文献速递心脏核医学

肾移植对左心室功能、心电图及机械同步性的影响:门控心肌灌注显像研究

The effect of renal transplantation on left ventricular function, electrocardiography, and mechanical synchrony by gated myocardial perfusion imaging.
PubMed 文献 · J Nucl Cardiol · 2018-10-22

本研究纳入32例接受肾移植的终末期肾病患者,比较移植前后门控心肌灌注显像测得的LVEF、LVMD指标(相位标准差SD、带宽BW)及心电图指标,并设未接受移植的ESRD对照组。结果显示移植后LVEF(72±10% vs 67±10%,P<0.001)与QTc(425±30 ms vs 447±32 ms,P<0.001)改善,而SD、BW及QRS无变化,对照组上述指标均无变化。

要点

  • 肾移植后LVEF由67±10%升至72±10%(P<0.001),机械同步性指标SD、BW无变化。
  • 肾移植后QTc由447±32 ms缩短至425±30 ms(P<0.001),QRS无变化。
  • 未接受移植的ESRD对照组LVEF、LVMD指标及心电图指标均无变化。

核心结论

  • 肾移植后LVEF和QTc改善,但LVMD指标与QRS未改变,提示ESRD患者的LVMD与电不同步可能不可逆。

研究设计与样本

  • 研究识别肾移植前后均行心肌灌注显像(MPI)的患者,对照组为行两次MPI但未接受移植的ESRD患者,比较LVEF、LVMD指标(相位标准差SD、带宽BW)及心电图指标变化。
  • 研究人群为32例ESRD患者,53%男性,年龄50±11岁,59%为非裔美国人,65%患糖尿病;第二次MPI在肾移植后31个月(13-59个月)进行。

主要发现

  • 移植后LVEF为72±10% vs 67±10%(P<0.001),即移植后LVEF较前升高。
  • 移植后SD为22±15° vs 22±11°(P=0.9)、BW为58±35° vs 57±29°(P=0.9),均无变化。
  • 移植后QTc为425±30 ms vs 447±32 ms(P<0.001),即移植后QTc较前缩短;QRS为90±21 ms vs 90±21 ms(P=0.9),无变化。
  • 对照组上述指标均无变化。

局限性

  • 原文未述局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Depressed left ventricular ejection fraction (LVEF), LV mechanical dyssynchrony (LVMD), and prolonged QTc interval predict poor outcomes in end-stage renal disease (ESRD). Renal transplantation improves mortality in ESRD patients but the effects of transplantation on these indices remain undefined. METHODS: We identified patients with myocardial perfusion imaging (MPI) before and after renal transplantation. A control group consisted of ESRD patients who underwent 2 MPIs but did not receive a transplant. Changes in LVEF, LVMD indices [phase standard deviation (SD) and bandwidth (BW)] by MPI, and electrocardiogram (ECG) indices were determined. RESULTS: The study population consisted of 32 ESRD patients (53% male, 50 ± 11 years, 59% African American, 65% diabetic). The second MPI was performed 31 months (13-59 months) after renal transplantation. LVEF (72 ± 10% vs. 67 ± 10%, P < 0.001) but not SD (22 ± 15° vs. 22 ± 11°, P = 0.9) or BW (58 ± 35° vs. 57 ± 29°, P = 0.9) improved after transplantation. There were no changes in these indices in the control group. QTc (425 ± 30 ms vs. 447 ± 32 ms, P = <0.001) but not QRS (90 ± 21 ms vs. 90 ± 21 ms, P = 0.9) improved significantly after renal transplantation. CONCLUSIONS: LVEF and QTc improved after renal transplantation but LVMD indices and QRS did not change, which suggests that LVMD and electrical dyssynchrony may be irreversible in ESRD.

来源:J Nucl Cardiol,查看原文。版权归原作者所有。

引用

  1. Crosland W, Aggarwal H, Farag A, et al. The effect of renal transplantation on left ventricular function, electrocardiography, and mechanical synchrony by gated myocardial perfusion imaging. J Nucl Cardiol. 2018. PMID: 30350267. doi:10.1007/s12350-018-1411-8

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。