F-18 FDG PET评估大血管炎疾病活动性的系统评价与Meta分析
该Meta分析纳入9项研究共298例患者的439幅PET图像,评估F-18 FDG PET或PET/CT检测大血管炎活动性的效能。汇总敏感度为0.88(95%CI 0.79-0.93),汇总特异度为0.81(95%CI 0.64-0.91),汇总诊断比值比为30(95%CI 8-107),sROC曲线下面积为0.91(95%CI 0.89-0.94)。作者认为F-18 FDG PET对检测大血管炎活动性疾病状态有良好效能,建议引入并验证结合PET的修订版疾病活动性评估标准,并需进一步研究基于PET的治疗能否改善结局。
要点
- F-18 FDG PET检测大血管炎活动性的汇总敏感度为0.88(95%CI 0.79-0.93),汇总特异度为0.81(95%CI 0.64-0.91)。
- 汇总诊断比值比为30(95%CI 8-107),sROC曲线下面积为0.91(95%CI 0.89-0.94)。
- 作者建议引入并验证结合F-18 FDG PET或PET/CT的修订版疾病活动性评估标准。
核心结论
- F-18 FDG PET对检测大血管炎患者的活动性疾病状态有良好效能。
- 作者建议引入并验证结合F-18 FDG PET或PET/CT的修订版疾病活动性评估标准。
- 作者认为需进一步研究以确定基于PET的大血管炎治疗能否改善结局。
研究设计与样本
- 系统评价与Meta分析,检索MEDLINE via PubMed和EMBASE中评估F-18 FDG PET或PET/CT检测大血管炎疾病活动性的研究。
- 共纳入9项研究,合计298例患者的439幅PET图像。
- 汇总敏感度、特异度、诊断比值比及sROC曲线,采用Deek漏斗图不对称检验评估发表偏倚。
主要发现
- 检测活动性大血管炎的汇总敏感度为0.88(95%CI 0.79-0.93),无 heterogeneity(χ2=14.42,P=.07)。
- 汇总特异度为0.81(95%CI 0.64-0.91),存在 heterogeneity(χ2=63.72,P=.00)。
- 汇总诊断比值比为30(95%CI 8-107)。
- 分层sROC曲线下面积为0.91(95%CI 0.89-0.94)。
- 无显著发表偏倚(P=.42),meta回归分析显示各变量均非研究异质性的来源。
关键数值与推荐
- 汇总敏感度0.88(95%CI 0.79-0.93),汇总特异度0.81(95%CI 0.64-0.91),用于检测活动性大血管炎。
- 汇总诊断比值比30(95%CI 8-107),sROC曲线下面积0.91(95%CI 0.89-0.94)。
- 发表偏倚检验P=.42,无显著发表偏倚。
临床怎么用
- 原文未据此给出具体临床推荐。
局限性
- 汇总特异度存在 heterogeneity(χ2=63.72,P=.00)。
- 作者认为需进一步研究以确定基于PET的大血管炎治疗能否改善结局。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: The aim of this study is to investigate the performance of F-18 fluorodeoxyglucose positron emission tomography (F-18 FDG PET) or positron emission tomography/computed tomography (PET/CT) for the assessment of disease activity in patients with large vessel vasculitis (LVV) through a meta-analysis. METHODS: The MEDLINE via PubMed and EMBASE were searched for the studies evaluating the performance of F-18 FDG PET or PET/CT in the assessment of disease activity in patients with LVV. Pooled sensitivity, specificity, diagnostic odds ratios (DORs), and summary receiver-operating characteristic (sROC) curve were estimated across the included studies. Possible publication bias was assessed by Deek's funnel plot asymmetry tests. RESULTS: A total of 439 PET images from 298 patients pooled from nine studies showed that the pooled sensitivity was 0.88 [95% confidence interval (CI) 0.79-0.93] without heterogeneity (χ2 = 14.42, P = .07) and the pooled specificity was 0.81 (95% CI 0.64-0.91) with heterogeneity (χ2 = 63.72, P = .00) for the detection of active LVV. The pooled DOR was 30 (95% CI 8-107). Hierarchical sROC curve indicates that the area under the curve was 0.91 (95% CI 0.89-0.94). There was no significant publication bias (P = .42), and meta-regression analysis revealed that none of the variables was the source of the study heterogeneity. CONCLUSIONS: F-18 FDG PET has a good performance for the detection of active disease status in patients with LVV. Revised criteria for the assessment of disease activity incorporated with F-18 FDG PET or PET/CT should be introduced and validated. Further studies are warranted to determine if PET-based treatment of LVV can improve outcomes.
引用
- Lee SW, Kim SJ, Seo Y, et al. F-18 FDG PET for assessment of disease activity of large vessel vasculitis: A systematic review and meta-analysis. J Nucl Cardiol. 2018. PMID: 30120746. doi:10.1007/s12350-018-1406-5
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。