MET-PET的T/N比值鉴别高低级别胶质瘤的AUC为0.773。
  • 潜在浸润体积鉴别高低级别胶质瘤:高级别43.8±30.2 mL,低级别14.0±12.6 mL,P=0.005。
  • 联合诊断阈值:FDG-PET T/N≥0.9和/或MET-PET T/N≥3.0,且潜在浸润体积≥20.0 mL,诊断准确率89%。

临床怎么用

  • 除评估肿瘤核心T/N比值外,可计算潜在浸润体积以辅助鉴别高低级别胶质瘤。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE OF THE REPORT: This study aimed to determine the most effective metabolic index of FDG-PET and MET-PET to differentiate high- and low-grade gliomas, and then to characterize tumor metabolism according to the 2016 WHO classification. We also developed a new calculation method of potential infiltrative tumor volume to overcome the current limitations of tumor evaluation according to metabolic index, which focuses solely on tumor core area. MATERIALS AND METHODS: Patients who underwent both FDG-PET and MET-PET, as well as surgical treatment, were retrospectively identified. All tumors were diagnosed histologically and included 44 high-grade and 19 low-grade gliomas. Metabolic indices of tumor-to-normal (T/N) ratio and maximum value within the tumor itself were compared between high- and low-grade tumors. A calculation method for potential infiltrative tumor volume was developed and compared between these 2 grades. RESULTS: T/N, calculated as tumor value divided by normal cortex value, was the most effective (area under the curve, 0.800 for FDG-PET; area under the curve, 0.773 for MET-PET) for differentiating high- and low-grade gliomas. Potential infiltrative volume effectively distinguished between high- and low-grade glioma (43.8 ± 30.2 mL vs 14.0 ± 12.6 mL; P = 0.005 [t test]). A combination of T/N, with a cutoff value of 0.9 or higher on FDG-PET and/or 3.0 or higher on MET-PET, and potential infiltrative volume, with a cutoff value of 20.0 mL or higher, provided a diagnostic accuracy of 89% in distinguishing high- from low-grade gliomas. CONCLUSIONS: Evaluation of potential infiltrative volume surrounding the tumor core area, in addition to the T/N ratio of the tumor core, may help distinguish between high- and low-grade gliomas.

来源:Clin Nucl Med,查看原文。版权归原作者所有。

引用

  1. Takahashi M, Soma T, Mukasa A, et al. Pattern of FDG and MET Distribution in High- and Low-Grade Gliomas on PET Images. Clin Nucl Med. 2019. PMID: 30688731. doi:10.1097/RLU.0000000000002460

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。