123I-Ioflupane SPECT/CT临床基线显像中视觉与半定量评估的准确性
本研究纳入382例临床不确定帕金森综合征患者,比较有经验读者视觉评估与全自动半定量方法对基线123I-Ioflupane SPECT/CT的一致性,并以运动障碍专家随访诊断为标准评估准确性。视觉评估与半定量方法不一致25例(6.5%,ĸ=0.868),视觉评估准确率87.7%(ĸ=0.75)略高于半定量86.2%(ĸ=0.719,P<0.001),但两种方法诊断性能无显著差异。
要点
- 视觉评估与全自动半定量方法一致性近乎完美(不一致25/382例,6.5%,ĸ=0.868)。
- 以随访临床诊断为标准,视觉评估准确率87.7%(ĸ=0.75)略高于半定量86.2%(ĸ=0.719)。
- 视觉评估与软件半定量的诊断性能无显著差异。
核心结论
- 视觉评估与全自动半定量方法在I-ioflupane判读中一致性近乎完美,但以临床确诊为参考时视觉判读似乎略更准确。
研究设计与样本
- 对382例临床不确定帕金森综合征患者的基线123I-Ioflupane SPECT/CT进行视觉评估与半定量比较,并以运动障碍专家随访诊断作为参考标准。
主要发现
- 视觉评估与半定量方法在382例中不一致25例(6.5%),ĸ=0.868,人读者认为感兴趣区错位是不一致的主要原因。
- 以神经科随访为参考,视觉判读准确率87.7%(ĸ=0.75) vs 半定量86.2%(ĸ=0.719),P<0.001。
- 视觉判读与软件评估的诊断性能无显著差异。
关键数值与推荐
- 视觉评估与半定量不一致25/382例(6.5%),ĸ=0.868。
- 视觉判读准确率87.7%(ĸ=0.75) vs 半定量86.2%(ĸ=0.719),P<0.001。
临床怎么用
- 在临床基线123I-Ioflupane SPECT/CT判读中,有经验读者的视觉评估与全自动半定量一致性高,二者诊断性能无显著差异。
局限性
- 原文未述局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: We aimed to (a) elucidate the concordance of visual assessment of an initial I-ioflupane scan by a human interpreter with comparison to results using a fully automatic semiquantitative method and (b) to assess the accuracy compared to follow-up (f/u) diagnosis established by movement disorder specialists. METHODS: An initial I-ioflupane scan was performed in 382 patients with clinically uncertain Parkinsonian syndrome. An experienced reader performed a visual evaluation of all scans independently. The findings of the visual read were compared with semiquantitative evaluation. In addition, available f/u clinical diagnosis (serving as a reference standard) was compared with results of the human read and the software. RESULTS: When comparing the semiquantitative method with the visual assessment, discordance could be found in 25 (6.5%) of 382 of the cases for the experienced reader (ĸ = 0.868). The human observer indicated region of interest misalignment as the main reason for discordance. With neurology f/u serving as reference, the results of the reader revealed a slightly higher accuracy rate (87.7%, ĸ = 0.75) compared to semiquantification (86.2%, ĸ = 0.719, P < 0.001, respectively). No significant difference in the diagnostic performance of the visual read versus software-based assessment was found. CONCLUSIONS: In comparison with a fully automatic semiquantitative method in I-ioflupane interpretation, human assessment obtained an almost perfect agreement rate. However, compared to clinical established diagnosis serving as a reference, visual read seemed to be slightly more accurate as a solely software-based quantitative assessment.