文献速递心脏核医学

相位分析在双嘧达莫铊-201门控心肌灌注显像诊断冠心病中的临床价值

The clinical usefulness of phase analysis in detecting coronary artery disease using dipyridamole thallium-201-gated myocardial perfusion imaging with a cadmium-zinc-telluride camera.
PubMed 文献 · J Nucl Cardiol · 2018-08-31

回顾性分析476例无已知冠心病患者,均接受双嘧达莫铊-201门控心肌灌注显像及6个月内冠状动脉造影。灌注异常是检出冠心病的最佳诊断工具;负荷后冠心病组左室同步性较非冠心病组减低,但未见显著不同步。在≥50%狭窄冠心病患者中,相位分析对诊断冠心病的附加价值可能有限。

要点

  • 灌注异常是检出冠心病的最佳诊断工具。
  • 负荷后冠心病组左室同步性较非冠心病组减低,但无显著不同步。
  • 在≥50%狭窄冠心病患者中,相位分析辅助诊断价值可能有限。

核心结论

  • 在双嘧达莫负荷铊-201门控SPECT中,将相位分析用于辅助诊断≥50%狭窄的冠心病可能价值有限。

研究设计与样本

  • 回顾性分析476例无已知冠心病患者,均接受双嘧达莫铊-201心肌灌注显像及6个月内冠状动脉造影。

主要发现

  • 灌注异常是检出冠心病的最佳诊断工具。
  • 负荷后冠心病组左室同步性较非冠心病组减低,但未见显著不同步。

关键数值与推荐

  • 评估的相位参数包括相位标准差、相位直方图带宽、相位偏度和相位峰度,以及心肌灌注和心肌顿抑。
  • 冠心病定义为冠状动脉造影显示≥50%狭窄。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Previous studies have demonstrated left ventricular mechanical dyssynchrony (LVMD) in patients with severe coronary artery disease (CAD) with ≥ 70% stenosis. The aim of this study was to evaluate the clinical usefulness of stress/rest LVMD in the diagnosis of CAD with ≥ 50% stenosis using dipyridamole thallium-201 (Tl-201) myocardial perfusion imaging (MPI) with a cadmium-zinc-telluride camera. METHODS AND RESULTS: A total of 476 patients without known CAD who underwent dipyridamole Tl-201 MPI and coronary angiography within 6 months were retrospectively reviewed. LVMD parameters including phase standard deviation and phase histogram bandwidth, phase skewness and phase kurtosis, as well as myocardial perfusion and myocardial stunning were assessed in post-stress and rest MPI. Relationships between the presence of CAD on coronary angiography and single photon emission computerized tomography (SPECT) parameters were evaluated. The presence of perfusion abnormalities was the best diagnostic tool in detecting CAD. Although less left ventricular synchrony was observed post-stress in the CAD group compared to the non-CAD group, no significant dyssynchrony was noted. CONCLUSIONS: The addition of phase analysis to help diagnose CAD in Tl-201-gated SPECT with dipyridamole stress may have limited value in patients with CAD with ≥ 50% stenosis.

来源:J Nucl Cardiol,查看原文。版权归原作者所有。

引用

  1. Lin WL, Wang SY, Shiau YC, et al. The clinical usefulness of phase analysis in detecting coronary artery disease using dipyridamole thallium-201-gated myocardial perfusion imaging with a cadmium-zinc-telluride camera. J Nucl Cardiol. 2018. PMID: 30171522. doi:10.1007/s12350-018-1417-2

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。