PubMed 文献 · J Nucl Cardiol · 2018-12-04

该研究纳入172例患者,比较正常心肌灌注显像组(133例)与缺血组(39例)的左室收缩不同步(LVD)和局部室壁运动异常(RWMA)。缺血组LVD带宽和标准差显著高于正常组;LVD灵敏度59%、特异度83%,RWMA灵敏度33%、特异度100%。结论认为缺血患者负荷后LVD由心肌顿抑所致,相位分析测量的LVD可作为识别缺血的辅助工具。

要点

  • 缺血组LVD带宽63±46、标准差26±15,均显著高于正常组。
  • LVD灵敏度59%、特异度83%;RWMA灵敏度33%、特异度100%。
  • 缺血患者负荷后LVD与心肌顿抑相关,可能辅助识别缺血。

核心结论

  • 缺血患者负荷后存在由心肌顿抑所致的左室收缩不同步,相位分析测量的LVD可能有助于识别缺血。

研究设计与样本

  • 单中心队列研究,纳入172例患者,分为正常MPS组(N=133)和MPS心肌缺血组(N=39)。
  • 评估SSS、SRS、SDS,通过相位分析评估LVD,通过目视分析评估RWMA。

主要发现

  • 正常组与缺血组SSS为0 vs 9.8±3.9(P=.0001),SDS为0 vs 9.8±3.9(P=.0001),SRS为0 vs 0(P=NS)。
  • 正常组与缺血组LVD带宽为36±14 vs 63±46(P=.0001),标准差为16±10 vs 26±15(P=.0001)。
  • 正常组LVD占16%、RWMA占0%(P=.0001);缺血组LVD占59%、RWMA占33%(P=.03)。
  • LVD灵敏度59%、RWMA灵敏度33%(P=.03);LVD特异度83%、RWMA特异度100%(P=.0001)。

临床怎么用

  • 在门控心肌灌注显像中可结合相位分析LVD评估,作为缺血识别的辅助指标。
  • LVD特异度83%低于RWMA的100%,解读时应结合灌注评分与临床情况。

局限性

  • 原文摘要未报告研究局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

INTRODUCTION: Left ventricular dyssynchrony (LVD) quantified by gated myocardial perfusion studies (MPS), through phase analysis (PA), has shown controversial results in myocardial stunning. OBJECTIVES: Assessment of LVD and regional wall motion abnormalities (RWMA) in normal and ischemic patients. METHODS: A cohort of 172 patients were studied. Summed Stress Score (SSS), Summed Resting Score (SRS), and Summed Difference Score (SDS) were evaluated. Group 1-patients with normal MPS (N = 133) and Group 2-patients with myocardial ischemia in the MPS (N = 39). LVD was evaluated through PA and RWM by visual analysis. RESULTS: SSS 0 vs 9.8 ± 3.9 P = .0001; SDS 0 vs 9.8 ± 3.9 P = .0001; SRS 0 vs 0 P = NS, in G1 and G2. Significant differences were found in LVD between G1 and G2, bandwidth 36 ± 14 vs 63 ± 46 P = .0001; standard deviation 16 ± 10 vs 26 ± 15 P = .0001. In G1, 16% had LVD vs RWMA in 0%, P = .0001 and in G2, 59% with LVD vs 33% with RWMA, P = .03. Sensitivity for LVD 59% and for RWMA 33%, P = .03 and specificity for LVD 83% and for RWMA 100%, P = .0001. CONCLUSION: Ischemic patients have LVD post-stress due to myocardial stunning. LVD measured by PA could be a useful tool to identify ischemia.

来源:J Nucl Cardiol,查看原文。版权归原作者所有。