文献速递骨显像与常规 SPECT放射性药物与辐射防护

18F-FDG PET/CT诊断骨折相关感染的诊断准确性

The diagnostic accuracy of 18F-FDG PET/CT in diagnosing fracture-related infections.
PubMed 文献 · Eur J Nucl Med Mol Imaging · 2018-12-07

本研究回顾性纳入2011至2017年两家一级创伤中心疑似骨折相关感染(FRI)患者的18F-FDG PET/CT扫描,以至少两次深部代表性微生物培养或AO/EBJIS共识定义的临床确认征象为参考标准。定性评估的灵敏度0.89、特异度0.80、阳性预测值0.74、阴性预测值0.91、诊断准确性0.83;SUV测量联合定性评估的AUC为0.89,高于单独定性评估的0.84(p=0.007)。术后<1个月行PET/CT是假性结果的最强独立预测因素,绝对风险46%(95%CI 27-66%),而术后1-6个月为7%(95%CI 4-12%)。

要点

  • 定性评估18F-FDG PET/CT诊断FRI的准确性为0.83,阴性预测值达0.91。
  • SUV测量联合定性评估较单独定性评估提高诊断准确性(AUC 0.89 vs 0.84,p=0.007)。
  • 术后<1个月行PET/CT假性结果风险显著增高(46% vs 7%)。

核心结论

  • 定性评估18F-FDG PET/CT诊断FRI的准确性为0.83,阴性预测值0.91。
  • SUV测量联合定性评估较单独定性评估提供额外准确性。
  • 术后与PET/CT间隔<1个月与假性结果急剧增加相关。

研究设计与样本

  • 回顾性队列研究,纳入2011至2017年两家一级创伤中心疑似FRI并行18F-FDG PET/CT的患者。
  • 共纳入135例患者的156次18F-FDG PET/CT扫描。
  • 由两名核医学医师独立重新评估所有扫描。
  • 参考标准为至少两次深部代表性微生物培养结果或随访至少6个月期间FRI临床确认征象的存在/缺失(AO/EBJIS共识定义)。

主要发现

  • 定性评估的灵敏度0.89、特异度0.80、阳性预测值0.74、阴性预测值0.91、诊断准确性0.83。
  • 单独SUV诊断性能较低,但联合定性评估的AUC为0.89,单独定性评估为0.84(p=0.007)。
  • 术后<1个月行PET/CT是假性结果预测价值最高的独立变量,绝对风险46%(95%CI 27-66%)。
  • 术后1-6个月行PET/CT的患者假性结果绝对风险为7%(95%CI 4-12%)。

关键数值与推荐

  • FRI参考标准采用AO/EBJIS共识定义,基于至少两次深部代表性微生物培养或随访至少6个月的临床确认征象。
  • 定性评估18F-FDG PET/CT诊断FRI的灵敏度0.89、特异度0.80、阳性预测值0.74、阴性预测值0.91、准确性0.83。
  • SUV联合定性评估AUC 0.89,单独定性评估AUC 0.84,差异p=0.007。
  • 术后<1个月行PET/CT假性结果绝对风险46%(95%CI 27-66%),术后1-6个月为7%(95%CI 4-12%)。

临床怎么用

  • 18F-FDG PET/CT定性评估可用于疑似FRI的诊断,其高阴性预测值有助于排除感染。
  • 在定性评估基础上结合SUV测量可进一步提高诊断准确性。
  • 应避免在术后<1个月内行18F-FDG PET/CT评估FRI,以减少假性结果。

局限性

  • 本研究为回顾性队列研究。
  • 原文未报告其他局限性信息。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: 18F-Fluorodeoxyglucose positron emission tomography (18F-FDG PET/CT) is frequently used to diagnose fracture-related infections (FRIs), but its diagnostic performance in this field is still unknown. The aims of this study were: (1) to assess the diagnostic performance of qualitative assessment of 18F-FDG PET/CT scans in diagnosing FRI, (2) to establish the diagnostic performance of standardized uptake values (SUVs) extracted from 18F-FDG PET/CT scans and to determine their associated optimal cut-off values, and (3) to identify variables that predict a false-positive (FP) or false-negative (FN) 18F-FDG PET/CT result. METHODS: This retrospective cohort study included all patients with suspected FRI undergoing 18F-FDG PET/CT between 2011 and 2017 in two level-1 trauma centres. Two nuclear medicine physicians independently reassessed all 18F-FDG PET/CT scans. The reference standard consisted of the result of at least two deep, representative microbiological cultures or the presence/absence of clinical confirmatory signs of FRI (AO/EBJIS consensus definition) during a follow-up of at least 6 months. Diagnostic performance in terms of sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) was calculated. Additionally, SUVs were measured on 18F-FDG PET/CT scans. Volumes of interest were drawn around the suspected and corresponding contralateral areas to obtain absolute values and ratios between suspected and contralateral areas. A multivariable logistic regression analysis was also performed to identify the most important predictor(s) of FP or FN 18F-FDG PET/CT results. RESULTS: The study included 156 18F-FDG PET/CT scans in 135 patients. Qualitative assessment of 18F-FDG PET/CT scans showed a sensitivity of 0.89, specificity of 0.80, PPV of 0.74, NPV of 0.91 and diagnostic accuracy of 0.83. SUVs on their own resulted in lower diagnostic performance, but combining them with qualitative assessments yielded an AUC of 0.89 compared to an AUC of 0.84 when considering only the qualitative assessment results (p = 0.007). 18F-FDG PET/CT performed <1 month after surgery was found to be the independent variable with the highest predictive value for a false test result, with an absolute risk of 46% (95% CI 27-66%), compared with 7% (95% CI 4-12%) in patients with 18F-FDG PET/CT performed 1-6 months after surgery. CONCLUSION: Qualitative assessment of 18F-FDG PET/CT scans had a diagnostic accuracy of 0.83 and an excellent NPV of 0.91 in diagnosing FRI. Adding SUV measurements to qualitative assessment provided additional accuracy in comparison to qualitative assessment alone. An interval between surgery and 18F-FDG PET/CT of <1 month was associated with a sharp increase in false test results.

来源:Eur J Nucl Med Mol Imaging,查看原文。版权归原作者所有。

引用

  1. Lemans JVC, Hobbelink MGG, IJpma FFA, et al. The diagnostic accuracy of 18F-FDG PET/CT in diagnosing fracture-related infections. Eur J Nucl Med Mol Imaging. 2018. PMID: 30523391. doi:10.1007/s00259-018-4218-6

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。