文献速递神经核医学

应用Centiloid标度定量[18F]氟比他班脑β-淀粉样蛋白的多处理方法研究

Centiloid scaling for quantification of brain amyloid with [18F]flutemetamol using multiple processing methods.
PubMed 文献 · EJNMMI Res · 2018-12-05

本研究对74名受试者(含24名年轻健康对照)的配对[11C]PiB和[18F]氟比他班PET扫描,采用标准Centiloid方法及PMOD、FSL、SPM8三种处理流程分析,并对10名AD患者进行重测。结果显示[18F]氟比他班与PiB结合强相关(R²=0.96),并推导出SUVR-Flute转换为Centiloid单位的直接转换方程;重测差异约2%,不同处理流程间无差异。

要点

  • [18F]氟比他班PET数据可转换为Centiloid单位,便于跨示踪剂和跨中心比较。
  • 标准Centiloid流程下[18F]氟比他班与PiB结合强相关(R²=0.96)。
  • 三种处理流程(SPM8、PMOD、FSL)的重测差异约2%,流程间无差异。

核心结论

  • [18F]氟比他班数据可表达为Centiloid单位,增强其在β-淀粉样蛋白成像临床和研究中的应用价值。
  • 标准Centiloid方法表明[18F]氟比他班相比PiB及其他β-淀粉样蛋白示踪剂具有良好性能。
  • 重测差异平均约2%,图像处理流程间无差异,Centiloid标度稳健且可在多个平台实施。

研究设计与样本

  • 研究分析了74名受试者的配对PiB和[18F]氟比他班扫描,包括24名年轻健康对照(37±5岁),采用标准Centiloid方法。
  • 同一批受试者还使用PMOD和FSL流程以及SPM8进行分析。
  • 对10名AD受试者使用每种流程进行了重测分析。

主要发现

  • 使用标准SPM8 Centiloid流程确定的SUVR显示[18F]氟比他班(Flute)与PiB结合强相关(SUVR-Flute = 0.77 × SUVR-PiB + 0.22,R² = 0.96)。
  • 标准Centiloid流程计算出SUVR-Flute转换为Centiloid单位(CL)的直接转换方程:CL = (121.42*SUVR-Flute) - 121.16。
  • 通过两种替代Centiloid流程分析数据,推导出与SPM8等效的标准化方程:PMOD为CL = (115.24*SUVR-Flute) - 107.86,FSL为CL = (120.32*SUVR-Flute) - 112.75。
  • 10名AD受试者的重测分析显示每种流程的差异约2%。

关键数值与推荐

  • SUVR-Flute与SUVR-PiB的线性关系:SUVR-Flute = 0.77 × SUVR-PiB + 0.22,R² = 0.96。
  • SUVR-Flute转换为Centiloid单位的方程:CL = (121.42*SUVR-Flute) - 121.16。
  • PMOD流程的等效方程:CL = (115.24*SUVR-Flute) - 107.86。
  • FSL流程的等效方程:CL = (120.32*SUVR-Flute) - 112.75。
  • 重测差异约2%。

临床怎么用

  • [18F]氟比他班PET数据可转换为Centiloid单位,用于临床和研究中的β-淀粉样蛋白成像定量比较。
  • 标准Centiloid方法可在SPM8、PMOD和FSL等多个平台实施,转换方程略有不同但重测差异小。
  • Centiloid标度有助于跨示踪剂和跨中心比较,支持阿尔茨海默病诊断、预后及抗淀粉样蛋白治疗监测。

局限性

  • 重测分析仅纳入10名AD受试者,样本量有限。
  • 研究未报告不同流程间差异的统计学检验结果。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

INTRODUCTION: A standardised method for quantifying β-amyloid PET tracers would allow comparison across different tracers and different sites. The development of the Centiloid scale has aimed to achieve this, applying a common scale to better aid the diagnosis and prognosis of Alzheimer's disease (AD) and to monitor anti-amyloid therapeutic interventions. Here, we apply the Centiloid method to [18F]flutemetamol and [11C]PiB (PiB, Pittsburgh compound B) PET images and derive the scaling factor to express their binding in Centiloids. METHODS: Paired PiB and [18F]flutemetamol scans for 74 subjects, including 24 young healthy controls (37 ± 5 years), were analysed using the standard Centiloid method. The same subjects were also analysed using PMOD- and FSL-based pipelines as well as SPM8. Test-retest analysis of 10 AD subjects was also performed with each pipeline. RESULTS: The standard uptake value ratios (SUVR), determined using the standard SPM8 Centiloid process, showed a strong correlation between [18F]flutemetamol (Flute) and PiB binding (SUVR-Flute = 0.77 × SUVR-PiB + 0.22, R2 = 0.96). Application of the standard Centiloid process allowed the calculation of a direct conversion equation for SUVR-Flute to Centiloid units (CL) (CL = (121.42*SUVR-Flute) - 121.16). Analysis of the data via the two alternate Centiloid pipelines allowed us to derive standardised, SPM8-equivalent equations for both PMOD (CL = (115.24*SUVR-Flute) - 107.86) and FSL (CL = (120.32*SUVR-Flute) - 112.75) respectively. Test-retest analysis of 10 AD subjects showed an approximate 2% difference for each pipeline. CONCLUSIONS: [18F]flutemetamol data can now be expressed in Centiloid units, enhancing its utility in clinical and research applications for β-amyloid imaging. The standard Centiloid method also demonstrates that [18F]flutemetamol has favourable performance compared with PiB and other β-amyloid tracers. Test-retest difference averaged 2%, with no difference between image processing pipelines. Centiloid scaling is robust and can be implemented on a number of platforms.

来源:EJNMMI Res,查看原文。版权归原作者所有。

引用

  1. Battle MR, Pillay LC, Lowe VJ, et al. Centiloid scaling for quantification of brain amyloid with [18F]flutemetamol using multiple processing methods. EJNMMI Res. 2018. PMID: 30519791. doi:10.1186/s13550-018-0456-7

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。