该研究在55例连续患者中比较了IQ-SPECT(方法A和B,不同采集时间)与配备LEHR准直器的常规SPECT(方法C)所测左心室射血分数(LVEF)的一致性。Bland-Altman分析显示方法A与C的偏倚为3.8%,一致性界限(LA)为-9.3%至16.8%。结论指出LA区间宽度约30%,IQ与LEHR门控SPECT不可互换,IQ-SPECT测值在评估心脏功能状态时应仅谨慎使用。

要点

  • IQ-SPECT与LEHR常规SPECT测LVEF的偏倚为3.8%,LA为-9.3%至16.8%。
  • 方法B与C的一致性低于方法A与C,方法A与B比较一致性仅轻微改善。
  • LA区间宽度约30%,提示IQ与LEHR门控SPECT不可互换。

核心结论

  • IQ-SPECT与LEHR门控SPECT测得的LVEF一致性界限宽约30%,两者不可互换。
  • IQ-SPECT测值在评估心脏功能状态时应仅谨慎使用。

研究设计与样本

  • 在55例连续患者中行99mTc-tetrofosmin门控负荷MPI。
  • 患者接受两种序贯采集:方法A和方法B在Symbia-IQ SPECT上以不同采集时间进行;方法C在配备LEHR准直器的Ecam SPECT上进行。
  • 采用Bland-Altman分析法在三种方案的头对头比较中估计偏倚和一致性界限(LA)。

主要发现

  • 方法A与方法C比较LVEF的偏倚为3.8%,LA为-9.3%至16.8%。
  • 方法B与方法C之间的一致性仍较低。
  • 方法A与方法B比较时一致性仅轻微改善。

关键数值与推荐

  • 方法A与方法C比较LVEF的偏倚为3.8%,LA范围为-9.3%至16.8%。
  • LA区间宽度约30%。

临床怎么用

  • IQ-SPECT测得的LVEF值在评估心脏功能状态时应仅谨慎使用。

局限性

  • 原文未述局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The aim of the study was to assess the agreement between the left ventricular ejection fraction (LVEF) values obtained with IQ-SPECT and those obtained with a conventional gamma camera equipped with low-energy high-resolution (LEHR), considered as the method of reference. METHODS: Gated-stress MPI using 99mTc-tetrofosmin was performed in 55 consecutive patients. The patients underwent two sequential acquisitions (Method A and B) performed on Symbia-IQ SPECT with different acquisition times and one (Method C) on a Ecam SPECT equipped with LEHR collimators. The values of the different datasets were compared using the Bland-Altman analysis method: the bias and the limits of agreement (LA) were estimated in a head-to-head comparison of the three protocols. RESULTS: In the (Method A-Method C) comparison for LVEF, the bias was 3.8% and the LAs ranged from - 9.3% to 16.8%. The agreement was still lower between Method B and C, whilst only slightly improved when Methods A and B were compared. CONCLUSIONS: The wide amplitude in LA intervals of about 30% indicates that IQ and LEHR GSPECT are not interchangeable. The values obtained with IQ-SPECT should only be used with caution when evaluating the functional state of the heart.