PET显像对起搏器或除颤器感染导线拔除候选者死亡风险分层的贡献:前瞻性单中心研究
该前瞻性单中心观察性研究纳入105例确诊心脏植入式电子装置感染(CIEDI)并接受经静脉导线拔除(TLE)的连续患者,术前均行18F-FDG PET/CT。中位随访25.0±9.0个月,31例(29.5%)死亡;CIED囊袋受累者生存更好(HR 0.493,95%CI 0.240-0.984;p=0.048)。整合PET/CT数据后,无明确/隐藏囊袋受累和GFR<60 ml/min是长期死亡的独立预测因素。
要点
- 105例CIEDI患者术前18F-FDG PET/CT,56例囊袋受累,40例全身受累,9例PET阴性。
- 随访25.0±9.0个月,31例(29.5%)死亡;囊袋受累者生存更好(HR 0.493,95%CI 0.240-0.984;p=0.048)。
- 整合PET/CT后,无明确/隐藏囊袋受累和GFR<60 ml/min是长期死亡的独立预测因素。
核心结论
- CIEDI且冷闭合囊袋(即CIED囊袋无皮肤侵蚀/穿孔且18F-FDG PET/CT无摄取增高)的患者长期生存更差。
- 通过提高对CIED相关感染性心内膜炎(CIEDIE)和隐藏囊袋受累的识别,系统性地在TLE前采用18F-FDG PET/CT可使患者管理获益。
研究设计与样本
- 前瞻性、单中心观察性研究,连续纳入因诊断CIEDI而成为TLE候选者的患者,所有患者TLE前均行18F-FDG PET/CT。
- 共纳入105例确诊CIEDI的连续患者。
主要发现
- 18F-FDG摄取增高局限于CIED囊袋者56例,全身受累者40例。
- 9例PET阴性患者接受延长抗菌治疗(22.5±14.0天 vs. 8.6±13.0天;p=0.005)。
- 将18F-FDG PET/CT纳入改良Duke标准导致23.8%的患者重新分类。
- 平均随访25.0±9.0个月后,31例(29.5%)死亡。
- CIED囊袋受累患者生存更好,独立于全身受累的有无(HR 0.493,95%CI 0.240-0.984;p=0.048)。
关键数值与推荐
- CIED囊袋受累 vs. 无囊袋受累:HR 0.493(95%CI 0.240-0.984;p=0.048),囊袋受累者生存更好。
- PET阴性者抗菌治疗22.5±14.0天 vs. PET阳性者8.6±13.0天(p=0.005)。
- 整合PET/CT后,无明确/隐藏囊袋受累和GFR<60 ml/min是长期死亡的独立预测因素。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: 18F-FDG PET/CT is an emerging technique for diagnosis of cardiac implantable electronic devices infection (CIEDI). Despite the improvements in transvenous lead extraction (TLE), long-term survival in patients with CIEDI is poor. The aim of the present study was to evaluate whether the extension of CIEDI at 18F-FDG PET/CT can improve prediction of survival after TLE. METHODS: Prospective, monocentric observational study enrolling consecutive candidates to TLE for a diagnosis of CIEDI. 18F-FDG PET/CT was performed in all patients prior TLE. RESULTS: There were 105 consecutive patients with confirmed CIEDI enrolled. An increased 18F-FDG uptake was limited to cardiac implantable electrical device (CIED) pocket in 56 patients, 40 patients had a systemic involvement. We had nine negative PET in patients undergoing prolonged antimicrobial therapy (22.5 ± 14.0 days vs. 8.6 ± 13.0 days; p = 0.005). Implementation of 18F-FDG PET/CT in modified Duke Criteria lead to reclassification of 23.8% of the patients. After a mean follow-up of 25.0 ± 9.0 months, 31 patients died (29.5%). Patients with CIED pocket involvement at 18F-FDG PET/CT presented a better survival independently of presence/absence of systemic involvement (HR 0.493, 95%CI 0.240-0.984; p = 0.048). After integration of 18F-FDG PET/CT data, absence of overt/hidden pocket involvement in CIEDI and a (glomerular filtration rate) GFR < 60 ml/min were the only independent predictors of mortality at long term. CONCLUSIONS: Patient with CIEDI and a Cold Closed Pocket (i.e., a CIED pocket without skin erosion/perforation nor increased capitation at 18F-FDG PET/CT) present worse long-term survival. Patient management can benefit by systematic adoption of pre-TLE 18F-FDG PET/CT through improved identification of CIED related endocarditis (CIEDIE) and hidden involvement of CIED pocket.
引用
- Diemberger I, Bonfiglioli R, Martignani C, et al. Contribution of PET imaging to mortality risk stratification in candidates to lead extraction for pacemaker or defibrillator infection: a prospective single center study. Eur J Nucl Med Mol Imaging. 2018. PMID: 30196365. doi:10.1007/s00259-018-4142-9
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。