文献速递肿瘤 PET/CT放射性药物与辐射防护

谷氨酸钠降低临床前前列腺癌模型中唾液腺与肾脏的68Ga-PSMA-11摄取

Monosodium Glutamate Reduces 68Ga-PSMA-11 Uptake in Salivary Glands and Kidneys in a Preclinical Prostate Cancer Model.
PubMed 文献 · J Nucl Med · 2018-08-10

在LNCaP荷瘤小鼠中,腹腔注射谷氨酸钠(MSG)15分钟后静脉给予68Ga-PSMA-11,1小时后行PET/CT与生物分布研究。MSG以剂量依赖方式降低唾液腺和肾脏摄取,而肿瘤摄取在各组间无统计学差异。

要点

  • 657 mg/kg MSG组肾脏摄取85.8±24.2 %ID,显著低于PBS组182±33.5 %ID(P<0.001)。
  • 657与329 mg/kg组唾液腺摄取低于PBS组(P<0.01),肿瘤摄取组间无统计学差异。
  • MSG降低68Ga-PSMA-11唾液腺与肾脏摄取呈剂量依赖,肿瘤摄取未受影响。

核心结论

  • MSG以剂量依赖方式降低68Ga-PSMA-11在唾液腺和肾脏的摄取,而肿瘤摄取未受影响。

研究设计与样本

  • 在LNCaP荷瘤小鼠中腹腔注射MSG(657、329或164 mg/kg)或磷酸盐缓冲液(PBS),15分钟后静脉给予68Ga-PSMA-11,给药后1小时行PET/CT显像与生物分布研究。

主要发现

  • 肿瘤摄取(%ID)在657 mg/kg组为8.42±1.40、329 mg/kg组为7.19±0.86、164 mg/kg组为8.20±2.44、PBS组为8.67±1.97,组间无统计学差异。
  • 肾脏摄取在657 mg/kg组为85.8±24.2 %ID,低于329 mg/kg组159±26.2 %ID、164 mg/kg组211±27.4 %ID和PBS组182±33.5 %ID(P<0.001)。
  • 唾液腺摄取在657 mg/kg组为3.72±2.12 %ID、329 mg/kg组为5.74±0.62 %ID,低于PBS组10.04±2.52 %ID(P<0.01)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

We evaluated the ability of monosodium glutamate (MSG) to reduce salivary and kidney uptake of a prostate-specific membrane antigen (PSMA) radioligand without affecting tumor uptake. Methods: LNCaP tumor-bearing mice were intraperitoneally injected with MSG (657, 329, or 164 mg/kg) or phosphate-buffered saline (PBS). Fifteen minutes later, the mice were intravenously administered 68Ga-PSMA-11. PET/CT imaging and biodistribution studies were performed 1 h after administration. Results: Tumor uptake (percentage injected dose per gram [%ID]) was not statistically different between groups, at 8.42 ± 1.40 %ID in the 657 mg/kg group, 7.19 ± 0.86 %ID in the 329 mg/kg group, 8.20 ± 2.44 %ID in the 164 mg/kg group, and 8.67 ± 1.97 %ID in the PBS group. Kidney uptake was significantly lower in the 657 mg/kg group (85.8 ± 24.2 %ID) than in the 329 mg/kg (159 ± 26.2 %ID), 164 mg/kg (211 ± 27.4 %ID), and PBS groups (182 ± 33.5 %ID) (P < 0.001). Salivary gland uptake was lower in the 657 mg/kg (3.72 ± 2.12 %ID) and 329 mg/kg (5.74 ± 0.62 %ID) groups than in the PBS group (10.04 ± 2.52 %ID) (P < 0.01). Conclusion: MSG decreased salivary and kidney uptake of 68Ga-PSMA-11 in a dose-dependent manner, whereas tumor uptake was unaffected.

来源:J Nucl Med,查看原文。版权归原作者所有。

引用

  1. Rousseau E, Lau J, Kuo HT, et al. Monosodium Glutamate Reduces 68Ga-PSMA-11 Uptake in Salivary Glands and Kidneys in a Preclinical Prostate Cancer Model. J Nucl Med. 2018. PMID: 30097503. doi:10.2967/jnumed.118.215350

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。