重建方案对FDG-PET影像组学鉴别乳腺癌组织生物学特征的影响
高分辨率PSF乳腺重建的分类准确率达85.7%,高于全身PSF的67.8%和乳腺OSEM的73.8%。
要点
- 高分辨率PSF乳腺重建对Luminal与非Luminal乳腺癌分类准确率最高。
- 纹理特征Coarseness与ZLNU在三个预测模型中均为重要变量。
- 小病灶(MTV<3 ml)中PSF乳腺重建的Coarseness值范围更广。
核心结论
- 采用小体素矩阵和PSF建模的高分辨率乳腺PET采集可改善乳腺肿瘤的特征识别。
研究设计与样本
- 每例患者除标准PET成像(PSFWholeBody)外,另行高分辨率乳腺采集并以OSEM和PSF重建(OSEMbreast/PSFbreast)。
- 提取标准PET指标与纹理特征,用随机森林方法为每种重建方案构建肿瘤分类预测模型。
主要发现
- PSFWholeBody的VOI内体素数量中位数(四分位距)为130(43-271),低于OSEMbreast的316(167-1042)和PSFbreast的367(107-1221),p<0.0001。
- 使用LifeX软件可分析的患者数在PSFWholeBody、OSEMbreast、PSFbreast分别为28例(59%)、46例(98%)、42例(89%)。
- 匹配比较中PSFbreast对Luminal与非Luminal乳腺癌分类准确率达85.7%,PSFWholeBody为67.8%,OSEMbreast为73.8%。
- PSFbreast的准确率、灵敏度、特异度、PPV和NPV分别为85.7%、94.3%、42.9%、89.2%、60.0%。
- Coarseness在PSFWholeBody图像上与SUVmax相关(ρ=-0.526,p=0.005),在OSEMbreast(ρ=-0.183,p=0.244)和PSFbreast(ρ=-0.244,p=0.119)图像上不相关。
临床怎么用
- 在需用FDG-PET纹理特征鉴别乳腺癌Luminal与非Luminal亚型时,可优先考虑小体素矩阵联合PSF建模的高分辨率乳腺重建方案。
- 解读纹理特征(如Coarseness)时应考虑重建方案的影响,不同重建下其与SUVmax的相关性不同。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: The aim of this study is to determine if the choice of the 18F-FDG-PET protocol, especially matrix size and reconstruction algorithm, is of importance to discriminate between immunohistochemical subtypes (luminal versus non-luminal) in breast cancer with textural features (TFs). PROCEDURES: Forty-seven patients referred for breast cancer staging in the framework of a prospective study were reviewed as part of an ancillary study. In addition to standard PET imaging (PSFWholeBody), a high-resolution breast acquisition was performed and reconstructed with OSEM and PSF (OSEMbreast/PSFbreast). PET standard metrics and TFs were extracted. For each reconstruction protocol, a prediction model for tumour classification was built using a random forests method. Spearman coefficients were used to seek correlation between PET metrics. RESULTS: PSFWholeBody showed lower numbers of voxels within VOIs than OSEMbreast and PSFbreast with median (interquartile range) equal to 130 (43-271), 316 (167-1042), 367 (107-1221), respectively (p < 0.0001). Therefore, using LifeX software, 28 (59%), 46 (98%) and 42 (89%) patients were exploitable with PSFWholeBody, OSEMbreast and PSFbreast, respectively. On matched comparisons, PSFbreast reconstruction presented better abilities than PSFwholeBody and OSEMbreast for the classification of luminal versus non-luminal breast tumours with an accuracy reaching 85.7% as compared to 67.8% for PSFwholeBody and 73.8% for OSEMbreast. PSFbreast accuracy, sensitivity, specificity, PPV and NPV were equal to 85.7%, 94.3%, 42.9%, 89.2%, 60.0%, respectively. Coarseness and ZLNU were found to be main variables of importance, appearing in all three prediction models. Coarseness was correlated with SUVmax on PSFwholeBody images (ρ = - 0.526, p = 0.005), whereas it was not on OSEMbreast (ρ = - 0.183, p = 0.244) and PSFbreast (ρ = - 0.244, p = 0.119) images. Moreover, the range of its values was higher on PSFbreast images as compared to OSEMbreast, especially in small lesions (MTV < 3 ml). CONCLUSIONS: High-resolution breast PET acquisitions, applying both small-voxel matrix and PSF modelling, appeared to improve the characterisation of breast tumours.
引用
- Aide N, Salomon T, Blanc-Fournier C, et al. Implications of reconstruction protocol for histo-biological characterisation of breast cancers using FDG-PET radiomics. EJNMMI Res. 2018. PMID: 30594961. doi:10.1186/s13550-018-0466-5
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。