使用Galligas和镓-68-MAA的PET/CT肺通气与灌注显像
综述指出,使用镓-68替代锝-99m、沿用常规V/Q显像的载体分子,可实现V/Q PET/CT显像;通气显像可用镓-68碳纳米颗粒(与Technegas同一合成装置),灌注显像可用镓-68大颗粒聚合白蛋白。V/Q PET/CT在图像采集上具有更高灵敏度、更高空间与时间分辨率及更优定量能力,可更准确描绘和定量区域肺功能,并可能改善肺栓塞诊断性能及用于肺癌术前评估、放疗计划、肺减容手术术前评估等。
要点
- 镓-68可替代锝-99m,沿用常规V/Q显像载体分子实现V/Q PET/CT。
- 通气用镓-68碳纳米颗粒,灌注用镓-68大颗粒聚合白蛋白。
- V/Q PET/CT图像采集灵敏度、空间与时间分辨率及定量能力更优。
核心结论
- V/Q PET/CT在图像采集上本质更优,具有更高灵敏度、更高空间与时间分辨率及更优定量能力,可更准确描绘和定量区域肺功能。
研究设计与样本
- 综述,未报告检索范围与样本量。
主要发现
- 通气显像可用镓-68碳纳米颗粒,使用与Technegas相同的合成装置。
- 灌注显像可用镓-68大颗粒聚合白蛋白。
- V/Q PET/CT额外优势包括缩短采集时间、呼吸门控采集及对人力资源影响更小。
- 对肺栓塞,V/Q PET/CT可能因更好表征缺损模式并准确定量血管阻塞范围而改善诊断性能。
关键数值与推荐
- 通气显像用镓-68碳纳米颗粒,灌注显像用镓-68大颗粒聚合白蛋白,均以镓-68替代锝-99m。
- 原文未报告具体剂量、阈值或诊断标准数值。
临床怎么用
- V/Q PET/CT可能用于肺栓塞诊断,更好表征缺损模式并定量血管阻塞范围。
- 区域通气与灌注功能图可能用于肺癌患者术前评估、放疗计划及肺减容手术术前评估。
局限性
- 原文未述局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
Ventilation/Perfusion (V/Q) positron emission tomography computed tomography (PET/CT) is now possible by substituting Technetium-99m (99mTc) with Gallium-68 (68Ga), using the same carrier molecules as conventional V/Q imaging. Ventilation imaging can be performed with 68Ga-carbon nanoparticles using the same synthesis device as Technegas. Perfusion imaging can be performed with 68Ga-macroaggregated albumin. Similar physiological processes can therefore be evaluated by either V/Q SPECT/CT or PET/CT. However, V/Q PET/CT is inherently a superior technology for image acquisition, with higher sensitivity, higher spatial and temporal resolution, and superior quantitative capability, allowing more accurate delineation and quantification of regional lung function. Additional advantages include reduced acquisition time, respiratory-gated acquisition, and a lower impact on human resources. V/Q PET imaging offers an opportunity to improve the accuracy and utility of V/Q imaging in various pulmonary conditions. For pulmonary embolism, V/Q PET/CT scan may improve the diagnostic performance of the test owing to a better characterization of the pattern of defects and allow an accurate quantification of the extent of vascular obstruction. Establishing an accurate functional map of the regional ventilation and perfusion in the lungs may be relevant in many other clinical situations, including preoperative assessment of the lung cancer patients, radiotherapy planning, or presurgical evaluation of patients undergoing lung volume reduction surgery.
引用
- Le Roux PY, Hicks RJ, Siva S, et al. PET/CT Lung Ventilation and Perfusion Scanning using Galligas and Gallium-68-MAA. Semin Nucl Med. 2018. PMID: 30545520. doi:10.1053/j.semnuclmed.2018.10.013
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。