文献速递心脏核医学肿瘤 PET/CT放射性药物与辐射防护

PET显像对起搏器或除颤器感染导线拔除候选者死亡风险分层的贡献:前瞻性单中心研究

Contribution of PET imaging to mortality risk stratification in candidates to lead extraction for pacemaker or defibrillator infection: a prospective single center study.
PubMed 文献 · Eur J Nucl Med Mol Imaging · 2018-09-08

该前瞻性单中心观察性研究纳入105例确诊心脏植入式电子装置感染(CIEDI)并接受经静脉导线拔除(TLE)的连续患者,术前均行18F-FDG PET/CT。中位随访25.0±9.0个月,31例(29.5%)死亡;CIED囊袋受累者生存更好(HR 0.493,95%CI 0.240-0.984;p=0.048)。整合PET/CT数据后,无明确/隐藏囊袋受累和GFR<60 ml/min是长期死亡的独立预测因素。

要点

  • 105例CIEDI患者术前18F-FDG PET/CT,56例囊袋受累,40例全身受累,9例PET阴性。
  • 随访25.0±9.0个月,31例(29.5%)死亡;囊袋受累者生存更好(HR 0.493,95%CI 0.240-0.984;p=0.048)。
  • 整合PET/CT后,无明确/隐藏囊袋受累和GFR<60 ml/min是长期死亡的独立预测因素。

核心结论

  • CIEDI且冷闭合囊袋(即CIED囊袋无皮肤侵蚀/穿孔且18F-FDG PET/CT无摄取增高)的患者长期生存更差。
  • 通过提高对CIED相关感染性心内膜炎(CIEDIE)和隐藏囊袋受累的识别,系统性地在TLE前采用18F-FDG PET/CT可使患者管理获益。

研究设计与样本

  • 前瞻性、单中心观察性研究,连续纳入因诊断CIEDI而成为TLE候选者的患者,所有患者TLE前均行18F-FDG PET/CT。
  • 共纳入105例确诊CIEDI的连续患者。

主要发现

  • 18F-FDG摄取增高局限于CIED囊袋者56例,全身受累者40例。
  • 9例PET阴性患者接受延长抗菌治疗(22.5±14.0天 vs. 8.6±13.0天;p=0.005)。
  • 将18F-FDG PET/CT纳入改良Duke标准导致23.8%的患者重新分类。
  • 平均随访25.0±9.0个月后,31例(29.5%)死亡。
  • CIED囊袋受累患者生存更好,独立于全身受累的有无(HR 0.493,95%CI 0.240-0.984;p=0.048)。

关键数值与推荐

  • CIED囊袋受累 vs. 无囊袋受累:HR 0.493(95%CI 0.240-0.984;p=0.048),囊袋受累者生存更好。
  • PET阴性者抗菌治疗22.5±14.0天 vs. PET阳性者8.6±13.0天(p=0.005)。
  • 整合PET/CT后,无明确/隐藏囊袋受累和GFR<60 ml/min是长期死亡的独立预测因素。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: 18F-FDG PET/CT is an emerging technique for diagnosis of cardiac implantable electronic devices infection (CIEDI). Despite the improvements in transvenous lead extraction (TLE), long-term survival in patients with CIEDI is poor. The aim of the present study was to evaluate whether the extension of CIEDI at 18F-FDG PET/CT can improve prediction of survival after TLE. METHODS: Prospective, monocentric observational study enrolling consecutive candidates to TLE for a diagnosis of CIEDI. 18F-FDG PET/CT was performed in all patients prior TLE. RESULTS: There were 105 consecutive patients with confirmed CIEDI enrolled. An increased 18F-FDG uptake was limited to cardiac implantable electrical device (CIED) pocket in 56 patients, 40 patients had a systemic involvement. We had nine negative PET in patients undergoing prolonged antimicrobial therapy (22.5 ± 14.0 days vs. 8.6 ± 13.0 days; p = 0.005). Implementation of 18F-FDG PET/CT in modified Duke Criteria lead to reclassification of 23.8% of the patients. After a mean follow-up of 25.0 ± 9.0 months, 31 patients died (29.5%). Patients with CIED pocket involvement at 18F-FDG PET/CT presented a better survival independently of presence/absence of systemic involvement (HR 0.493, 95%CI 0.240-0.984; p = 0.048). After integration of 18F-FDG PET/CT data, absence of overt/hidden pocket involvement in CIEDI and a (glomerular filtration rate) GFR < 60 ml/min were the only independent predictors of mortality at long term. CONCLUSIONS: Patient with CIEDI and a Cold Closed Pocket (i.e., a CIED pocket without skin erosion/perforation nor increased capitation at 18F-FDG PET/CT) present worse long-term survival. Patient management can benefit by systematic adoption of pre-TLE 18F-FDG PET/CT through improved identification of CIED related endocarditis (CIEDIE) and hidden involvement of CIED pocket.

来源:Eur J Nucl Med Mol Imaging,查看原文。版权归原作者所有。

引用

  1. Diemberger I, Bonfiglioli R, Martignani C, et al. Contribution of PET imaging to mortality risk stratification in candidates to lead extraction for pacemaker or defibrillator infection: a prospective single center study. Eur J Nucl Med Mol Imaging. 2018. PMID: 30196365. doi:10.1007/s00259-018-4142-9

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。