文献速递肿瘤 PET/CT

原发肿瘤影像组学提高18F-FDG PET检测子宫内膜癌淋巴结转移的敏感性

Radiomics of the primary tumour as a tool to improve 18F-FDG-PET sensitivity in detecting nodal metastases in endometrial cancer.
PubMed 文献 · EJNMMI Res · 2018-08-22

本研究回顾性纳入115例经组织学证实为子宫内膜癌、术前接受18F-FDG PET/CT的女性,在肿瘤轮廓内计算SUV、MTV、TLG、几何形状、直方图及纹理特征。在86例患者(DB1)中开发神经网络多变量模型,并在29例患者(DB2)中验证;原发肿瘤的GLSZM ZP单独预测淋巴结转移优于其他特征或多变量模型,DB1敏感性和特异性为75%和81%,DB2为89%和80%。视觉检测与GLSZM ZP联合框架在DB1的敏感性和特异性为94%和67%,DB2为89%和75%;作者认为该影像特征可考虑用于更好的患者分层以选择治疗,结果需在更大队列研究中确认。

要点

  • 原发肿瘤GLSZM ZP预测淋巴结转移:DB1敏感性75%、特异性81%,DB2敏感性89%、特异性80%。
  • 视觉检测联合GLSZM ZP:DB1敏感性94%、特异性67%,DB2敏感性89%、特异性75%。
  • 作者认为原发肿瘤影像特征可考虑用于更好的患者分层以选择治疗。

核心结论

  • 原发肿瘤影像特征的计算提高了18F-FDG PET对淋巴结分期的检测敏感性,可考虑用于更好的患者分层以选择治疗。
  • 结果需在更大队列研究中确认。

研究设计与样本

  • 回顾性纳入115例经组织学证实为子宫内膜癌、术前接受18F-FDG PET/CT的女性。
  • 在肿瘤轮廓内计算SUV、MTV、TLG、几何形状、直方图和纹理特征。
  • 在86例患者(DB1)中通过Mann-Whitney检验计算与淋巴结转移的单变量关联,并开发神经网络多变量模型。
  • 单变量和多变量模型在20个训练会话上以留一法评估,并在29例患者(DB2)中评估。
  • 评估结合淋巴结转移视觉检测结果与影像组学分析的统一框架。

主要发现

  • 淋巴结视觉检测的敏感性和特异性在DB1为50%和99%,在DB2为33%和95%。
  • 原发肿瘤的单一异质性特征GLSZM ZP预测淋巴结转移优于任何其他特征或多变量模型,DB1敏感性和特异性为75%和81%,DB2为89%和80%。
  • 有淋巴结转移的肿瘤通常以较低的GLSZM ZP值为特征,即高摄取和低摄取区域共存。
  • 视觉检测与GLSZM ZP值联合的统一框架在DB1敏感性和特异性为94%和67%,在DB2为89%和75%。

临床怎么用

  • 作者认为原发肿瘤影像特征可考虑用于更好的患者分层以选择治疗。

局限性

  • 结果需在更大队列研究中确认。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: A radiomic approach was applied in 18F-FDG PET endometrial cancer, to investigate if imaging features computed on the primary tumour could improve sensitivity in nodal metastases detection. One hundred fifteen women with histologically proven endometrial cancer who underwent preoperative 18F-FDG PET/CT were retrospectively considered. SUV, MTV, TLG, geometrical shape, histograms and texture features were computed inside tumour contours. On a first group of 86 patients (DB1), univariate association with LN metastases was computed by Mann-Whitney test and a neural network multivariate model was developed. Univariate and multivariate models were assessed with leave one out on 20 training sessions and on a second group of 29 patients (DB2). A unified framework combining LN metastases visual detection results and radiomic analysis was also assessed. RESULTS: Sensitivity and specificity of LN visual detection were 50% and 99% on DB1 and 33% and 95% on DB2, respectively. A unique heterogeneity feature computed on the primary tumour (the zone percentage of the grey level size zone matrix, GLSZM ZP) was able to predict LN metastases better than any other feature or multivariate model (sensitivity and specificity of 75% and 81% on DB1 and of 89% and 80% on DB2). Tumours with LN metastases are in fact generally characterized by a lower GLSZM ZP value, i.e. by the co-presence of high-uptake and low-uptake areas. The combination of visual detection and GLSZM ZP values in a unified framework obtained sensitivity and specificity of 94% and 67% on DB1 and of 89% and 75% on DB2, respectively. CONCLUSIONS: The computation of imaging features on the primary tumour increases nodal staging detection sensitivity in 18F-FDG PET and can be considered for a better patient stratification for treatment selection. Results need a confirmation on larger cohort studies.

来源:EJNMMI Res,查看原文。版权归原作者所有。

引用

  1. De Bernardi E, Buda A, Guerra L, et al. Radiomics of the primary tumour as a tool to improve 18F-FDG-PET sensitivity in detecting nodal metastases in endometrial cancer. EJNMMI Res. 2018. PMID: 30136163. doi:10.1186/s13550-018-0441-1

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。