文献速递心脏核医学

简化定量13N-氨水PET心肌血流的临床可行性:与标准隔室模型的比较

Simplified quantification of 13N-ammonia PET myocardial blood flow: A comparative study with the standard compartment model to facilitate clinical use.
PubMed 文献 · J Nucl Cardiol · 2018-10-15

两模型全局和区域MBF及MFR高度相关,RCA区域相关性稍低;健康志愿者组两模型间MFR和静息MBF存在显著差异,并提出了短时简单滞留方案的正常参考值。

要点

  • 简单滞留模型与两隔室模型的全局和区域MBF、MFR高度相关。
  • 健康志愿者组两模型间MFR和静息MBF存在显著差异。
  • 研究提出了13N-氨水短时简单滞留方案的正常参考值。

核心结论

  • 简单滞留模型获得的13N-氨水全局和区域MBF及MFR与两隔室模型高度相关。
  • 健康志愿者组中两模型间MFR和静息MBF存在显著差异,并提出了13N-氨水短时简单滞留方案的正常参考值。

研究设计与样本

  • 简单滞留模型使用前7分钟图像定量MBF,并与两隔室模型比较全局和区域MBF及MFR。

主要发现

  • 两模型全局和区域MBF及MFR高度相关,RCA区域相关性稍低(全局R²:静息MBF=0.79,负荷MBF=0.65,MFR=0.77;区域R²:静息MBF≥0.72,负荷MBF≥0.52,MFR≥0.68)。
  • 健康志愿者组中两模型间MFR(4.04±0.72 vs 3.66±0.48,p=.02)和静息MBF(0.69±0.12 vs 0.78±0.12,p=.02)存在显著差异。

关键数值与推荐

  • 两模型全局R²:静息MBF=0.79,负荷MBF=0.65,MFR=0.77。
  • 两模型区域R²:静息MBF≥0.72,负荷MBF≥0.52,MFR≥0.68。
  • 健康志愿者组两模型MFR:4.04±0.72 vs 3.66±0.48(p=.02)。
  • 健康志愿者组两模型静息MBF:0.69±0.12 vs 0.78±0.12(p=.02)。

临床怎么用

  • 简单滞留模型采用前7分钟图像定量MBF,与两隔室模型结果高度相关,或可促进13N-氨水心脏PET的临床应用。

局限性

  • 原文未述局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Short imaging protocol to quantify myocardial blood flow (MBF) and myocardial flow reserve (MFR) may enhance the clinical application of 13N-ammonia cardiac PET. We assessed the flow quantitation of 13N-ammonia PET implementing simple retention model and two-compartment model. METHODS: Fourteen healthy volunteers (HVT) and twenty-three clinical patients received 13N-ammonia PET/CT. The simple retention model used the first 7-minute image to quantify MBF. Global and regional MBF and MFR of the two models were compared. RESULTS: Global and regional MBF and MFR of these two models were highly correlated with mildly inferior correlation in RCA territory (global R2: rest MBF = 0.79, stress MBF = 0.65, MFR = 0.77; regional R2: rest MBF ≥ 0.72, stress MBF ≥ 0.52, MFR ≥ 0.68). There were significant differences for MFR (4.04 ± 0.72, 3.66 ± 0.48, p = .02) and rest MBF (0.69 ± 0.12, 0.78 ± 0.12, p = .02) between the two models in the HVT group. CONCLUSIONS: 13N-ammonia global and regional MBF and MFR from the simple retention model demonstrate strong correlations with that from the two-compartment model. Significant differences of MFR and rest MBF are noted in the HVT group, with a proposed normal reference value for the 13N-ammonia short simple retention protocol.

来源:J Nucl Cardiol,查看原文。版权归原作者所有。

引用

  1. Chang CY, Hung GU, Hsu B, et al. Simplified quantification of 13N-ammonia PET myocardial blood flow: A comparative study with the standard compartment model to facilitate clinical use. J Nucl Cardiol. 2018. PMID: 30324328. doi:10.1007/s12350-018-1450-1

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。