骨折所致活性增高对68Ga-DOTATATE PET/CT定位TIO责任肿瘤准确性的影响
该研究回顾性分析54例有多发68Ga-DOTATATE PET/CT活性增高灶的疑似肿瘤性骨软化症(TIO)患者,评估骨折部位活性增高是否影响责任肿瘤定位。53例最终确认TIO,52例肿瘤被准确定位;结论认为结合PET活性强度与CT形态学评估时,骨折部位轻度活性不是解读的主要困难因素。
要点
- 54例疑似TIO患者中53例最终确认责任肿瘤,52例被准确定位。
- 解读时同时考虑PET活性强度与CT形态学表现。
- 骨折部位轻度活性增高不显著影响68Ga-DOTATATE PET/CT定位准确性。
核心结论
- 当同时评估PET活性强度与CT形态学表现时,骨折部位轻度活性不是68Ga-DOTATATE PET/CT评估TIO时解读的主要困难因素。
研究设计与样本
- 回顾性分析54例有多发68Ga-DOTATATE PET/CT活性增高灶、临床疑似TIO患者的图像,并将影像分析结果与临床病历记录比较。
主要发现
- 53例患者最终确认责任肿瘤,1例未确认。
- 53例确认TIO的患者中,52例肿瘤被准确定位。
关键数值与推荐
- 解读图像时同时考虑PET活性强度与CT形态学表现。
临床怎么用
- 在评估TIO时,结合PET活性强度与CT形态学表现解读68Ga-DOTATATE PET/CT,有助于区分骨折相关活性与责任肿瘤。
局限性
- 原文未述局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: Ga-DOTATATE PET/CT is currently the most common imaging modality in localizing culprit tumors, which can result in tumor-induced osteomalacia (TIO). Fracture, which is one of the most common consequences of the TIO, can also lead to increased Ga-DOTATATE activity and potentially affect the accuracy of Ga-DOTATATE PET/CT imaging. The aim of this investigation is to evaluate whether the increased Ga-DOTATATE activity at the sites of the fracture will cause interpretation difficulty in the localizing the culprit tumor causing TIO. METHOD: The images of Ga-DOTATATE PET/CT scan from a total of 54 patients who had multiple foci of increased Ga-DOTATATE PET/CT on PET/CT were retrospectively analyzed. Not only was the intensity of the activity on PET but also the appearance of the activity on CT taken into consideration when the interpretation of the images occurred. The results from imaging analysis were compared with the clinical chart record. All patients had tentative clinical diagnosis of TIO. RESULTS: The causative tumors in 53 patients were eventually identified. In 1 patient, the causative tumor was not identified. Among the 53 patients with confirmed TIO, 52 tumors were accurately localized. CONCLUSIONS: Mild activity at the sites of fracture is not a major challenging factor in the interpretation of Ga-DOTATATE PET/CT in the evaluation of TIO when both intensity on PET and morphology on CT were assessed.
引用
- Ding J, Hu G, Wang L, et al. Increased Activity Due to Fractures Does Not Significantly Affect the Accuracy of 68Ga-DOTATATE PET/CT in the Detection of Culprit Tumor in the Evaluation of Tumor-Induced Osteomalacia. Clin Nucl Med. 2018. PMID: 30273206. doi:10.1097/RLU.0000000000002290
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。