常规18F-FDG PET/CT二分法评估颅动脉炎症诊断巨细胞动脉炎准确度高:病例对照研究
本研究为回顾性病例对照研究,纳入44例新发巨细胞动脉炎(GCA)患者和44例年龄性别匹配的黑色素瘤术后对照,评估常规18F-FDG PET/CT颅动脉摄取诊断GCA的准确性。仅颞动脉和/或上颌动脉摄取时敏感度64%、特异度100%,纳入椎动脉后敏感度升至82%、特异度保持100%,读者间一致率91%、Fleiss kappa 0.82。作者认为常规18F-FDG PET/CT是诊断未经糖皮质激素治疗GCA患者颅动脉炎的准确可靠工具,高特异度提示颅动脉FDG摄取阳性者可省略颞动脉活检。
要点
- 仅颞动脉和/或上颌动脉FDG摄取诊断GCA敏感度64%、特异度100%。
- 纳入椎动脉后敏感度升至82%、特异度保持100%。
- 读者间一致率91%、Fleiss kappa 0.82,可靠性高。
核心结论
- 常规18F-FDG PET/CT是诊断未经糖皮质激素治疗的GCA患者颅动脉炎的准确可靠工具。
- 高诊断特异度提示颅动脉18F-FDG摄取阳性的患者可省略颞动脉活检。
- 对疑似血管炎患者行18F-FDG PET/CT时应始终包括头颈部。
研究设计与样本
- 回顾性病例对照研究,参考诊断采用1990年ACR的GCA标准。
- 所有患者均为新发GCA,常规18F-FDG PET/CT在糖皮质激素治疗前进行。
- 对照组为年龄和性别匹配的黑色素瘤(MM)术后>6个月行监测PET/CT的患者。
- PET图像均匀裁剪至仅含头颈部,由4名对参考诊断设盲的核医学医师随机顺序评估。
- 共纳入44例患者和44例对照,两组平均年龄均为69岁(p=0.45),各有25/44为女性。
主要发现
- 41例GCA患者中35例颞动脉活检(TAB)阳性。
- 仅颞动脉和/或上颌动脉FDG摄取时,诊断敏感度64%、特异度100%。
- 纳入椎动脉后,敏感度增至82%、特异度保持100%。
- 基于颅动脉的PET诊断读者间一致率为91%,Fleiss kappa为0.82。
关键数值与推荐
- 参考诊断为符合1990年ACR的GCA标准。
- 仅颞动脉和/或上颌动脉FDG摄取:敏感度64%、特异度100%。
- 颞动脉、上颌动脉和椎动脉FDG摄取:敏感度82%、特异度100%。
- 读者间一致率91%,Fleiss kappa 0.82。
临床怎么用
- 作者认为常规18F-FDG PET/CT可用于诊断未经糖皮质激素治疗的GCA患者的颅动脉炎。
- 作者认为颅动脉18F-FDG摄取阳性的患者可省略颞动脉活检。
- 作者认为对疑似血管炎患者行18F-FDG PET/CT时应始终包括头颈部。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: To estimate the diagnostic accuracy of conventional 18F-FDG PET/CT of cranial arteries in the diagnosis of giant cell arteritis (GCA). METHODS: The study was a retrospective case-control study. The reference diagnosis was fulfillment of the 1990 ACR criteria for GCA. All patients had new-onset GCA. Conventional 18F-FDG PET/CT was performed before glucocorticoid treatment. Controls were age- and sex-matched patients with a previous history of malignant melanoma (MM) undergoing surveillance PET/CT >6 months after MM resection. PET images were evenly cropped to include only head and neck and were assessed in random order by four nuclear medicine physicians blinded to reference diagnosis. Temporal (TA), maxillary (MA) and vertebral (VA) arteries were visually rated for 18F-FDG uptake. Interreader agreement was evaluated by Fleiss kappa. RESULTS: A total of 44 patients and 44 controls were identified. In both groups, the mean age was 69 years (p = 0.45) and 25/44 were women. 35/41 GCA patients were temporal artery biopsy positive (TAB). Considering only FDG uptake in TA and/or MA, diagnostic sensitivity and specificity was 64 and 100%. Including VA, sensitivity increased to 82% and specificity remained 100%. Interreader agreement was 91% and Fleiss kappa 0.82 for the PET diagnosis based on the cranial arteries. CONCLUSION: Conventional 18F-FDG PET/CT is an accurate and reliable tool to diagnose cranial arteritis in glucocorticoid-naïve GCA patients. The high diagnostic specificity suggests that TAB can be omitted in patients with 18F-FDG uptake in cranial arteries. 18F-FDG PET/CT performed in patients with suspected vasculitis should always include the head and neck.
引用
- Nielsen BD, Hansen IT, Kramer S, et al. Simple dichotomous assessment of cranial artery inflammation by conventional 18F-FDG PET/CT shows high accuracy for the diagnosis of giant cell arteritis: a case-control study. Eur J Nucl Med Mol Imaging. 2018. PMID: 30066157. doi:10.1007/s00259-018-4106-0
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。