两相采集与灰质勾画改善β-淀粉样蛋白PET可重复性
本研究在121例轻度认知障碍患者中行两相氟替美他醇PET,比较标准视觉判读与利用灌注相灰质边缘的新方法。新方法在五点 amyloid 阳性评分、二分类及医师主观信心上均显示更高的阅片者间一致性,且易于临床实施。
要点
- GM-EDGE法五点评分加权Cohen kappa中位数0.80,STD法为0.70。
- GM-EDGE法二分类Fleiss kappa 0.93,STD法为0.82。
- GM-EDGE法使四位医师阅片主观信心显著提高(p<0.010)。
核心结论
- 新引入的GM-EDGE方法与医师间一致性显著提高及阅片主观信心更高相关,且易于在临床实践中实施,尤其当临床利用灌注相时。
研究设计与样本
- 对121例轻度认知障碍患者行两相氟替美他醇PET,由五名核医学医师盲法独立先以STD法、后以GM-EDGE法评估所有晚期相扫描。
主要发现
- 五点amyloid阳性评分的加权Cohen kappa:STD法范围0.63至0.73(中位数0.70),GM-EDGE法范围0.76至0.89(中位数0.80)。
- ICC:STD法0.84(95%CI 0.79-0.88),GM-EDGE法0.91(95%CI 0.89-0.94)。
- 二分类非加权Cohen kappa:STD法范围0.73至0.93(中位数0.82),GM-EDGE法范围0.90至0.97(中位数0.93)。
- Fleiss kappa:STD法0.82(95%CI 0.77-0.88),GM-EDGE法0.93(95%CI 0.87-0.99)。
- GM-EDGE法使四位医师阅片主观信心显著提高(p<0.010);五名医师二分类完全一致的比例STD法为80.8%,GM-EDGE法为91.6%(p=0.016)。
临床怎么用
- 作者认为该新方法易于在临床实践中实施,尤其当临床利用灌注相时。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: We investigated whether the reproducibility of standard visual reporting (STD method) in flutemetamol (FMM) PET can be improved using a newly introduced method that uses grey matter edges derived from the perfusion phase (GM-EDGE method). METHODS: Two-phase FMM PET was performed in 121 patients with mild cognitive impairment. Five nuclear medicine physicians blindly and independently evaluated all late-phase scans, initially employing the STD method and later the GM-EDGE method. A five-point scale was used to express the degree of amyloid positivity, and a binary classification (positive/negative) was used in combination with subjective confidence (five-point scale). Multirater Fleiss' kappa, intraclass correlation coefficient (ICC) and inter-rater reliability (Cohen's kappa) were determined for the STD and GM-EDGE methods. RESULTS: The weighted Cohen's kappa values for the five-point measure of amyloid positivity ranged from 0.63 to 0.73 (median 0.70) for the STD method and from 0.76 to 0.89 (median 0.80) for the GM-EDGE method (ICC 0.84, 95% CI 0.79-0.88, for the STD method; 0.91, 95% CI 0.89-0.94, for the GM-EDGE method). The nonweighted Cohen's kappa value for the binary classification ranged from 0.73 to 0.93 (median 0.82) for the STD method and 0.90 to 0.97 (median 0.93) for the GM-EDGE method (Fleiss' kappa 0.82, 95% CI 0.77-0.88, for the STD method; 0.93, 95% CI 0.87-0.99, for the GM-EDGE method). The GM-EDGE method resulted in significantly greater subjective confidence in the readings of four physicians (p < 0.010). The binary classification was concordant among all five physicians in 80.8% of the scans using the STD method and in 91.6% of the scans using the GM-EDGE method (p = 0.016). CONCLUSION: The newly introduced GM-EDGE method was associated with significantly higher inter-rater agreement among physicians and higher subjective confidence in the reading. The method is easy to implement in clinical practice, especially when the perfusion phase is utilized clinically.
引用
- Belohlavek O, Jaruskova M, Skopalova M, et al. Improved beta-amyloid PET reproducibility using two-phase acquisition and grey matter delineation. Eur J Nucl Med Mol Imaging. 2018. PMID: 30159586. doi:10.1007/s00259-018-4140-y
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。