文献速递心脏核医学

首次通过门控15O-水PET评估双心室容积与功能的可行性

Feasibility of biventricular volume and function assessment using first-pass gated 15O-water PET.
PubMed 文献 · EJNMMI Res · 2018-09-17

本研究为前瞻性研究,纳入19例接受15O-水PET心肌灌注储备评估的患者,探讨首次通过门控15O-水PET评估左右心室容积与功能的可行性。结果显示静息与负荷PET间一致性优良,左心室参数与99mTc-甲氧基异丁基异腈门控心肌SPECT相关性高,PET仅轻微高估左心室收缩末期容积并低估射血分数。

要点

  • 首次通过门控15O-水PET可行双心室容积与功能评估。
  • 静息与负荷PET间双心室容积和功能一致性优良。
  • 左心室参数与门控心肌SPECT相关性高,PET轻微高估ESV、低估EF。

核心结论

  • 首次通过门控15O-水PET可实现双心室容积与功能评估,左心室参数与门控心肌SPECT相关性良好。

研究设计与样本

  • 前瞻性研究,纳入19例接受15O-水PET心肌灌注储备评估的患者,于静息和瑞加诺生负荷后采集PET数据,重建门控首次通过图像,使用TomPool软件后处理,半自动4D浸没算法分割左右心室。

主要发现

  • 静息与负荷PET间,双心室EDV和ESV的Lin一致性系数约0.85-0.90,SV约0.80,EF约0.75。
  • 左心室EDV与心肌SPECT的Pearson R=0.89(p<0.001),ESV的R=0.87(p<0.001),SV的R=0.67(p<0.001),EF的R=0.67(p<0.001)。
  • PET显示左心室ESV轻微高估(+4 mL,p=0.03)和EF轻微低估(-4%,p=0.01)。

关键数值与推荐

  • 左心室容积采用基于计数的模型和最大活度的固定阈值30%计算。
  • 右心室容积采用几何模型和可调阈值计算,阈值设定为使左右心室每搏输出量匹配。
  • 射血曲线采用可变形参考曲线模型拟合。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: We investigated the feasibility of left ventricular (LV) and right ventricular (RV) volume and function estimation using a first-pass gated 15O-water PET. This prospective study included 19 patients addressed for myocardial perfusion reserve assessment using 15O-water PET. PET data were acquired at rest and after regadenoson stress, and gated first-pass images were reconstructed over the time range corresponding to tracer first-pass through the cardiac cavities and post-processed using TomPool software; LV and RV were segmented using a semi-automated 4D immersion algorithm. LV volumes were computed using a count-based model and a fixed threshold at 30% of the maximal activity. RV volumes were computed using a geometrical model and an adjustable threshold that was set so as to fit LV and RV stroke volumes. Ejection curves were fitted using a deformable reference curve model. LV results were compared to those obtained using 99mTc-sestamibi gated myocardial SPECT in terms of end-diastolic volume (EDV), end-systolic volume (ESV), stroke volume (SV), and ejection fraction (EF). RESULTS: There was an excellent concordance between rest and stress PET in terms of EDV and ESV (Lin's coefficient ~ 0.85-0.90), SV (~ 0.80), and EF (~ 0.75) for both ventricles. Correlation with myocardial SPECT was high for LV EDV (Pearson's R = 0.89, p < 0.001) and ESV (R = 0.87, p < 0.001) and satisfying for LV SV (R = 0.67, p < 0.001) and EF (R = 0.67, p < 0.001). Minimal LV ESV overestimation (+ 4 mL, p = 0.03) and EF underestimation (- 4%, p = 0.01) were observed using PET. CONCLUSIONS: Biventricular volume and function assessment are achievable using the first-pass PET, and LV parameters correlate well with those derived from gated myocardial SPECT.

来源:EJNMMI Res,查看原文。版权归原作者所有。

引用

  1. Ben Bouallègue F, Mariano-Goulart D, Agostini D, et al. Feasibility of biventricular volume and function assessment using first-pass gated 15O-water PET. EJNMMI Res. 2018. PMID: 30225682. doi:10.1186/s13550-018-0445-x

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。