文献速递心脏核医学

使用动态PET-CT和碳-11-间羟基麻黄碱动力学图形建模可重复定量心脏交感神经支配

Reproducible quantification of cardiac sympathetic innervation using graphical modeling of carbon-11-meta-hydroxyephedrine kinetics with dynamic PET-CT imaging.
PubMed 文献 · EJNMMI Res · 2018-07-20

本研究在18例有心衰症状的受试者中,比较Logan和MA1图形模型与标准单组织室模型(1TC)在[11C]HED动态PET-CT中定量左心室心肌交感神经支配的分布容积(VT)。采用t*=5分钟起始时间和部分容积校正时,MA1与1TC一致性良好(ICC=0.96),Logan稍低估VT(p=0.002),两模型重测重复性均良好且无显著差异(p=0.57)。

要点

  • Logan和MA1图形模型与1TC模型一致性良好至优秀(ICC分别为0.93和0.96)。
  • Logan模型较1TC轻度低估VT(p=0.002),MA1与1TC无显著差异(p=0.96)。
  • t*=5分钟为最佳拟合起始时间,部分容积校正后VT可准确反映心肌交感神经支配。

核心结论

  • Logan和MA1模型在[11C]HED动力学建模中与1TC模型一致性和变异性相似。
  • 使用t*=5分钟和部分容积校正可准确估计VT作为心肌交感神经支配的指标。

研究设计与样本

  • 在18例有心衰症状的受试者中进行了[11C]HED动态PET-CT测试与重测(间隔47±22天)。
  • 用Logan和MA1图形模型估计心肌组织分布容积(VT),并与标准1TC模型比较,采用组内相关系数(ICC)和Bland-Altman分析非参数重复性系数(NPC)。

主要发现

  • Logan和MA1模型的最佳拟合起始时间均为t*=5分钟(R2=0.95)。
  • Logan模型相对1TC模型轻度低估VT(p=0.002),MA1模型与1TC模型无显著差异(p=0.96)。
  • MA1与1TC的ICC=0.96,Logan与1TC的ICC=0.93,两者NPC无显著差异(p=0.92)。
  • 所有方法的重测重复性良好至优秀,NPC无显著差异(p=0.57)。

关键数值与推荐

  • Logan与1TC比较:ICC=0.93,VT轻度低估(p=0.002)。
  • MA1与1TC比较:ICC=0.96,VT无显著差异(p=0.96)。
  • Logan与MA1的NPC比较无显著差异(p=0.92);所有方法重测NPC无显著差异(p=0.57)。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Graphical methods of radiotracer kinetic modeling in PET are ideal for parametric imaging and data quality assurance but can suffer from noise bias. This study compared the Logan and Multilinear Analysis-1 (MA1) graphical models to the standard one-tissue-compartment (1TC) model, including correction for partial-volume effects, in dynamic PET-CT studies of myocardial sympathetic innervation in the left ventricle (LV) using [11C]HED. METHODS: Test and retest [11C]HED PET imaging (47 ± 22 days apart) was performed in 18 subjects with heart failure symptoms. Myocardial tissue volume of distribution (VT) was estimated using Logan and MA1 graphical methods and compared to the 1TC standard model values using intraclass correlation (ICC) and Bland-Altman analysis of the non-parametric reproducibility coefficient (NPC). RESULTS: A modeling start-time of t* = 5 min gave the best fit for both Logan and MA1 (R2 = 0.95) methods. Logan slightly underestimated VT relative to 1TC (p = 0.002), whereas MA1 did not (p = 0.96). Both the MA1 and Logan models exhibited good-to-excellent agreement with the 1TC (MA1-1TC ICC = 0.96; Logan-1TC ICC = 0.93) with no significant differences in NPC between the two comparisons (p = 0.92). All methods exhibited good-to-excellent test-retest repeatability with no significant differences in NPC (p = 0.57). CONCLUSIONS: Logan and MA1 models exhibited similar agreement and variability compared to the 1TC for modeling of [11C]HED kinetics. Using t* = 5 min and partial-volume correction produced accurate estimates of VT as an index of myocardial sympathetic innervation.

来源:EJNMMI Res,查看原文。版权归原作者所有。

引用

  1. Wang T, Wu KY, Miner RC, et al. Reproducible quantification of cardiac sympathetic innervation using graphical modeling of carbon-11-meta-hydroxyephedrine kinetics with dynamic PET-CT imaging. EJNMMI Res. 2018. PMID: 30030665. doi:10.1186/s13550-018-0421-5

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。