缺血性心肌病门控SPECT不同同步性参数重复性与多巴酚丁胺同步储备检测比较
熵的重复性(CCC 0.80)高于带宽(0.68)和相位标准差(0.75);
要点
- 熵的重复性优于带宽和相位标准差,更适合评估同步性。
- 低剂量多巴酚丁胺可平均改善带宽和熵,提示同步储备。
- 仅少数患者同步改善超出重复性95%CI,个体层面检测有限。
核心结论
- 低剂量多巴酚丁胺门控SPECT可通过带宽和熵记录缺血性心肌病患者的同步储备,且熵重复性更高。
主要发现
- 熵的Lin一致性相关系数(CCC)为0.80,高于带宽(0.68)和相位标准差(0.75)。
- 仅6例(带宽)和4例(熵)的改善超出重复性分析95%置信区间。
关键数值与推荐
- 重复性以Lin一致性相关系数评估:熵0.80、带宽0.68、相位标准差0.75。
- 同步储备判定为改善超出重复性分析95%置信区间。
临床怎么用
- 临床可优先采用熵评估缺血性心肌病同步性,因其重复性较高。
- 低剂量多巴酚丁胺门控SPECT可用于检测同步储备,但个体层面需结合重复性置信区间解读。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: This study aimed to determine whether the repeatability of dyssynchrony assessment using gated myocardial perfusion SPECT (GSPECT) allows the detection of synchrony reserve during low-dose dobutamine infusion. METHODS AND RESULTS: Sixty-one patients with ischemic cardiomyopathy and LV ejection fraction < 50% were prospectively included in 10 centers. Each patient underwent two consecutive rest GSPECT with 99mTc-labeled tracer (either tetrofosmin or sestamibi) to assess the repeatability of LV function and dyssynchrony parameters, followed by a GSECT acquisition during low-dose dobutamine infusion. LV dyssynchrony was assessed using QGS software through histogram bandwidth (BW), standard deviation of the phase (SD), and entropy. Repeatability was assessed with Lin's concordance correlation coefficient (CCC). Entropy showed a higher CCC (0.80) compared to BW (0.68) and SD (0.75). On average, dobutamine infusion yielded to improve both BW (P = .049) and entropy (P = .04) although significant improvements, setting outside the 95% confidence interval of the repeatability analysis, were documented in only 6 and 4 patients for BW and entropy, respectively. CONCLUSIONS: A synchrony reserve may be documented in patients with ischemic cardiomyopathy through the recording of BW and entropy with low-dose dobutamine GSPECT, with the additional advantage of a higher repeatability for entropy.
引用
- Legallois D, Marie PY, Franken PR, et al. Comparison of the dyssynchrony parameters recorded with gated SPECT in ischemic cardiomyopathy according to their repeatability at rest and to their ability to detect a synchrony reserve under dobutamine infusion. J Nucl Cardiol. 2018. PMID: 30515748. doi:10.1007/s12350-018-01546-2
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。